Multi-Parameter Patient Monitor CE Aooroved High End Hospital Machine

Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Patient Monitor
Certification: CE, ISO13485
Group: Adult; Pediatric; Neonate
Product Name: Multi-Parameter Patient Monitor
Model: Yj-F5c
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
YJ-F5C
Display
12.1-Inch LED
Printer
Built-in Thermal Printer
Alarm
Three-Level Acousto-Optic Alarm
Power Supply
AC100-240V, 50/60Hz, Power≤60W
Battery
Rechargeable Lithium Battery 14.8V/2200mAh
Dimension
298mm*272mm*122mm
Weight
2.5 Kg (Excluding Accessories)
Input Device
Standard: Knob /Keypress; Option: Touch Screen
ECG
3/5 Lead ECG
Transport Package
Standard Package
Specification
6.5KGS
Trademark
Forermed
Origin
China
Production Capacity
66666 Pieces Per Month

Product Description

YJ-F5C Multi-parameter Patient Monitor (12.1 inches)
Multi-Parameter Patient Monitor CE Aooroved High End Hospital Machine

Multi-Parameter Patient Monitor CE Aooroved High End Hospital MachineFeatures
Multi-Parameter Patient Monitor CE Aooroved High End Hospital Machine
Core
•Classic ARM9 main board based on embedded Linux
•Support storage of 720 hours trend table and graphreview, 2 hours waveform review, 1000 groups NIBPreview and 200 alarm events review

Body
12.1inch high resolution LCD
•Support display max. 11 waveforms
•Support 7 channel ECG waveform display simultaneously

Printer
•Built-in high-speed 50mm thermal printer

Central System
•Wired or wireless connection
•Bed view

Alarm
•Three-level acousto-optic alarm
Human voice alarm
•Sensor-off alarm
•Paper out alarm
•Support alarm review
•Support alarm pause

Linux OS
•Support data export for EMR connectivity by USB
Multi-display mode
NIBP self-test mode
•Support Data Export by USB
•13 types of Arrhythmia analysis and real-time S-T segment analysis and       pacemaker detection
Drug calculation and titration table
•Hemodynamic calculation
Multi-language display

Model Configuration
Standard Configuration 12.1-inch LED, 3/5 Lead ECG, NIBP, SpO2, Pulse Rate, Temperature, Respiration
Optional Configuration 2-Temperature, 1/2 IBP, EtCO2, Masimo SpO2, Nellcor SpO2, Bed View
Optional Accessories Touch Screen, Printer, Central Monitoring Station, Neo/Ped Accessories, Wall-mounting, Trolley

Performance Specifications
Dimension and Weight
- Dimension: 298mm*272mm*122mm
- Weight: 2.5 kg (excluding accessories)
Power Supply
- Voltage: AC100~240V, 50/60HZ, Power≤60W
Display
- 12.1" color TFT LED resolution: 800*600 pixels
Battery
- Type: Rechargeable lithium battery 14.8V/2200mAh
- Charge Cycle: ≥500 times
- Working time: 3.5 hours
Recorder (Option)
- Method: Thermal printer
- Paper width: 50 mm (1.97 in)
- Printing speed: 12.5/25/ 50 mm/s
- Trace: Max. 3 tracks
- Recording way: Real-time Recording, Review Printing,
Periodic Recording, Alarm Recording
Alarm
- Level: Low, medium and high
- Indication: Auditory and visual
- Alarm volume adjustable
- Alarm pause time: 2min
- Parameter alarm type: Latch/ Unlatch
Input Device
- Standard: Knob /Keypress
- Option: Touch screen
System Output & Extensible Interface
- Ethernet Network: standard RJ45 socket * 1pc
- USB Port: 1pc
Operating Environment
- Temperature: 5 ~ 40 ºC
- Humidity: 15% ~ 90% (non-condensing)
- Atmosphere pressure: 86 KPa ~ 110 KPa
Transportation and Storage
- Temperature: -20~50 ºC
- Humidity: 10%~90% (non-condensing)
- Atmosphere pressure: 86 KPa ~ 110 KPa
Safety
- IEC60601-1 Approved, CE marking according to MDD93/42/EEC
- With reference to RoHS Directive 2011/65/EU recasting
Trend & Reviewing
- Trend: 720 hours
- ARR events: 128 groups of ARR events and associated waveform
- NIBP measurement reviewing: 1000 groups
- Waveform review: 2 hours
- Alarm event: 200 alarms events review
SpO2
- Measurement Range: 0 ~ 100 %
- Resolution: 1 %
- Accuracy: ±2% (70% ~ 100%)
Unspecified (0% ~ 69%)
- Support Pitch tone and multi-level volume
- User-selectable waveform speed: 12.5, 25 mm/s
- PI range (Option):0.075%-20%
Pulse Rate
- Measuring and Alarm Range: 20~250bpm
- Accuracy: ±3 bpm
- Resolution: 1bpm
Respiration
- Method: Impedance between RA-LL, RA-LA
- Gain: ×0.25, ×0.50, ×1, ×2, ×4
- Respiration Rate: Adult 0 ~ 120 BrPM
Neonatal / Pediatric 0 ~ 150 BrPM
- Sweep speed: 6.25 mm/s, 12.5 mm/s, 25mm/s
- Resolution: 1 BrPM
- Accuracy:
±2BrPM or ±2% whichever is greater (7~150BrPM)
Unspecified (0%~ 6BrPM)
- Apnea Alarm: 10 ~ 40 s
Temperature
- Technique: Thermistor probe (2.25K)
- Channel: Dual-channel, provide T1; T2; ΔT
- Measuring and Alarm Range: 0.0 ºC~ 50 ºC (32ºF~ 122ºF)
- Unit: Celsius (ºC), Fahrenheit ( ºF)
- Resolution: 0.1ºCor 1ºF
- Accuracy:
no sensor ± 0.1ºC(25ºC - 45ºC) ,± 0.2ºC(other)
include sensor ± 0.2ºC(32ºC - 42ºC)± 0.3ºC(other)
ECG
- Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V
- Protection: Breakdown Voltage 4000VAC 50/60Hz; Defibrillator proof
- Gain: 2.5mm/mV(×0.25), 5.0mm/mV(×0.5), 10mm/mV (×1), 20mm/mV (×2)
- Sweep speed: 12.5mm/s, 25mm/s, 50mm/s
- ECG signal range: ±5 mV p-p
- Accuracy: ±1%
- Resolution: 1 bpm
- Leakage Current < 10 μA
- Baseline Recovery:
≤ 3s after defibrillation
- Bandwidth: Surgery 1 ~ 20Hz
Monitor 0.5 ~ 40 Hz
Diagnostic 0.05 ~ 130 Hz
- Indication of Electrode Separation: Every electrode (exclusive of RL)
Heart Rate
- Measure range: Adult: 15 ~ 300 bpm
Neo/Ped: 15 ~ 350 bpm
- Resolution: 1 bpm
- Accuracy: ± 1%
ST Measurement
- Range: -2.0 ~ +2.0 mV
- Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, whichever is greater, other range: unspecified
NIBP
- Method: Oscillometric
- Measure mode: Manual, Auto, STAT
- Measure Interval in AUTO Mode
1,2,3,4,5,10,15,30,60,90,120,180,240,480 min
- STAT mode cycle time: 5 minutes
- Measure and Alarm Range:
Adult: SYS: 40 ~ 280 mmHg
DIA: 10 ~ 220 mmHg
MEAN: 20 ~ 240 mmHg
Pediatric: SYS: 40 ~ 220 mmHg
DIA: 10 ~ 160 mmHg
MEAN: 20 ~ 170 mmHg
Neonate: SYS: 30 ~ 135 mmHg
DIA: 10 ~ 110 mmHg
MEAN: 20 ~ 110 mmHg
- Static pressure accuracy: ±3mmHg
- Resolution: 1mmHg
- Accuracy: Maximum Mean error ±5mmHg
Maximum Standard deviation ≤8mmHg
- Over pressure Protection: Dual protection
EtCO2 (Mainstream/ Sidestream) (Option)
- Measure method: Non-dispersive infrared (NDIR)
- Measure Range: 0 ~19.7% (0 ~ 150 mmHg)
0 ~ 20 kPa
- Resolution: 0.1 mmHg
- CO2 Accuracy:
0 ~ 40 mmHg, ±2 mmHg
41 ~ 70 mmHg, ±5% of reading
71 ~ 100 mmHg, ±8% of reading
101~ 150 mmHg, ±10% of reading
at 760 mmHg, ambient temperature of 25ºC)
- Respiratory Rate: Range: 3 ~150 BrPM
Accuracy: ±1 bpm
EtCO2 (Micro-stream) (Option)
- Measure method: Non-dispersive infrared (NDIR)
- Measure Range: 0 ~19.7% (0 ~150 mmHg)
0 ~ 20 kPa
- Sample Rate: 50 mL/min ±10mL/min
- Resolution: 0.1 mmHg (0 ~ 50 mmHg)
0.25 mmHg (50 ~ 114 mmHg)
- CO2 Accuracy: 0 ~ 40 mmHg, ±2 mmHg
41 ~ 70 mmHg, ±5% of reading
71 ~ 100 mmHg, ±8% of reading
101~ 150 mmHg, ±10% of reading
at 760 mmHg, ambient temperature of 35ºC)
- Respiratory Rate: Range: 3 ~120 BrPM
Accuracy: ±1 bpm
IBP (Option)
- Max Channel: 2
- Measurement way: Thermal resistance way
- Press Sensor: Sensitivity 5 uV/V/mmHg, ±2%
Impedance 300 to 3000Ω
- Resolution: 1 mmHg
- Unit: mmKg, kPa, cmH2O
- Transducer sites:
Arterial Pressure (ART)
Pulmonary Arterial (PA)
Left Arterial (LAP)
Right Arterial (RAP)
Central Venous Pressure (CVP)
Intracranial Pressure (ICP)
P1/ P2
- Measuring and alarm range:
ART 0 ~ +350mmHg
PA -10 ~ +120 mmHg
CVP/ RAP/ LAP/ ICP -10 ~ +40 mmHg
P1/ P2 -50 ~ +350mmHg
- Accuracy:
Static: ±1mmHg or ±2%, whichever is greater (exclusive of transducer)
±4mmHg or ±4%, whichever is greater (inclusive of transducer)
Dynamic: ±4mmHg or ±4%, whichever is greater

* Specifications subject to change without prior notice

Certificate
Multi-Parameter Patient Monitor CE Aooroved High End Hospital Machine
Packing & Delivery
Multi-Parameter Patient Monitor CE Aooroved High End Hospital MachineMulti-Parameter Patient Monitor CE Aooroved High End Hospital Machine
Our Customer
Multi-Parameter Patient Monitor CE Aooroved High End Hospital MachineMulti-Parameter Patient Monitor CE Aooroved High End Hospital Machine
Company Information
Multi-Parameter Patient Monitor CE Aooroved High End Hospital MachineMulti-Parameter Patient Monitor CE Aooroved High End Hospital Machine
FAQ

Q: Are you a Factory or trading company?
A: We are a factory which is located in Hangzhou,China.Our enterprise(Henan Forever Medical CO.,LTD) has been specialized in medical instruments over 20 years.

Q: What is your quality control process?
A: We are certified with ISO, and strictly follow the ISO procedures. We do 100% testing for medical EQUIPMENT before the order has been deliveried.

Q: Which payment methods do you accept? 
A: We accept most forms of monetary payment such as bank transfer, T/T, direct transfer, L/C and Western Union. Please get in touch with one of our sales managers to check if your payment option is acceptable.



Q: How is the after sales service?
A: We have a professional team which is in charge of after-sales service, also a service hot-line dealing with your complains and feedback.

Q::What is your Delivery Time?
A: 7-15 days after order confirmed.We will make the delivery as soon as possible with the good quality.

Q:How about warranty?
A: We offer one or two years warranty according to different products.
During warranty, if your machine was broken,we will send the broken parts to you freely,and our engineer will teach you how to repair the product.
When you can't repair that by yourself,we will send engineer to your country, or you can send back the machine.





















 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now