This product is no longer promoted on Made-in-China.com. If you find any infringement or sensitive information of it, please contact us for handling. Thank you.
  • Hospital Laboratory Clinical Chemistry and Biochemistry Analyzer
  • Hospital Laboratory Clinical Chemistry and Biochemistry Analyzer
  • Hospital Laboratory Clinical Chemistry and Biochemistry Analyzer
  • Hospital Laboratory Clinical Chemistry and Biochemistry Analyzer
  • Hospital Laboratory Clinical Chemistry and Biochemistry Analyzer
  • Hospital Laboratory Clinical Chemistry and Biochemistry Analyzer

Hospital Laboratory Clinical Chemistry and Biochemistry Analyzer

Diamond Member Since 2017

Suppliers with verified business licenses

Trading Company
  • Overview
  • Product Description
  • Technical specifications
  • Our Company
Overview

Basic Info.

Model NO.
YJ-180
Minimum Reaction Volume
150 UL
Maximum Reaction Time
15 Minutes
Classificatio
Biochemical Apparatus
Customized
OEM, Customized
Transport Package
Standard Exporting Safe Package
Specification
782mm*581mm*545mm
Trademark
Forever Medical
Origin
China
HS Code
90278099
Production Capacity
300 Sets/ Month

Product Description

Product Description

Reagent/Sample handing Unit


1. Intelligent liquid detection & collision protection
(Red light: collision; Blue light: detection of the liquid).
2.  Reagent volume: 2 ~ 500μl,step by 1μl .
3.  Probe cleaning:automatically washing for both inside and outside,carry over0.1%.
4. Automatically dilute and retest.

Calibration and Quality Control Unit

1. Linear curve type:Single-point linear,two-point linear and multi-point linear.
2. Nonlinear curve type:Logit-4p,Logit-5p,polynomial,factor.
3.  Automatically use best calibration curve and standard.
4.  Quality control chart:L-J,Westgard TwinPlot,Cumulative.

Operation Unit 

1.  Operation system:
Windows XP/Office 2000,interface is intuitive and operate it easily, arbitrary operating authority;No restrictions on the amount of time and storage, permanent preservation of various types of data, automatic storage and backup.
2. Can print the contents of any custom;Offers a variety of print formats.
3. Help and operation guide on line in English.
4. No restrictions on setting test parameters.
5. Unique password for user management,rational allocation of user rights.
6. Real time display of testing status,the remaining amount of reagent,testing status ,reaction curve and the test progress.
7. Real time display of reaction plate temperature.
RS-232 standard interface,support for the hospital network, print reports remotely.
 

Test Projects

1. ALT,AST,TP,ALB,TBIL,DBIL,ALP,r-GT,CHE,TBA,5-NT
2.  UREA,CR,UA,TCO2
3. CHOL,TG,HDL,LDL,ApoA,ApoB,LPa
4. AMY,LIP
5. GLU,GSP
6. CK,CK-MB,a-HBDH,LDH,MB
7. CRP,RF,ASO
Technical specifications

 

Model YJ-180
Analyze Unit Throughput Constant 180T/h (non-ISE)
Theory Absorption spectrometry, transmission turbidimetry
Methodology End-point \Fixed-time\Kinetic\Ion selective electrode
Test according set up, random access Reaction plate Contain 81 reaction cuvettes
Maximum reaction time 15 minutes
Minimum reaction volume 150 ul
Material of cuvettes Special UV-transparent optical glass
Cuvettes use Automatically cuvettes washing
Optical Unit Light Source Halogen-tungsten lamp
Photometer Reversed optics
Wavelength 340nm-900nm wavelength option
Absorption 0-4 Abs
Reagent Unit Reagent plate 60 reagent positions ,support for single and double reagent, reagent completely open
Reagent storage temperature 2~10 degree
Reagent bottle 15ml, 20ml, 30ml, 50ml or 70ml ,dead volume is less than 1.0 ml
Reagent volume 20-500 ul, step by 1.0 ul
Reagent/Sample Probe Automatically checked ;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside.
Sample Unit Sample plate 60 sample positions
Sample type Human (animal) serum \plasma\urine etc.
Samples cup Support one-off micro cups
Sample volume 2-100 ul, step by 0.1 ul
Sample/reagent probe Automatically checked ;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside.
Temperature control Unit Heating method Direct thermal solid thermostat closed
Temperature equilibrium time <3 minutes
Reaction temperature 37 ±0.1 degree
Temperature fluctuation ±0.1 degree
Operation Unit Software WindowsXP \2000
Database SQL Server
Data Storage Automatic store & copy; No time and volume limit; Lifetime preservation
Print format Can be set up, offer several standard format
Calibration mode Linear curve type: Single-point linear, two-point linear and multi-point linear none linear; Curve type: Logistic-Log 4P,Logistic-Log5p,Spline,index automatically use best calibration curve and standard
Quality control methods : Real time, within day & between day
Quality control diagram L-J \cumulative\twin plot
Status display Real time monitoring of reagent residual volume .Running status of reagent tray, samples tray
Adjustment Dynamic and real time display of running status; Intelligent carry over settings to adjust test sequence; original reaction data record; Detail profile of alert messages       
Setting Operation permission setting, Item setting, cross pollution setting, cuvette blank setting
Others Water consumption : < 6L/h Power Supply :AC 220V±22V 50Hz±1Hz
Frequency :Maximum 600VA Dimension :782mm×581mm×545mm
Net Weight : 60kg Accessory : Software Note:We provides you with 12-24 months free repair guarantee for main unit, 12 months free repair guarantee for probe and 6 months free repair guarantee for the optional parts respectively.More information for our products and service,please turn to our official website or contact us directly.
 