Basic Info.

Model NO.
YJ-180
Sample Volume
2-100μl , 0.1μl by Step
Assay Items
22 Parameters, 3 Parts Different of Wbc
Reaction Temperature
37±0.2°c
Temperature Fluctuation
± 0.2°c
Heating Method
Solid Constant Temperature Closed Direct Heating
Data Input
Keypad
Power Supply
AC220V±22V, 50±1Hz
Transport Package
Standard Package
Specification
43cm*32cm*50.5cm
Trademark
FORERMED
Origin
China
HS Code
90278099
Production Capacity
5000pieces. Month

Product Description

 
Product Description

 


Factory price fully automatic biochemistry analyzer with open system

Fully Automatic Biochemistry Analyzer with Open System

Throughput constant 180 T/h or 300T/h,best for middle or small size hospital Closed integrated photovoltaic systems, no mechanical parts,maintenance free.

Advantages&features:
Discrete, random access, fully automated
Up to constant 200 tests per hour
Optional for external bar code reader
30 positions for samples and 60 positions for reagents
Automatic probe cleaning, liquid level detection, collision protection
Reversed optic system with 8 wavelengths: 340-670nm
Refrigerated reagent and sample compartment
Test Speed: constant 160tests/hour, up to 220tests/hour
Test method: End-point, Fixed-time (two point method), kinetic
Reaction tray: 81 UV cuvettes (disposable)
Mini reaction volume: 150μl, save reagent cost
Insert emergency at any time
Support linear and non-linear calibration
Heating method: solid constant temperature closed direct heating
Temperature equilibrium time: less than 3minutes,
Reaction Temperature: 37±0.2°C
Temperature Fluctuation: ± 0.2°C
Optical System
Integrated full closed optical system, after spectrometric method, no
mechanical parts, not moldy, no maintenance cost
8 wavelengths, selectable among 340-800nm
Absorption range: 0.00-4.00Abs
Halogen-tungsten lamp has more than 2000hrs service time
Center wavelength deviation: ±2nm, half wave width less than 12nm
Stray light less than 0.3%
Resolution: 0.0001Abs
Reagent/Sample Tray
60 reagent + 30 sample positions
Advanced reagent tray refrigeration system, temperature: 4-12°C (optional
function)
Automatically detect reagent remain, real time display reagent remain
Reagent bottles with 15ml,30ml,50ml,70ml are available.
Support single/ dual reagents, reagents are open
Real time display reagent tray status
Automatically judge substrate depletion
Sample adding and rinsing system
Sample volume: 2-100μl , 0.1μl by step,
Reagent volume: 20-500μl, 1μl by step
Water consumption: less than 3L/hour
Operation System
Windows XP or Windows 7 Home, easy to operate
Automatic storage, automatic backup, no time limit and storage limit,
Permanently preserve all kinds of data
English print report, the user can modify the print format
English online help and operation guide
The test parameter setting is completely open
Real-time monitor the status of sample tray, reagent tray and reaction tray
Real-time monitor the status of reaction cup, lamp and purified water
Real-time display the reaction tray humidity and reagent remain
Real-time display the reaction curve, calibration curve and QC chart
Automatically check calibration curve and select the calibration type with the
best fitting
Calibration Mode: Linear, Logit-4p, Logit-5p, Spline, Factor, Polynomial
Inspection and Judgment: Reaction end point judgment, reaction linear range
judgment, substrate depletion judgment, reaction limit inspection, reagent
blank absorbance judgment
RS232 standard interface, support the intranet and remote printing

 
Company Profile

 


Fully Automatic Biochemistry Analyzer with Open System
 
Customer visits
Fully Automatic Biochemistry Analyzer with Open System
Fully Automatic Biochemistry Analyzer with Open System

Customer feedback
Fully Automatic Biochemistry Analyzer with Open System
Fully Automatic Biochemistry Analyzer with Open SystemFully Automatic Biochemistry Analyzer with Open SystemFully Automatic Biochemistry Analyzer with Open System





Fully Automatic Biochemistry Analyzer with Open System
 Buy Medical Equipments , Best Choose Forever Medical!!!
 
You Choose We Care


 
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now