• Full Digital Laptop Ultrasound System Caidiac Ultrasound Scanner
  • Full Digital Laptop Ultrasound System Caidiac Ultrasound Scanner
  • Full Digital Laptop Ultrasound System Caidiac Ultrasound Scanner
  • Full Digital Laptop Ultrasound System Caidiac Ultrasound Scanner
  • Full Digital Laptop Ultrasound System Caidiac Ultrasound Scanner
  • Full Digital Laptop Ultrasound System Caidiac Ultrasound Scanner

Full Digital Laptop Ultrasound System Caidiac Ultrasound Scanner

Classification: Imaging Diagnostic Equipment
Type: Ultrasound Scanner
Certification: CE, ISO13485
Group: Middle-aged and Old
Name: Portable Ultrasound Scanner
Keyboard: Light Floating International Standard
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Trading Company
  • Overview
  • Product Description
  • Technical specifications
  • Clinical Images
  • Detailed Photos
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
YJ-P8
Probe Transducer Types
3.5 MHz Convex Probe
Zoom
10 Steps
Focus
Continuous Dynamic Focus
Memory
Cine Memory
Calculation
Abdomen Urology Gynecology Musculoskeletal
Power
AC 100V to 240V
Screen
15 Inch High Resolution LED& Monitor
Atmospheric Pressure
700hpa to 1060hpa
Transport Package
Standard Importing Cartons
Specification
Portable Ultrasound Scanner
Trademark
FORERMED
Origin
China
HS Code
9018129100
Production Capacity
3000pieces/Month Ultrasound Scanner

Product Description

Product Description

Caidiac Ultrasound-YJ-P8
Fully image FunctionHigh Quality Clinical  Performance
Full Digital Laptop Ultrasound System Caidiac Ultrasound Scanner
 
Ingenuity Serve The Sound
Full Digital Laptop Ultrasound System Caidiac Ultrasound Scanner

Full Digital Laptop Ultrasound System Caidiac Ultrasound Scanner
Full Digital Laptop Ultrasound System Caidiac Ultrasound Scanner

Technical specifications

 

1. Product name: Full digital color Doppler ultrasound diagnostic instrument
2. Purpose description and cargo requirements:
2.1 Meet the basic hospital in the abdomen, obstetrics, gynecology, heart, urinary system,
small organs, superficial, blood vessels, pediatric, neonatal, muscle, physical examination
and other aspects of examination and diagnosis
3. System technical specifications and overview
3.1. Full digital color Doppler ultrasound diagnosis system host
3.2. Digital beam intensifier
3.3. Multiple beam synthesis
3.4. 2D gray scale mode
3.5. Harmonic imaging technology
3.6.B+C dual real-time mode
3.7.M mode
3.8. Dissecting M mode, sampling lines ≥3
3.9. Doppler imaging (including color, energy, and directional energy Doppler modes)
3.10. Spectrum Doppler imaging (including pulse Doppler, high pulse repetition rate, continuous wave
Doppler)
3.11. Tissue Doppler imaging (including tissue velocity map, M mode, spectral imaging, etc.)
3.12. 4D imaging
3.13.★ Contrast imaging technology (optional)
3.14.★ Equipped with PView panoramic imaging technology (optional)
3.15. Spatial composite imaging technology (applicable to abdomen, obstetrics, blood vessels, superficial small
organs, dual-amplitude contrast display with the screen)
3.16. Frequency composite imaging
3.17. Extended imaging
3.18. Real-time double contrast imaging
3.20. Real-time tri-synchronous imaging (2D, color and spectral real-time synchronous imaging)
3.21. Speckle noise suppression technology
3.22. Elastography imaging Technology (optional)
4. Operation interface: The host contains 10 operation language interfaces.
5. System technical parameters and requirements
5.1 Standard color LCD ≥15 inches
5.2 ★ Host built-in probe port ≥2, fully activated, consistent in size, interoperable
5.3. 2D gray scale mode
1) Digital beam generator
2) Digital whole process dynamic focus, digital variable aperture and dynamic trace, A/D≥15 bit
3) Receiving mode: Transmitting and receiving channels ≥1024, multifold signal parallel processing
4) Scanning line: the line density of each frame is ≥512 ultrasonic line
5) Emitting acoustic beam focusing: The emission ≥10 segments, and the focus position has special menu
adjustment
6) TGC≥8 segments
7) Gain adjustment: B/M/D is independently adjustable, ≥100dB
8) ★ Dynamic range adjustment: ≥180dB
8) ★ Maximum display depth ≥360mm
9) Grey level: ≥67, adjustable in sight
10) Sound power: 1%-100%
11) 2D independent deflection of linear probe
12) Local magnification (1.5/2.0/2.5/3.0/3.5, 4.0/4.5/5.0/10 times)
5.4. Color Doppler imaging
1) Imaging mode: including speed, velocity variance, energy, direction energy display, etc
2) Display mode: B/C, B/C/M, B/POWER, B/C/PW
3) Line density ≥ level 3
4) Color hiding technology: Color can be hidden without going back to 2D mode, and only color speed scale
can be displayed
5) Function of blood flow profile, color blood flow profile to measure the velocity inside the blood vessel
5.5. Spectral Doppler mode
1) Display format: full screen, duplex/triplex (PW only)
2) Gain: ≥100dB
3) Multi-spectral speed: adjustable ≥4 levels
4) Maximum measurement velocity: PWD: positive or reverse flow velocity ≥7.6m/s; CWD: Flow velocity
≥20.0m/s, minimum velocity: ≤ 5mm /s (non-noise signal);
5) Zero movement: ≥8 level
6) Display mode: B, PW, B/PW, B/C/PW, B/CW, B/C/CW, etc
7) Automatic and manual measurement of the spectrum
8) Display control: reverse, zero shift, B refresh, D extension, B/D extension, etc
9) Intelligent Doppler technology can switch freely between real-time B+CFM mode and real-time PW mode. 5.6. 4D mode:
1) Four-dimensional imaging mode: surface mode, maximum mode, minimum mode, perspective mode, etc
2) Display mode: single, double and four. 3) Cropping function. 4) Level 1-509:10 of transparency is adjustable
5) threshold 0-129
6) smooth≥4
7) 4D format to store pictures, movies and body data
5.7.★ Standard panoramic imaging (optional)
1) Under high resolution, the maximum display length can reach 50cm
2) Forward writing can be supported during imaging without re-imaging
3) Equipped with 2D and color panoramic imaging modes
5.8.★ Enhanced puncture function (linear probe) (optional)
1) The angle and position of puncture needle can be adjusted
2) It has two guidance modes: puncture line and puncture guidance range
5.9. Probe ports ≥4, all activated. Volume probe plug and play.
5.10. Probe: Broadband frequency conversion probe, 2D and color independent frequency conversion, 1) Abdominal probe: convex, ultrasonic frequency 2.0-5.4mhz
2) Small organ superficial probe: linear, ultrasonic frequency 4.0-13.3mhz
3) Trans-vaginal probe: micro-convex, 5.0-9.0mhz, conventional scanning angle ≥160°. 4) Probe configuration: 1 convex probe and 1 superficial high-frequency probe; It can be equipped with
phased-array cardiac probe, trans-vaginal probe and abdominal 4D probe. 5) Requirements for linear probe: number of array elements: 80 array elements (optional 128 array elements);
6) Fundamental wave frequency conversion of the probe ≥3 segments;
7) 1. The convex probe: fundamental frequency: 2.0 MHz / 2.3 MHz / 2.5 MHz / 3.0 MHz / 3.5 MHz / 4.0
MHz / 4.6 MHz / 5.0 MHz / 5.4 MHz, nine frequency conversion
Harmonic frequency: 4.0mhz / 4.6mhz / 5.0mhz, three frequency conversion
2. Linear probe: fundamental frequency: 4.0 MHz / 4.6 MHz / 5.0 MHz / 6.0 MHz / 7.0 MHz / 8.0 MHz / 9.2
MHz / 10.0 MHz / 12.0 MHz / 13.3 MHz, nine frequency conversion
Harmonic frequency: 8.0mhz / 9.2mhz / 10.0mhz, three frequency conversion
3. Trans-vaginal probe: Fundamental frequency:
3.0 MHz / 3.5 MHz / 4.0 MHz / 5.0 MHz / 5.4 MHz / 6.0 MHz / 7.0 MHz / 8.0 MHz / 10.0 MHz, nine
frequency conversion
Harmonic frequency: 6.0mhz / 7.0mhz / 8.0mhz, three frequency conversion
4. The phased array probe: fundamental frequency: 1.7 MHz / 1.9 MHz / 2.1 MHz / 2.5 MHz / 3.0 MHz / 3.4
MHz / 3.8 MHz / 4.2 MHz / 5.0 MHz, nine frequency conversion
Harmonic frequency: 3.4mhz / 3.8mhz / 4.2mhz, three frequency conversion
5. High frequency phased array probe: fundamental frequency: 3.0 MHz / 3.5 MHz / 4 MHz / 5
MHz / 5.4 MHz / 6 MHz / 7 MHz / 8 MHz, eight frequency conversion
Harmonic frequency: 6MHz/7MHz/8MHz, three frequency conversion
6. Volume probe: the fundamental frequency: 2.0 MHz / 2.5 MHz / 3.0 MHz / 3.3 MHz / 3.7 MHz
/ 4.0 MHz / 5.0 MHz / 6.0 MHz, eight frequency conversion
Harmonic frequency: 4.0mhz / 5.0mhz / 6.0mhz, three frequency conversion
7. Micro-convex probe: fundamental frequency: 3.0 MHz / 3.5 MHz / 4.0 MHz / 5.0 MHz / 5.4 MHz
/ 6.0 MHz / 7.0 MHz / 8.0 MHz, eight frequency conversion
Harmonic frequency: 6.0mhz / 7.0mhz / 8.0mhz, three frequency conversion
8. visual abortion probe: fundamental frequency:
3.0 MHz / 3.5 MHz / 4.0 MHz / 5.0 MHz / 5.4 MHz / 6.0 MHz / 7.0 MHz / 8.0 MHz / 10.0 MHz, nine
frequency conversion
Harmonic frequency: 6.0mhz / 7.0mhz / 8.0mhz, three frequency conversion
Note: According to customer's needs, it can be equipped with convex probe, linear probe,
trans-vaginal probe, micro-convex probe, phased array probe, volume probe, visual abortion
probe
5.11. Technical requirements of electronic convex probe: Frequency range: 2.0-5.4mhz, lateral
resolution: ≤2 (depth ≤80), ≤3mm (depth ≤130) axial resolution: ≤1 (depth ≤80), ≤1mm
(80 < depth ≤130) blind area: ≤3mm Geometric position accuracy: Transverse: ≤5%;
Longitudinal: ≤5%. Detection depth ≥ 240mm.
5.12. Technical requirements of electronic linear probe: frequency range: 4.0-13.3mhz, lateral resolution: ≤1
(depth ≤40), axial resolution: ≤0.5 (depth ≤50), blind area: ≤3mm, geometric position accuracy:
transverse: ≤4%; Longitudinal: ≤2%. Detection depth ≥ 100mm.
6. Measurement/analysis and reporting:
6.1 Conventional measurement: distance, area, ellipse, reticle, angle, distance ratio, volume,
volume (ellipse), area ratio, diameter, joint angle.
6.2 Specialist special measurement
1) cardiac measurements: automatic spectrum envelope, left ventricle, main pulmonary artery
diameter, RVEDd, RVEDs, left ventricular muscle, left, HR, mitral valve blood flow volume,
aorta, aortic regurgitation and left ventricular outflow tract, tricuspid valve and pulmonary
valve and pulmonary vein blood flow, right ventricle, doppler cardiac sound, left ventricular
ejection time, left ventricular myocardium, left ventricular myocardial performance index,
the aortic valve
2) Vascular measurement: carotid intima (IMT), length stenosis ratio, area stenosis ratio,
IMT (posterior wall), IMT (anterior wall)
3) ★Obstetric measurements: obstetric measurements and analysis, contrast analysis of the
has 2 or more children, fetal growth curve display, fetal anatomic structure description, fetal
physiology scoring, automatic NT measurement, fetus, amniotic fluid index, fetal weight,
gestational sac, head butt diameter, the forehead after long, humerus, ulna, neck pillow size
transparent layer, fibula, nasal bone length, long radius, the tibia
4) Gynecological measurement: uterine, cervix, uterine body/cervix, left ovary, right ovary,
dominant follicle, uterine body, endometrial thickness
5) Urinary measurement: prostate, residual urine, left kidney, right kidney, left adrenal
gland, right adrenal gland, left testis, right testis, left seminal vesicle and right seminal
vesicle
6) Abdominal measurements: liver, common hepatic duct, portal vein diameter, gallbladder,
common bile duct, pancreas, spleen, abdominal aorta diameter, kidney
7) Small organ: thyroid
7. Peripheral Parts:
7.1. Equipped with a set of ultrasound graphic workstation, the workstation software shall
have registration certificate, supporting digital black and white, analog black and white,
digital color, analog color, text and video printers, and supporting foot switch.
7.2 Support network connection
7.3 Support DICOM 3.0 DICOM obstetrics and gynecology, heart, blood vessels report
7.4 Video/audio input and output
7.5 The host comes with USB interface
7.6 Support the ultrasound system to send clinical pictures and reports directly to the computer
through the network
8. Movie playback and raw data processing:
8.1 Movie playback ≥2000 frames, manual and automatic playback is supported
8.2 Raw data processing, can be static files and playback of dynamic images for offline
parameter analysis, such as gain, pseudo-color, gray scale curve and other parameters of
adjustment
8.3 Digital hard disk capacity ≥256G, can store dynamic and static images permanently, and
can read, transmit and delete images at any time
8.4 Various exported image formats: Dynamic image and static image are exported directly inPC format, and images can be viewed directly on ordinary PC without special software. At the
same time, the image data can be exported and backed up for real-time inspection without
affecting the inspection operation
8.5 With professional probe placement rack ≥2 (excluding gel placement rack) each probe
placement rack can be changed around

Trolley (Option)

Full Digital Laptop Ultrasound System Caidiac Ultrasound Scanner
 
Probes Optional:
 
1. Convex Array probe
2. High Frequency Linear probe
3. Micro-convex Array probe
4. Trans-rectal probe
5. Transvagional probe
6. 4D probe
7. Visual abortion probe:
Full Digital Laptop Ultrasound System Caidiac Ultrasound Scanner

Clinical Images

 

Full Digital Laptop Ultrasound System Caidiac Ultrasound Scanner
Full Digital Laptop Ultrasound System Caidiac Ultrasound Scanner
 
Full Digital Laptop Ultrasound System Caidiac Ultrasound Scanner
Full Digital Laptop Ultrasound System Caidiac Ultrasound Scanner

 
 

Detailed Photos

Full Digital Laptop Ultrasound System Caidiac Ultrasound Scanner

Full Digital Laptop Ultrasound System Caidiac Ultrasound Scanner

 

Company Profile

Full Digital Laptop Ultrasound System Caidiac Ultrasound ScannerFull Digital Laptop Ultrasound System Caidiac Ultrasound ScannerFull Digital Laptop Ultrasound System Caidiac Ultrasound ScannerFull Digital Laptop Ultrasound System Caidiac Ultrasound Scanner
 

FAQ

 

Full Digital Laptop Ultrasound System Caidiac Ultrasound Scanner
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now