3 Larser Sinocyte Scientific Research Flow Cytometer Analyzer

Certification: CE, FDA
Product Name: Auto Flow Cytometry
Laser Configuration: up to 3 Lasers 405nm(100MW),488nm(60MW),638nm(80MW
Instrument Resolution: <2%
Fluorescence Detectian Limit: Fitc< 50mesf;PE< 30mesf;APC< 30mesf
Fluorescence Linearity: 2-0.99
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Trading Company
  • Overview
  • Product Description
  • Technical specification
  • Detailed Photos
Overview

Basic Info.

Model NO.
YJ-sinocyte
Detector
Apd Detector
Carryover Rate
<0.1%
Detecticn Speed
>50000 Events/S
Signal Range
Maximum10
Transport Package
Standard Importing Cartons
Trademark
sinocyte
Origin
China
HS Code
9018129100
Production Capacity
3000pieces/Month

Product Description

Product Description

Automatic Flow cytometry 

3 Larser Sinocyte Scientific Research Flow Cytometer AnalyzerConfiguration upgrade
Up to 3 lasers and 15 fluorescent channels are configured.with a maximum of 18 detection parameters

Powerful function
High resolution, high sensitivity and high stability

Automatic
Full-automatic detection process, synchronous collection/analysis

Quick loading
Up to 50000 events/s injection speed, greatly improving injection efficiency

Injection options
The automatic sampler supports 40 tubes auto sampler/96holes plate, which is simple and efficient

Fluorescence sensitivity of Rainbow calibration particles(8 peaks):
FITC<50MESF,PE<30MESF,APC<30MESF

3 Larser Sinocyte Scientific Research Flow Cytometer AnalyzerResolution of Rainbow fluorescent particles:
Cv<2%
New elliptical spotlaser
The external beam shaping of the laser is extremely simple. The polychromaticlaser beam shares a focus lens, and the optical path is stable and reliable.
New WDM beam splitter module
Only one dichroic filter is used in each WDM, and the subsequent spectralseparation is based on the transmission characteristics of the band-pass filterinside the band and the reflection characteristics of the band-pass filter outsidethe band, which not only reduces thenumber offilters used, but also reducesthe energy loss, and further improvesthe fluorescence detection sensitivity
Plunger pump sample injection system
Precise sample injection ensures theaccuracy of absolute counting by volume method
New automatic sampler with mixing function
40-tube Rotary/96-well microplate
High efficiency
40-tube Rotary can be tested within 30mins96-well microplate can be tested within 40mins
New automatic sampler with mixing function
40-tube Rotary/96-well microplate

High efficiency
40-tube Rotary can be tested within 30mins96-well microplate can be tested within 40mins

Oncology and Hematology
 
Analysis of 6-color human peripheral bloodimmune cell subsets
Analysis of 9-color human peripheral bloodimmune cell subsets
Detection of dendritic cells (DC)
Phenotypic characterization of natural killercell(NK) populations
Characterization of PBMC T cell receptors
Detection of CD62P Platelet Activation
Immunology
 
Detection of T cell proliferation(CFSE)
Detection of B-cell antibody class
Nk cell-mediated clearance of spleen cells
Detection of Treg cell subsets
Stem cells
 

Flow cytometry analysis of hematopoieticstem cells from mouse bone marrow
Detection of CAR-T extracellular tumor killing
Analysis of mesenchymal stem cells frombone marrow and endometrium of miceFlow cytometry analysis of mousehematopoietic progenitor cells

 

 

Technical specification

Name Main parameter indicators
Laser configuration Up to 3 lasers 405nm(100mW),488nm(60mW),638nm(80mw)
Instrument resolution <2%
Fluorescence detectian limit FITC< 50MESF;PE< 30MESF;APC< 30MESF
Fluorescence linearity 2-0.99
Detector APD Detector
Forward scatlered light resolufon <0.45μm
Detection particle range 0.2-50μm
Carryover rate <0.1%
Absolute count Compatible with volumetric and microsphere absolute counting
Detecticn speed >50000 events/s
Signal range Maximum10
Injection speed Low: 15μL/min: Medium: 30μL/min;
High 1: 60μ L/min;High 2:90u L/min; High 3:120μL/min
Adjustable speed range:15-120 μ L/min
Threshold setting Supports dual thresholds to minimize cell debris
Fucresoence compensabion Suocort automatic online compensation, offine compensation and visual
compensation tools
Project template Support project template function, one-click calling of acquisition
conditiorisMiuoresceince compensation information
Instrument quality contro Automatic daily QC inspection, tracking and recording through Levery-Jennings
lnjection mode Single tube manual sampling
  40 tubes auto sampler with single sample mixing function
  96-hole plates
Software English interface, support acquisition and analysis at the same time
File format Support FCS3.1/FCS3.0 and FCS2.0 format files
Mainterance method Startup initialization,startup cleaning, cleaning between experiments,
shutcwn cleaning.exhaust bubble.etc
  Aulomatic maintenance procedure for monthly cleaning (deep cleaning)
Computer configuration DELL/CPU 15/Memory 8G/HDD 1T/27 inch monitor
Size and weight 760mm*450mm*470mm(length"widththeight),40KG

Detailed Photos

3 Larser Sinocyte Scientific Research Flow Cytometer Analyzer
3 Larser Sinocyte Scientific Research Flow Cytometer Analyzer
3 Larser Sinocyte Scientific Research Flow Cytometer Analyzer
3 Larser Sinocyte Scientific Research Flow Cytometer Analyzer

RELATED PRODUCT

3 Larser Sinocyte Scientific Research Flow Cytometer Analyzer
3 Larser Sinocyte Scientific Research Flow Cytometer Analyzer

 

More informations, welcome to contact with us

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now