Classification: | Physiological Functions of Diagnosis and Monitoring Equipment |
---|---|
Type: | Patient Monitor |
Certification: | CE, ISO13485 |
Group: | Infants and Young Children |
Name: | Fetal Monitor |
Display: | 12.1" Color TFT LED |
Customization: |
---|
Suppliers with verified business licenses
CTG machine Maternal Fetal Monitor for Pregnant Women
Performance Specifications
|
|
Dimension and Weight
|
- Dimension: 360mm*310mm*120mm - Weight: 5.3kg(excluding accessories) |
Power Supply
|
- Voltage: AC100~240V, 50/60HZ
|
Display
|
- 12.1" color TFT LED (0-90° rotation) - Resolution: 1024*768 pixels |
Battery (Built-in)
|
- Type: Rechargeable lithium battery 14.8V/2200mAh - Charge Cycle: ≥500 times - Working time: 2 hours |
Recorder (Built-in)
|
- Method: Thermal printer - Paper: Z-fold, thermosensitive - Paper width: 112 mm (4.41 in)/150 mm (5.91 in) - Printing speed: 1/2/3cm/min - Trace: Max. 4 tracks - Recording way: Real-time Recording, Review Printing |
Alarm
|
- Level: Low, medium and high - Indication: Auditory, Visual, Delay of FHR Alarm |
Input Device
|
- Touch screen (option) - Knob (Standard) - Keypad input (Standard) - Mouse/ Keyboard input (option) - USB port for patient data/NST report backup(option) |
System Output &Extensible Interface
|
- Ethernet Network: 1 standard RJ45 socket - USB Port: 2 - Video Output: 1 HDMI port (option) |
Trend & Reviewing
|
- Cardiotocography (CTG): Waveform Review: 8640 hours - Vital Signs: Trend: 2160 hours Waveform Review: 2 hours NIBP Review: 2000 groups - Alarm Review: 2000 groups |
Safety
|
- IEC60601-1 Approved, CE marking according to MDD93/42/EEC - With reference to RoHS Directive 2011/65/EU recasting |
Ultrasound (FHR)
|
- Transducer type: 12-Crystal ultrasound transducer - Measure method: Wide beam pulse doppler - FHR Measurement range: 30 to 240 bpm (US Standard) 50 to 210 bpm (Europe Standard) - Accuracy: ±1 bpm - Intensity: <3 mW/cm2 - Ultrasound frequency: 1MHz±3% - Resolution: 1 bpm |
TOCO
|
- Measurement method: Strain gauge sensor element - Measure range: 0 ~ 100 units - Resolution: 1 unit - Nonlinear deviation : ≤±8% - Baseline setting: 0,5,10,15, 20 can be selected - Auto offset correction: 3 second after connecting the transducer - Auto zero adjust: TOCO value is set to zero negative following a negative Measure value for 5 seconds |
Fetal Movement Recording
|
- Automatic fetal movement (AFM): pulsed doppler ultrasound - Automatic fetal movement autograph - Manual fetal movement marker (MFM) |
Maternal ECG
|
- Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V - Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV, Auto - Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50 mm/s - Accuracy: ±1bpm/ ±1%, whichever is greater - Resolution: 1 bpm - Leakage Current < 10 μA - CMRR: Diagnostic Mode >89 dB Monitor Mode >105 dB Surgery Mode >105 dB - Bandwidth: Surgery 1 ~ 25 Hz Monitor 0.5 ~ 40 Hz Diagnostic 0.05 ~ 120 Hz |
Maternal Heart Rate
|
- Measure range: Adult: 0bpm; 10 ~ 300 bpm Neonate: 0bpm; 10 ~ 350 bpm - Resolution: 1 bpm - Accuracy: ± 1% or ± 1bpm, whichever is greater |
ST Measurement
|
- Range: -2.0 ~ +2.0 mV - Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, whichever is greater - Other range: unspecified
- Resolution: 0.01mV
|
Maternal Respiration
|
- Method: Impedance between RA-LL, RA-LA - Gain: ×0.25, ×0.50, ×1, ×2, ×4 - Respiration Rate: 0bpm, 6 ~ 150 bpm - Resolution: 1 bpm - Accuracy: ±2 bpm or ±2%, whichever is greater - Apnea Alarm: 10 ~ 60 s |
Maternal SpO2 (Digital Technic)
|
- Measurement Range: 0 ~ 100 % - Resolution: 1 % - Accuracy: ±2% (70% ~ 100%) ±3 % (35% ~ 69%) Unspecified (0 ~ 34%) |
Pulse Rate
|
- Range: 25~250bpm - Accuracy: ±1% or ±1 bpm, whichever is greater - Resolution: 1bpm |
Maternal NIBP (MNIBP)
|
- Method: Oscillometric - Measure mode Manual, Auto, STAT - Measure Interval in AUTO Mode 1~480 min - STAT mode cycle time: - Keep 5 minutes, at 5 seconds interval - Measure and Alarm Range: Systolic: 30~270 mmHg Diastolic: 10~220 mmHg Mean: 20~235 mmHg - Static pressure accuracy ±3mmHg - Resolution: 1mmHg - Accuracy: Maximum Mean error ±5mmHg Maximum Standard deviation 8mmHg - Over pressure Protection: Dual protection via software & hardware |
Maternal Temperature
|
- Technique: Thermistor probe (2.25K) - Measuring and Alarm Range: 0.0 ºC~ 50 ºC (32ºF~ 122ºF) - Unit: Celsius (ºC), Fahrenheit ( ºF) - Resolution: 0.1ºC - Accuracy: ±0.1ºC |
12.1 inches Fetal Monitor Model
|
Config. A
|
Config. B
|
Config. C
|
Config. D
|
|
Fetal Parameter
|
Single FHR
|
*
|
*
|
*
|
*
|
Dual FHR
|
N/A
|
*
|
N/A
|
*
|
|
TOCO
|
*
|
*
|
*
|
*
|
|
AFM & MFM
|
*
|
*
|
*
|
*
|
|
Signal Overlap Alarm
|
N/A
|
*
|
*
|
*
|
|
Maternal Parameter
|
NIBP, SpO2, PR
|
N/A
|
N/A
|
*
|
*
|
ECG, TEMP, RESP
|
N/A
|
N/A
|
*
|
*
|
|
Printer Paper Width
|
112mm A type
|
Opt
|
Opt
|
Opt
|
Opt
|
112mm B type
|
Opt
|
Opt
|
Opt
|
Opt
|
|
150mm A type
|
Opt
|
Opt
|
Opt
|
Opt
|
|
150mm B type
|
Opt
|
Opt
|
Opt
|
Opt
|
|
Battery
|
Lithium battery
|
*
|
*
|
*
|
*
|
Option:
|
1) HDMI
|
||||
2) Touch Screen
|
|||||
3) Fetal Stimulator
|
|||||
4) Wall-mount
|
|||||
5) Trolley
|
|||||
6) Waterproof FHR Probe & TOCO Probe
|
|||||
7) Central Monitoring Station
|
|||||
8) Keyboard & Mouse control function
|
|||||
9) Advanced Fischer NST Report
|
|||||
10) USB port with patient data/NST report backup function
|
|
||||
Remark: The touch screen and mouse/ computer keyboard is not compatible by now.
|
|||||
Table legend: : Standard , N/A - not applicable
|
1.FHR Transducer
2.TOCO Transducer
3.Event Marker
4.Fetal Acoustic Stimulator
5.Central Monitoring Station
6.Reusable Transducer Belt
7.NIBP Cuff and NIBP Tube
8.SpO2 Transducer
9.Temperature Transducer (Skin / Rectal type)
10.ECG Cables
11.Wall-mount with basket
12.Trolley with Basket
13.112(A) mm Thermal Paper (112mm×100mm×150p,European Standard, 30-210 bpm)
14.112(B) mm Thermal Paper (112mm×100mm×150p, USA
Standard, 30-240 bpm
15.150 (A) mm Thermal Paper (150mm×100mm×150p, European Standard, 50-210bpm)
16.150 (B) mm Thermal Paper (150mm×100mm×150p, USA Standard, 30-240bpm)
Suppliers with verified business licenses