Type: Hematology Analyzer
Certification: CE, ISO13485
Name: Infant Radiant Warmer
Model: Yj-Biw100
Phototherapy Unit: LED Phototherapy Unit
Transport Package: Standard Package
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Trading Company
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
YJ-BIW100
Trademark
forermed
Origin
China
HS Code
9018193010
Production Capacity
5000pieces. Month

Product Description

Product Description

INFANT RADIANT WARMER

• Microprocessor based servo controlled temperature system
• Three modes: pre-warm, manual or automatic
• Set temperature and skin temperature failure,over temperature.
• APGAR timer to record therapy time
• Convenient X-ray cassette tray under infant mattress
• Heater head can be adjusted ±90° horizontally
• Inclination of infant bed is ajustable
• LED observe light angle is adjustable
• Transparent protector can be folded down, with two infusion seals
• RS232 connector
• Optional parts; bigger infant bed, low pressure aspirator, LED phototherapy unit,
  internal/external infant resuscitor (T pieces), air and oxygen blender, gel mattress, oxygen supply system,
  electric height adjustable, air temperature & count down timer, infant head fixing unit, infant oxygen hood

  • Temperature control range
    25°C -37°C
    Temperature override mode to
    38°C
    Temperature sensor accuracy
    ≤0.3°C
    Mattress surface temperature uniformity
    ≤2.0°C
    Temperature rise time
    ≤45mins
    Heat output indicate
    0-100% in 10%
    Radiant box horizon angle adjust range
    0-90°adjustable in step-less
    Bed tilt adjustment
    continues adjustable in ±10°
    Mattress tray size
    1700px*1350px
    Mattress tray Max. load
    10kg
    Transfusion pole Max. load
    2kg
    Shelf Max. load
    2kg

X-ray Cassette Oxygen Supply System Infant Radiant Warmer


X-ray Cassette Oxygen Supply System Infant Radiant Warmer
YJ-BIW100 Infant Radiant Warmer

Brief introduction: 

1. Microprocessor based servo controlled temperature system.
2.The microprocessor-controlled unit allows for three settings: pre-warm, manual or automatic.
3.Alarm functions for safety includes:
Power failure;
Temperature deviation;
Temperature sensor failure;

Over temperature.
1. APGAR timer to record therapy time
2. Convenient X-ray cassette under infant bed 
3. Heater head can be adjusted +90º horizontally
4. Tilt angle of infant bed is adjustable
5. Observe light angle is adjustable
6. Transparent protector folded
7. Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source,the heating is quick and life-span is long
8. Alarms are audible and visual 
9. A second thermal cut-out function for more safety
10. Skin temperature sensor failure protect function avoid over temperature
11.  Temperature deviation can be amended in front panel directly


Standard configuration:
Main body (including the radiant source, control system, infant bed, bracket), X-ray cassette , Observe light , I.V.pole, skin temperature sensor, tray, mattress, transparent protector, castors. 
Optional parts: 
Drawer;
RS-232(485) connector;


Technical data:
1.Power supply : 110/220V 60/50Hz 
2.Power input: ≤1200VA
3.Operating condition:
An ambient Temperature:18°C -30°C
An ambient Relative Humidity: 30%--75%RH
Atmospheric Pressure: 700~1060 hPa
An ambient Air Velocity < 0.3 m/s
4. Temperature control: 32°C~38°C
5.Temperature control accuracy: ≤0.5°C
6.Mattress temperature uniformity : < 2°C
7.Skin temperature sensor accuracy: + 0.3°C
8.Warm-up time: ≤30min
9. Infant bed tilt angle:+ 10°
10.APGAR timer range: ≤24h
11.Heater head horizontal: ±90°
12.Mattress size: 67cm × 54cm
13.Distance from heater to mattress:80cm
Transport and storage:
Environment Temperature:-40°C ~ +55°C
Environment Relative Humidity: ≤95%
Atmospheric Pressure: 500~ 1060hPa


Package:
Each unit is packed one case 
Size:120cm× 70cm × 96cm
Gross weight: ≤90kg


Details and parameters:
Technical specification:
1. Air temperature Air temperature display range: 0°C-60°C; Air temperature control range: 20.0°C-37.0°C 37.1°C-39.0°C; Air temperature accuracy: +0.3°C; Air temperature deviation alarm: ±3.0°C.
2. Skin temperature Skin temperature display range: 0°C-60°C; Skin temperature control range: 20.0°C-37.0°C 37.1°C-38.0°C; Skin temperature accuracy :±0.3°C; Skin temperature deviation alarm: ±1.0°C.
3. Humidity Humidity display range: 0%--99%RH; Humidity control range: 30%-95%; Humidity control accuracy:(10% - 90% at 20 - 40C)±5%RH.
 
4. Oxygen concentration (Optional) Oxygen concentration setting range: 21%-65% Oxygen concentration display range: 18%-99% Oxygen concentration display accuracy: 2% Oxygen concentration control accuracy: 3%
5. Baby weight scale(Optional) Weight range: 500g-10kg Weight accuracy: ±10g Display trend diagram of baby weight
6. Pulse Oximeter monitor (Optional) SpO2: measure range 0-100%, display resolution 1%; Pulse rate (PR): measure range 25-250bpm,display resolution 1bpm; Perfusion index(PI): measure range 0-20%,display resolution 0.001%; Variability index: measure range 0-100%,display resolution 1%.
 
7. ECG (Optional) ECG measure range: 0.15mV-5.5mV ECG measure accuracy: 2.36uV/LSB Breath measure range: 15-120rpm Heart rate measure range: 15-300bpm Heart rate measure accuracy: ±1bpm Body temperature measure range: 0-50°C Body temperature measure accuracy: 0.1°C
X-ray Cassette Oxygen Supply System Infant Radiant WarmerX-ray Cassette Oxygen Supply System Infant Radiant Warmer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now