• Patient Monitor/Acdiac Monitor with 12.1 LED Screen
  • Patient Monitor/Acdiac Monitor with 12.1 LED Screen
  • Patient Monitor/Acdiac Monitor with 12.1 LED Screen
  • Patient Monitor/Acdiac Monitor with 12.1 LED Screen
  • Patient Monitor/Acdiac Monitor with 12.1 LED Screen
  • Patient Monitor/Acdiac Monitor with 12.1 LED Screen

Patient Monitor/Acdiac Monitor with 12.1 LED Screen

Model: Yj-F6
Display: 12.1 Inch High-Brightness TFT LED
Main Board: A9
Language: Multi-Language Display
Transducer Socket: ECG, SpO2, NIBP, IBP, Temp, Etco2
Print: Seiko, Japan
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Trading Company
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
YJ-F6
ECG
7 Channel
Application
Neonatal Intensive Care etc
Alarm
Yes
Guarantee Period
One Year
Transport Package
Standard Package
Specification
Small size
Trademark
Formed
Origin
China
Production Capacity
4500/Year

Product Description

YJ-F6 medical device First-Aid Beside Cardiac ECG Portable Patient  Monitor
Patient Monitor/Acdiac Monitor with 12.1 LED Screen

Features:
  • 12.1'color TFT LED screen supports display Max.8 waveforms
  • Suitable for monitoring adult, pediatric and neonatal patient
  • Designed without fan, characterized with no noise and lower consumption
  • Acoustic and visual alarm 
  • Analog SpO2 technology, against interference of ESU, motion & low infusion
  • Display mode: Standard, Large Font, Trend Table, Full lead ECG, Oxy CRG 
  • Drug calculation and titration table 
  • Pacemaker detection and Arrhythmia analysis 
  • Supporting large capacity of storage 
  • Isolated against defibrillation effect
 
Standard Configuration:
3-lead or 5-lead ECG/HR, RESP, Dual TEMP, SpO2/PR, NIBP 

Optional Configuration:
2 IBP, Central Monitoring System, Touch screen, Printer, Trolley, Wall-mount
Patient Monitor/Acdiac Monitor with 12.1 LED Screen

Specification:
 
ECG Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V
Gain: 2.5mm/mV(×0.25), 5.0mm/mV(×0.5), 10mm/mV (×1), 20mm/mV (×2), 40 mm/ mV (×4), Auto
Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50 mm/s
ECG signal range:  ±12 mV (Gain × 0.25) Auto
ECG signal range:  ±6 mV
Accuracy: ±1bpm/ ±1%, whichever is greater
Resolution: 1 bpm
RESP Method: Impedance between RA-LL, RA-LA
Gain: ×0.25, ×0.50, ×1, ×2
Respiration Rate: Adult: 0 ~ 120 BrPM;
 Neonatal / Pediatric: 0 ~ 150 BrPM
Resolution: 1 BrPM
Accuracy: ±2 bpm or ±2%, whichever is greater
Apnea Alarm: 10 ~ 40 s
NIBP Method: Oscillometric
Measure mode: Manual, Auto, STAT
STAT mode cycle time: Keep 5 minutes, at 5 seconds interval
Measure and Alarm Range: Adult:SYS:  40 ~ 280 mmHg,DIA:  10 ~ 220 mmHg ,MEAN:  20 ~ 240 mmHg
Static pressure accuracy: ±3mmHg
Resolution: 1mmHg
Accuracy: Maximum Mean error ±5mmHg           

 Maximum Standard deviation ≤8mmHg
Over pressure Protection: Dual protection via software & hardware
SPO2 Measurement Range: 0 ~ 100 %
Resolution: 1 %
Accuracy: 70% ~ 100%: ±2 %  
         40% ~ 69%, ±3 %;
         <39%, unspecified;
TEMP Channel: Dual-Channel, provide T1; T2; ΔT
Measuring and Alarm Range: 0.0 ºC~ 50 ºC (32ºF~ 122ºF)
Resolution: 0.1ºCor 1ºF
Accuracy: ±0.1ºC(exclusive probe error)
PR Measuring and Alarm Range: 20~300bpm
Accuracy: ±3bpm
Resolution: 1bpm