Type: Anaesthesia Machine
Certification: CE, ISO13485
Group: Adult and Pediatric
LCD Display: With LCD Display
Transport Package: Standard Package
Specification: 830*770*1230
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Trading Company
  • Overview
  • Product Description
  • Company Profile
Overview

Basic Info.

Model NO.
YJ-820
Trademark
Forever Medical
Origin
China

Product Description

Product Description

 


YJ-820 Multi-functional Anesthesia machine
 
Anesthesia Machine Anesthic Workstation with Build in Ventilator Anesthesia Machine


Features:

Pneumatically driven and electrically controlled system
Built-in ventilator, 5.7"LCD display screen
Closed; Semi-Closed; Semi-Open working mode
Applied for Adult and Pediatric

 
Main technical specifications:
Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from O2 & NO2: 0.32~0.6 MPa.
4-tubes Flowmeters: O2 & N2O; 0.1L/Min ~ 10L / Min;
Oxygen Flush: 25~75 L / Min
Respiration Mode: A/C, IPPV, VCV, SIPPV, IMV, SIMV, MANNUAL
Tidal Volume Adjustable range: 50 ~ 1500 ml, Display range:0~2000ml
I/E Ratio: 8:1~1:10
One vaporizer Enflurane/ Isoflurane/Sevoflurane/Halothane
Vaporizer Setting Range 0.5%~5% Respiration Frequency: 1~100 bpm;
Lung compliance ≤30 mL / kPa IMV frequency: 1~20 bpm
PEEP 0~2.0KPa
Ptr: -1.0~2.0KPa
CO2 absorber capacity   1 kg Inspiratory Plateau: 0~1 S
Optional Patient monitor
Alarm parameters upper/lower limit of airway pressure, tital volume exceed
limitation, no tidal volume output, apnea, AC power malfunction, Battery low power

Customer feedback
Anesthesia Machine Anesthic Workstation with Build in Ventilator Anesthesia Machine
 
Company Profile

 


Our company
Anesthesia Machine Anesthic Workstation with Build in Ventilator Anesthesia MachineAnesthesia Machine Anesthic Workstation with Build in Ventilator Anesthesia MachineAnesthesia Machine Anesthic Workstation with Build in Ventilator Anesthesia MachineAnesthesia Machine Anesthic Workstation with Build in Ventilator Anesthesia MachineAnesthesia Machine Anesthic Workstation with Build in Ventilator Anesthesia Machine


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now