• Color LCD Display Biphasic Ambulance Defibrillator Monitor Automated External Defibrillator
  • Color LCD Display Biphasic Ambulance Defibrillator Monitor Automated External Defibrillator
  • Color LCD Display Biphasic Ambulance Defibrillator Monitor Automated External Defibrillator
  • Color LCD Display Biphasic Ambulance Defibrillator Monitor Automated External Defibrillator
  • Color LCD Display Biphasic Ambulance Defibrillator Monitor Automated External Defibrillator
  • Color LCD Display Biphasic Ambulance Defibrillator Monitor Automated External Defibrillator

Color LCD Display Biphasic Ambulance Defibrillator Monitor Automated External Defibrillator

Type: ECG
Certification: CE, ISO13485
Product Name: Aed Automated External Defibrillator
Model: Yj-D9000
Application: First Aid
Certificate: CE
Samples:
US$ 2250/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Trading Company
  • Overview
  • Product Description
  • Company Profile
Overview

Basic Info.

Model NO.
YJ-9000D
Screen Size
7 Inches(17.7 Cm) Diagonally
Waveform
Biphasic
ECG
3/5-Lead ECG Cable
Paper
50mm Thermal
Transport Package
Standard Package
Specification
57x57x26cm
Trademark
FORERMED
Origin
China
HS Code
8419200000
Production Capacity
6666pieces/Year

Product Description

Product Description

 


YJ-9000D Medical Equipment aed defibrillator/aed automated external defibrillator unit

Color LCD Display Biphasic Ambulance Defibrillator Monitor Automated External Defibrillator

   

Physical characteristics for aed automated external defibrillator unit:

Main unit: Portable
Dimensions: L320xW205xH410
Weight: 9.8kg



 
DEFIBRILLATOR
(1) Defibrillator type Manual, Synchronized, Asynchronized
(2) Out put waveform Monophasic technology
(3) Energy accuracy ∠+1%
(4) Energy selection 0,3,5,7,10,20,30,50,100,200,300,360 joule(normal at a resistance of 50)
(5) Charging time Maximum 8 seconds to 360 Joules
(6) Standard Adult/Pediatric Paddles Reusable extermal adult paddles(pediatric paddles integrated).
Power requirements.
(a) AC Power supply 110V, 60 Hz /220V,50 Hz
(b) Vehicle Voltage DC 12V
 

Technical specifications for aed automated external defibrillator unit:

 
Internal Battery Backup
(1) Battery type Rechargeable lead-acid battery/ lithium battery(optional)
(2) Charging time Time-Minimum of 4 hours for full charging
(3) Battery charging During AC Power Supply operation of the device.
(4) Charging /Low Battery Indication Red LED
(5) Battery Capacity 100% of the battery will provide 120 mins of monitoring; and 30 discharges at 3
60 joules.

Display
LED Dimensions 7'diagonal {155mm*88mm}
Type High resolution true-color graphic LED
Resolution 480X234

ECG  
ECG lead: I, ‖,III , AVR, AVL, AVF, V1~V6, GND
S-T segment analysis: -2.0~2.0mv
Arrhythmia analysis: yes
Protegtion: With stand 4000vAc/50Hz voltage in isolation and work against
eletrosurgical interence and defibrillation

NIBP  
Working mode: Manual/Automatic/stat(5 minutes)
Method: Automatic oscillation
Cufftype: standard Adult; optional Pediatric/Neonatal

Temperature  
Measurement range 20~45°C
Resolution 0.1°C
Pulse Oximetry (spO2)
Display : spo2 value,pulse histongram,waveform,Pulse
Range: 0~99%for adult,pediatric and neonatal patients
Probe: standard adult finger clip optional pediatric Y-type clip and neonatal wrap

Standard parameter & configuration:
ECG/ RESP,/SPO2,/TEMP,/PR,/NIBP/DEFIBRILLATOR
Optional parameter
Recorder

Pulse range:Pulse range: 0-255bpm Respiration: Measurement method: Thoracic impedance.
 
 
YJ-9000D is a compact durable light weighted defibrillator which integrated monitoring manual defibrillation.with 6 parameter patient monitor
It is a professional biphasic defibrillator-monitor suitable for hospitals and clinics
Standard Configration : Monophasic Defibrillator, ECG.RESP.SPO2.TEMP.PR.NIBP,Biphasic function optional

 
Screen 7 inches (16.5 cm) diagonal, non-fade.Type: color (TFT)
Display Resolution: 800 x 600 pixels.
Sweep Speed: 12.5mm/s,25mm/s,50mm/s
Defibrillator type: Manual, Synchronized, A synchronized,
Output waveform: Monophonic technology /Biphasic technology (optional)
Energy accuracy: ∠+1%
Energy selection: 0,3,5,7,10,20,30,50,100,200,300,360 joule(nominal at a resistance of 50)
Charging time: Maximum 8 seconds to 360 Joules
Standard Reusable external adult paddles (pediatric paddles integrated)
Power requirements.
AC Power supply :110V, 60 Hz /220V, 50 Hz .DC 12V
Battery type: Rechargeable lead-acid battery/ lithium battery (optional) Charging time: Time-Minimum of 4 hours for full charging
Battery charging: During AC Power Supply operation of the device. Charging /Low Battery Indication: Red LED
Battery Capacity: 120 min of monitoring; and 30 discharges at 360 joules.
Steps for the heart defibrillation(Asynchronous DC defibrillation)

The following treatment steps only applies to the heart defibrillator. This does not apply to the machinery, cardiopulmonary or pharmacological recovery fields. The basic premise of synchronous DC defibrillation is ventricular fibrillation, which means that in the victims' electrocardiogram have P-QRS wave or T wave defects.

 
  1. Turn On the defibrillator
 
  1. Put the conductive gel on the two electrode pads.
Remember enough gel on the pads in order to reduce transmission resistance and more energy into the victims. Too little gel possibly causes the skin burning under the pads.
Note: No gel to the hand of the electrode pads. Otherwise, it is dangerous to transfer the electric spark to the operator or doctor.

 
  1. Energy selection
The discharging energy confirms with the victims' height and weight. It is around 2 joule/kgs. Also it is according to experiences and the specific aid situation.
 
  1. Position of electrode pads
The pads should be firmly pressed on the victims' naked chest. Also for the safe energy transmission, it is necessary to press with around 10kilograms force. Too small force will also cause the skin burning. It is necessary to do practice on the training instrument for the correct position.

The pads position is crucial to the successful recovery. So the current between the electrodes should transfer the chest to myocardial tissue. Only when 80% heart being defibrillating, and get to "critical mass", possibly the fibrillation can be over.

Wrong position of electrode pads will cause large loss of current from the heart side without any effect. Correct position of sternum electrode: -Right Chest
-Right side of sternum
-Beneath the clavicle

Correct position of pole electrode -Beneath the left chest
-Above apex
-Center of axillary line
 
Company Profile

 

Color LCD Display Biphasic Ambulance Defibrillator Monitor Automated External Defibrillator

Color LCD Display Biphasic Ambulance Defibrillator Monitor Automated External DefibrillatorColor LCD Display Biphasic Ambulance Defibrillator Monitor Automated External DefibrillatorColor LCD Display Biphasic Ambulance Defibrillator Monitor Automated External DefibrillatorColor LCD Display Biphasic Ambulance Defibrillator Monitor Automated External DefibrillatorColor LCD Display Biphasic Ambulance Defibrillator Monitor Automated External Defibrillator

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now