• Clinical Human Veterinary Dry Biochemical Analyzer Fully Automatic Dry Chemistry Analyzer
  • Clinical Human Veterinary Dry Biochemical Analyzer Fully Automatic Dry Chemistry Analyzer
  • Clinical Human Veterinary Dry Biochemical Analyzer Fully Automatic Dry Chemistry Analyzer
  • Clinical Human Veterinary Dry Biochemical Analyzer Fully Automatic Dry Chemistry Analyzer
  • Clinical Human Veterinary Dry Biochemical Analyzer Fully Automatic Dry Chemistry Analyzer
  • Clinical Human Veterinary Dry Biochemical Analyzer Fully Automatic Dry Chemistry Analyzer

Clinical Human Veterinary Dry Biochemical Analyzer Fully Automatic Dry Chemistry Analyzer

Classification: Biochemical Apparatus
Type: Biochemistry Analyzer
Certification: CE, FDA, ISO13485
Group: All
Product Name: Auto Chemistry Analyzer
Display: 4.3 Inch Touch Screen
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Reagent
  • Operation Guidance
  • Detailed Photos
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
YJ-BA320
Test Mode
Absorbance
Quick Results
13 Minutes
Reagent Disc
Disposable, Prepackaged with Self-Contained Lyophi
Reaction Temperature
37ºC±0.1ºC
Data Capacity
More Than 50,000 Sets of Patient and Quality Contr
Operation Environment
Temperature 10-30ºC, Humidity 40-85%
Transport Package
Carton
Specification
53*47*27
Trademark
FORERMED
Origin
China
Production Capacity
300pieces/Month

Product Description

Product name
 

Product Description

Clinical Human Veterinary Dry Biochemical Analyzer Fully Automatic Dry Chemistry Analyzer
The YJ-BA760 chemistry analyzer provides quantitative in-vitro determinations of clinical chemistry analytes in lithium-heparinized whole blood, heparinized plasma, or serum. The entire analysis requires about 100 μL of sample and is capable of providing results in about 13 minutes.

Clinical Human Veterinary Dry Biochemical Analyzer Fully Automatic Dry Chemistry Analyzer
EASY TO USE

* Fully automated system - no special operating skills recuired
* 4.3 inch capacitive touch screen
* 0.1oc whole blcod. serum or plasma
* Barcoded prefabricated calibration information
* LIS compatible. no need to manually enter patient information
* Results could be printed through a thermal printer (optional) , an office printer cr throughdata management platform (MMDMP)
* Ability to print reports with your practice logo by installing the MNCHIP medical datamanagement platform
PRECISE MEASUREMENTSA
dvanced technology ensures precise results


Microfiuldic discs with preinstalled reagent beads ensure accurate analysis of blood samples and reagents


Stable measurement optics include a troboscopic xenon lamp, a wavelength selection system, and a muliple-wavelength detector


Integrated qually control soware montors the entre process in real time (ensurn consistent analvsis of bkod sampies. reagents. microtuidc discsand chemistry analyzer)
Clinical Human Veterinary Dry Biochemical Analyzer Fully Automatic Dry Chemistry Analyzer

 

Product Parameters

Sample Type
Whole blood(lithium-heparinized), Plasma(lithium-heparinized), Serum
Sample Size
100μl
Time to Results
About 10 minutes
Parameters
Up to 17 parameters in one test, 32 parameters configured into 9 profiles
Reagent Disc
Disposable, prepackaged with self-contained lyophilized reagent
Calibration
Automatic self-calibration by scanning QR Code on the aluminum foil pouch
Quality Control
Built-in Realtime Quality Control(RQC) system
User Interface
Full-color touch screen
Connection Interfaces
WLAN, USB port, Ethernet interface, compatible with HIS
Print Mode
Optional external thermal printer, MNCHIP Medical Data Management Platform, HIS
Reaction Temperature
37ºC±0.1ºC
Data Capacity
More than 50,000 sets of patient and quality control data
Operation Environment
Temperature 10-30ºC, Humidity 40-85%
Power Requirement
AC 100V-240V, 50-60HZ
Dimensions
21(L)*12.5(W)*17.5(H)cm
Weight
2.3kg
Analyzer dimensions: 210mm(L)×125mm(W)×175mm(H)
Weight: Ca. 3kg
Mode of operation: Continuous
Ambient operating temperature: 10~30ºC(50-86 ºF), indoor use
Atmospheric pressure: 86.0 kPa~106.0 kPa/2000 m (6562 ft)
Humidity: 40%~85%
Power requirements: 82 VA
Main supply voltage: 100-240 volts AC, 50-60 Hz
Reaction Temperature 37ºC(98.6 ºF)

Reagent

Clinical Human Veterinary Dry Biochemical Analyzer Fully Automatic Dry Chemistry Analyzer

 

Clinical Human Veterinary Dry Biochemical Analyzer Fully Automatic Dry Chemistry Analyzer

Operation Guidance

Clinical Human Veterinary Dry Biochemical Analyzer Fully Automatic Dry Chemistry Analyzer

 

Detailed Photos

Clinical Human Veterinary Dry Biochemical Analyzer Fully Automatic Dry Chemistry AnalyzerClinical Human Veterinary Dry Biochemical Analyzer Fully Automatic Dry Chemistry AnalyzerClinical Human Veterinary Dry Biochemical Analyzer Fully Automatic Dry Chemistry Analyzer
Clinical Human Veterinary Dry Biochemical Analyzer Fully Automatic Dry Chemistry Analyzer Clinical Human Veterinary Dry Biochemical Analyzer Fully Automatic Dry Chemistry Analyzer

Company Profile

Clinical Human Veterinary Dry Biochemical Analyzer Fully Automatic Dry Chemistry AnalyzerClinical Human Veterinary Dry Biochemical Analyzer Fully Automatic Dry Chemistry AnalyzerClinical Human Veterinary Dry Biochemical Analyzer Fully Automatic Dry Chemistry AnalyzerClinical Human Veterinary Dry Biochemical Analyzer Fully Automatic Dry Chemistry Analyzer

FAQ

Clinical Human Veterinary Dry Biochemical Analyzer Fully Automatic Dry Chemistry Analyzer

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now