• High Frequency Diagnostic Equipment Digital Radiography System X Ray Machine
  • High Frequency Diagnostic Equipment Digital Radiography System X Ray Machine
  • High Frequency Diagnostic Equipment Digital Radiography System X Ray Machine
  • High Frequency Diagnostic Equipment Digital Radiography System X Ray Machine
  • High Frequency Diagnostic Equipment Digital Radiography System X Ray Machine
  • High Frequency Diagnostic Equipment Digital Radiography System X Ray Machine

High Frequency Diagnostic Equipment Digital Radiography System X Ray Machine

Classification: Imaging Diagnostic Equipment
Type: X Ray Equipment
Certification: CE, ISO13485
Output Power: 50kw
Power Voltage: 380V±38V
Kv Range: 40~150kv
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
YJ-7300D
Ma Range
10~630mA
Wire Flat Panel Detector
17*17inch
X-ray Tube
0.6
Computer LCD
23inch
Transport Package
Wooden Case Packing
Specification
50KW 10~630mA
Trademark
FORERMED
Origin
China
Production Capacity
50 Cartons Per Month

Product Description

Product Description

High Frequency Diagnostic Equipment Digital Radiography System X Ray MachineHigh Frequency Diagnostic Equipment Digital Radiography System X Ray Machine
Features


The floating table with bucky stand can meet the photographic requirements of different standing and lying positions. The bed floating and electromagnetic lock design makes it convenient for the accurate position of the lying patient, operation is much more convenient and flexible.

The 17" *17" digital flat Panel detector can help you get the high-definition images.
The leading domestic high power compact high frequency Xray generator and high frequency power inverter makes the machine much more compact and more convenient without the extra high-voltage generator and cable.
The application of the KV and MA digital closedloop control technology and the real time control of the microprocessor ensure the accuracy and repeatability of the dose.
The multiple automatic protection  features  and  fault tips  ensure  safety  during the  operation process.
Ultra high inverter frequency 440kHz make sure the best X-ray stability and continuity.

Configurations:

 

Part Name Qty Note
HF HV generator 1 set PLD
X-ray tube assembly 1 unit Toshiba
Collimator 1 unit PLD
Radiography Table 1 unit PLD
Bucky Stand 1 unit PLD
Flat Panel Detector 17*17 inch 1 set PLD
Image acquisition Workstation 1 set PLD
Computer +19"LCD monitor +key board+mouse 1 set PLD
Working Station Operation Table 1 set PLD
Cables etc accessories 1 set PLD


Main Technical Parameters:
 
Item Content Technical Parameter



Power Supply
Voltage 380V +-38v
Frequency 50Hz+- 1Hz
Capacity 65kVA
internal resistor ≤0.17Ω



Generator
  Power Output 56KW
Inverter Frequency 440 KHz

photogra
phy
Tube Voltage 40kV- 150kV
Tube Current 10mA-710mA
Exposure time 1.0ms- 1000ms
Digital Controlled X-ray
Tube
Tube  Focus:Large  Focus/Small Focus 1.2mm /0.6mm
Input Power Big focus 75kW /    Small Focus 27kW


 
  Anode thermal capacity 210KJ
Tube heat capacity 900KJ
Rotary anode speed 9700rpm/min





Radiography Table
Table longitudinal movement ≥900mm
Table transverse movement ≥220mm
Pillar movement along table ≥1300mm
Detecting holder movement ≥500mm
Tube assembly up-down
movement
500mm~1280mm
Collimator Manual Multi-leaf
Table use fixed grid Grid    density    103L/INCH,    grid    10:1 SID: 120cm, fixed model: 15″×18″


Bucky Stand
Radio-graphic                   device
movement along pillar
≥1300mm
Cassette SID: 450  ~1780mm
Fixed grid: Grid density  103L/INCH,  grid  10:1    ; SID 180cm;Size: 15″×18″




Flat Panel Detector
Vision size:                 427mm(H)×427 mm(V)
Pixel Matrix:                    3072(H)×3072(V)
Pixel gap:139 μm
Imaging time:less than 10s
Limiting resolution:3.1 lp/mm typ
A / D transform:14 bit
Energy range:40 - 150 kVp







Work Station







CPU System
Brand: DELL
Processor:Core™ i5
RAM:4GB
Hardware:1TB    SATA (7200 rpm)
CD-driver:suit MT's 16X variable-speed    DVD + / - RW With functions of double written
Network       Card:       Broadcom       NetXtreme
10/100/1000 PCIe Gigabit LAN GNTB-A
, High display card: 2GB AMD RADEON HD 7570,FH,with DVI-VGA Adapter
Slop:  PCIE  seriel  port   and  parallel  port,  all height, MT

 

Color LCD Monitor
19 inches  1M LED backing light LCD display, revolution 1280x1024 ,5:4screen ,dot  pitch: 0.294mm,   contrast   ratio:   1000:1,   brightness: 250cd, Grey feedback time:5ms




















Work Station Software
Basic operation: change control console
password, edit ID, acquisite images.
Additional operation:Add new check, edit
present checking info, add new position, change
image aquisition order, multi-checking
agreement chance, manual adjustment of
exposure parameters, automatic exposure control mode, focus choice, patient body-type choice,
tube capacity check, ESA curve choice, image
cutting, note added (sent to DICOM
workstation) , mark on images, rotate or
overturn, full-size image observation, check patient info and dose info, accept or refuse   images.
Image management: change order, patient basic info editing, inquiry history images, resend
history images, re-print history images, check images mark info, review history images,
manage refused images, space reclaimed, image protection, and manual image deletion etc.
System management:ID edition, change ID password, ED refrigeration set,statisticsinfo
checking, detector calibration, equipment control, output order management, image
measurement.

High Frequency Diagnostic Equipment Digital Radiography System X Ray Machine

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now