• Hospital Mobile Dr Radiography X Ray System X Ray Machine
  • Hospital Mobile Dr Radiography X Ray System X Ray Machine
  • Hospital Mobile Dr Radiography X Ray System X Ray Machine
  • Hospital Mobile Dr Radiography X Ray System X Ray Machine
  • Hospital Mobile Dr Radiography X Ray System X Ray Machine
  • Hospital Mobile Dr Radiography X Ray System X Ray Machine

Hospital Mobile Dr Radiography X Ray System X Ray Machine

Product Name: Dr Mobile X Ray Machine
Generator Output: 5.0 Kw
Kv Range: 40 Kv - 120 Kv in 1kv Steps
Ma Range: 25~100 Ma
Exposure Time: 4 Films Per Min
X-ray Tube: 1.5*1.5 mm
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Clinical Image
  • Detailed Photos
  • Hot sale
  • Company Profile
Overview

Basic Info.

Model NO.
YJ-5100D
Power Supply
50 Hz
Spatial Resolution
3.7lp/mm
Pixel Size
150μm
Output Gray Scale
14bit
Transport Package
All Our Products Are Packed in Wooden Cases.
Specification
Packing Size(W*D*H)mm: 1330*960*2080
Trademark
FOREVER
Origin
China
HS Code
8419200000
Production Capacity
500 Pieces/Month

Product Description

DR Mobile X Ray Machine YJ-X5100D

Hospital Mobile Dr Radiography X Ray System X Ray Machine

Product Description

 

YJ-X5100D is a high frequency mobile flat-panel digital X-ray radiography system, suitable for radiology department, orthopedics, ward, emergency room, operating room, ICU and other departments. With flexible movement, easy operation, high efficiency, to meet the radiography for all of human body's parts, such as head, limbs, chest, spine, lumbar vertebrae, abdomen, etc.

Hospital Mobile Dr Radiography X Ray System X Ray Machine
1. Monoblock

★ High frequency and High voltage monoblock, 15 years experiences, make sure the stability quality.
★ 50kHz inverter frequency, good x-ray quality, low dose, world top-level technology.
★Thermal capacity 500KJ, long time continuous exposing.
★ With digital closed loop control technology and fault alarm function
2. Exposure Controller
★ Hand controller -- wired exposure
★ Microwave controller -- wireless remote, within 10 meters
 
3. Flat Panel Detector

★ Whole-plate non-spliced, cesium iodide + amorphous silicon flat-panel detectors
derive from the world's leading technology, which greatly improves performance.
★ Version Scope: 14"x 17"
★ Spatial resolution: 3.7Lp/mm
★ Pixel size: 150μm
★ Output gray scale: 16bit

4. Self Balance Function

★ The support arm can stop at any position,
that's our self balance technology, easy
operation.
Hospital Mobile Dr Radiography X Ray System X Ray Machine
 
Hospital Mobile Dr Radiography X Ray System X Ray Machine

5. Networked device: high quality image and output information system
★ The networking functions of PLX5100 include: Dicom storage, Dicom film printing,
Dicom film transfer.
★ It has standard DICOM 3.0 interface, supporting film printing, output, storage,
barrier-free docking hospital PACS system.
6. Workstaion:

Workstation model:IC12A
CPU model: ≥i3
Memory capacity:≥4GB
Hard drive capacity:≥500GB

Product Parameters

Properties
Medical X-ray Equipments & Accessories
Generator output
5.0 kW
kV range
40 kV - 120 kV in 1kv steps
mA range
25~100 mA
Exposure time
4 films per min
X-ray tube
1.5*1.5 mm
power supply
50 Hz
Spatial resolution
3.7Lp/mm
Pixel size
150μm
Output gray scale
14bit

1. Generator output: 5.0 kW
2. kV range: 40 kV - 120 kV in 1kv steps
3. mA range: 25~103 mA mAs: 1.0-180mAs
4. Exposure time: 4 films per min, less than 20 ms per film
5. X-ray tube: Stationary anode tube with a focal spot of 1.5*1.5 mm
6. Collimator: Bright field light beam collimator with 120 W halogen lamp and auto shut-off facility.
7. Power requirements: Single phase 220 V +/- 10% Voltage tolerance; 50 Hz power supply
8. Mobile stand: Light-weight, low height mobile and easily maneuverable stand.
9. The mobile radiographic unit also include a handheld control and a microwave wireless remote control for the 20-meter microwave remote Without the restriction of Barriers and directional, different from the infrared remote control . Grids reduce the fog line filters and raise the degree of scattering contrast.
10. The unit is provided with a line (power) cord of acceptable durability, quality, length and is secured with adequate strain reliefs
The unit include, power plugs that are sufficient for the maximum voltage and current of the unit.
11. The maximum distance from the ground: ≥2000mm, and minimum distance from the ground: ≤500mm. Rotating around the horizontal axis 180 °, rotation around the vertical: ± 90 °, the collimator can rotate 180 °, column can rotate ± 90 °.

Clinical Image

 

Hospital Mobile Dr Radiography X Ray System X Ray Machine

Detailed Photos

 

Hospital Mobile Dr Radiography X Ray System X Ray Machine
Hospital Mobile Dr Radiography X Ray System X Ray Machine
 
Hospital Mobile Dr Radiography X Ray System X Ray Machine
Hospital Mobile Dr Radiography X Ray System X Ray Machine
Hospital Mobile Dr Radiography X Ray System X Ray Machine
Hospital Mobile Dr Radiography X Ray System X Ray Machine

Hospital Mobile Dr Radiography X Ray System X Ray Machine
Hospital Mobile Dr Radiography X Ray System X Ray Machine

Hot sale

 

 

Hospital Mobile Dr Radiography X Ray System X Ray Machine
Hospital Mobile Dr Radiography X Ray System X Ray Machine
 

Company Profile

 

Hospital Mobile Dr Radiography X Ray System X Ray MachineHospital Mobile Dr Radiography X Ray System X Ray MachineHospital Mobile Dr Radiography X Ray System X Ray MachineHospital Mobile Dr Radiography X Ray System X Ray MachineHospital Mobile Dr Radiography X Ray System X Ray MachineHospital Mobile Dr Radiography X Ray System X Ray Machine

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.