Customization: | Available |
---|---|
Type: | Monitor |
Product Name: | Vet Monitor |
Still deciding? Get samples of US$ 299/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Handheld Portable Multi-Parameters Patient Monitor Patient Monitor Veterinary Animal Vet Multi Parameter Patient Monitor
Vital Sign Monitor
WIFI with smart IT solutions
- Wireless integration with Central Monitoring Statione
TECHNICAL SPECIFICATIONS
|
|
Application Range
|
Aduit/Pediatric/Neonatal/Medicine/Surgery
|
Display
|
8" real color TFT screenResolution:800*600
One alarm indicator One working indicator One battery charge state indicator |
Date Storage
|
Trend diagram/table: 720h NIBP review: 1000group
Wave review: 12h Alarm revie: 200 alarm events |
Environment
|
Operating environment: Temperature:0-40C
Humidity:15%-80% Pressure:86.0 kPa-106.0kPa Transport and Storage environment Temperature:-20-55C 10%~90% Pressure:86.0 kPa-106.0kPa |
Power Requirements
|
Power RequirementsAC:100~240V,50HZ/60HZ
DC: Built-in rechargeable batteryBattery: 11.1V 24wh Li-ion battery 2h operating after full charge 5min operating after low battery alarm |
Dimension and Weight
|
164.2mmx270.2mm x128.7 mm(about) 2.5kg(about)
Package 360*250*290mm 4kg(about) |
Sp02
|
Measurement range:0-100% Resolution Accuracy:70%~100%±2% 40%~69% ±3%
|
Pulse Rate
|
Measure/alarm range:20-300bpmResolution:1bpm
Accuracy:+3bpm |
NIBP
|
Method Oscillometry Measure mode: Manual Auto, STAT
Measure interval in auto mode 1-5/10115/3060/90/120/180/2401480m Measure period in STAT mode: 5min Pulse rate range:40-240bpm Measure &alarm range: Aduit SYS 40-280mmHg DIA 10~220mmHg MEAN 20-240mmHg Pediatric SYS 40~220mmHg DIA 10-160mmHg MEAN 20-170mmHg Neonatal SYS 40~135mmHg DIA 10-100mmHg MEAN 20-110mmHg Static pressure measurement Range:0-300 mmHg Accuracy:+3 mmHg Resolution:1 mmHg Accuracy Max Mean Error:± 5mmHg Max Standard Deviation:8mmHg Overpressure protection Adult 300mmHg Pediatric 240mmHg Neonatal 150mmHg |
Standard accessories
|
- NIBP cuff&tube - SpO2 sensor
- Lithium-ion battery - Power cable - Operators manual |
Optional accessories
|
spo2 Suntech NIBP
|