• Hospital Product Laboratory Full Auto Chemistry Analyzer
  • Hospital Product Laboratory Full Auto Chemistry Analyzer
  • Hospital Product Laboratory Full Auto Chemistry Analyzer
  • Hospital Product Laboratory Full Auto Chemistry Analyzer
  • Hospital Product Laboratory Full Auto Chemistry Analyzer
  • Hospital Product Laboratory Full Auto Chemistry Analyzer

Hospital Product Laboratory Full Auto Chemistry Analyzer

Classification: Biological Diagnostics
Type: Biochemistry Analyzer
Certification: CE, ISO13485
Group: Middle-aged and Old
Reaction Volume: 150UL
Reagent Positions: 80 Reagent
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Trading Company
  • Overview
  • Product Description
  • Technical specification
  • Company Profile
Overview

Basic Info.

Model NO.
YJ-220
Sample Plate
120 Sample Positions
Sample Volume
2-100 UL, Step by 0.1 UL
Software
Windowsxp \2000
Dimension
912*721mm*570mm
Warranty
24 Month
Transport Package
Standard Export Package
Specification
300 test/h
Trademark
FORERMED
Origin
China
Production Capacity
600sets/Month

Product Description

Product Description

Auto Biochemistry Analyzer YJ-220

Application 

Our biochemistry analyzers are multi-functional. Many test items can be done by our biochemistry analyzers. Following are test details:  

1. Liver Functions Test: ALT, AST, TP, ALB, TBIL, DBIL, ALP, CHE, TBA, PA, A/G 

2. Renal Functions Test: Urea, Cr, TCO2, UA 

3. Lipids: CHOL, TG, HDL-C, LDL-C, Apo A1, Apo B, AMY, LIP, LP(a) 

4. Myocardial Enzymes: LD, CK, CK-Mb 

5. Ion: K+, Na+, Cl-, Ca++, Mg++, P 

6. Other Items: GLU, Fe, GRP, IgG, IgA, IgM, G3, G4 
Hospital Product Laboratory Full Auto Chemistry Analyzer

Technical specification

Specification of Auto Biochemistry Analyzer YJ-300:

Model

YJ-300

Throughput

Constant 300/h

Theory

Absorption spectrometry, transmission turbidimetry

Methodology

End-point \Fixed-time\Kinetic\Ion selective electrode

Test according set up, random access

Reaction plate

Contain 81 reaction cuvettes

Maximum reaction time

15 minutes

Minimum reaction volume

150 ul

Material of cuvettes

Special UV-transparent optical glass

Cuvettes use

Automatically cuvettes washing

Optical Unit

Light Source

Halogen-tungsten lamp

Photometer

Reversed optics

Wavelength

340nm-900nm wavelength option

Absorption

0-4 Abs

Reagent Unit

Reagent plate

80 reagent positions ,support for single and double reagent, reagent completely open

Reagent storage temperature

2~10 degree

Reagent bottle

15ml, 20ml, 30ml, 50ml or 70ml ,dead volume is less than 1.0 ml

Reagent volume

20-500 ul, step by 1.0 ul

Reagent/Sample Probe

Automatically checked ;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside.

Sample Unit

Sample plate

80 sample positions

Sample type

Human (animal) serum \plasma\urine etc.

Samples cup

Support one-off micro cups

Sample volume

2-100 ul, step by 0.1 ul

Sample/reagent probe

Automatically checked ;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside.

Temperature control Unit

Heating method

Direct thermal solid thermostat closed

Temperature equilibrium time

<3 minutes

Reaction temperature

37 ±0.1 degree

Temperature fluctuation

±0.1 degree

Operation Unit

Software

WindowsXP \2000

Database

SQL Server

Data Storage

Automatic store & copy; No time and volume limit; Lifetime preservation

Print format

Can be set up, offer several standard format

Calibration mode

Linear curve type: Single-point linear, two-point linear and multi-point linear none linear; Curve type: Logistic-Log 4P,Logistic-Log5p,Spline,index automatically use best calibration curve and standard

Quality control methods :

Real time, within day & between day

Quality control diagram

L-J \cumulative\twin plot

Status display

Real time monitoring of reagent residual volume .Running status of reagent tray, samples tray

Adjustment

Dynamic and real time display of running status; Intelligent carry over settings to adjust test sequence; original reaction data record; Detail profile of alert messages

Setting

Operation permission setting, Item setting, cross pollution setting, cuvette blank setting

Others

Water consumption : < 6L/h

Power Supply :AC 220V±22V 50Hz±1Hz

Frequency :Maximum 600VA

Dimension :782mm×581mm×545mm

Net Weight : 60kg

Accessory :Software


Relative equipment:
Hospital Product Laboratory Full Auto Chemistry Analyzer
Hospital Product Laboratory Full Auto Chemistry Analyzer
Hospital Product Laboratory Full Auto Chemistry Analyzer

Company Profile

Hospital Product Laboratory Full Auto Chemistry AnalyzerHospital Product Laboratory Full Auto Chemistry Analyzer


FAQ:
1).What's your product lead time?

3 working days around if we have the products in stock, if not in stock, 5-7 working days around to finish the production.
2). What's the warranty for the products ?
A: The free warranty is 24 month from the date of commissioning qualified.

3).How to maintenance the product if it has problem?
We have professional engineers,they will solve your problem by communicating with skype or phone, or make video for you. If the machine is totally broken and can not work, send it back to us and we will send a new one to you. 
4).What's your shipping terms?
Foermed offers courier,air,sea shipping methods.Client can choose anyone depends on detail situation. 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now