Customization: | Available |
---|---|
Classification: | Physiological Functions of Diagnosis and Monitoring Equipment |
Type: | Patient Monitor |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Body 8.0 inch high-brightness TFT LED Support display maximum 8 waveforms Support 6 channel ECG waveform display simultaneously Optional touch screen |
Central System Optional: supporting wired or wireless connection to the central monitoring station. |
Stroage Support storage of 168 hours trend table and graph review 100 minutes waveform review 500 groups NIBP review 100 hours of parameter alarm events review and associated parameters |
Alarm Three-level acousto-optic alarm Sensor-off alarm Paper out alarm Support alarm review Support alarm pause |
Printer Built-in high-speed 50 mm thermal printer (Brand: SEIKO, Japan) |
Operating System Multi-display mode to meet different clinical requirement, including standard interface, big font, OxyCRG, trend graph, NIBP review and full leads ECG interface. NIBP self-test mode: including overpressure test, static pressure test and air leakage test. 15 types of Arrhythmia analysis and real-time S-T segment analysis and pacemaker detection Drug calculation and titration table Support multi-language display Support online software upgrading by net |
Interface Transducer socket ECG SPO2 NIBP TEMP 1 TEMP 2 / Mainstream EtCO2 |
LAN / Central monitor system interface The LAN port is for connecting the monitor to a central monitor system network. Input device interface Knob (Standard) Touch screen (optional) |
Dimension and Weight - Dimension: 175mm*210mm*80mm - Weight:1.35kg(excluding accessories) Power Supply - Adapter: Output 13-20V DC, 5A - Voltage: AC100~240V, 50/60HZ Display - 8" color TFT LED - Resolution: 800*600 pixels Battery (Pluggable) - Type: Rechargeable lithium battery 14.8V/2200mAh - Charge Cycle: ≥500 times - Working time: 5.5 hours Recorder (Option) - Method: Thermal printer - Paper width: 50 mm (1.97 in) - Printing speed: 25/ 50 mm/s - Trace: Max. 2 tracks - Recording way: Real-time Recording, Alarm Recording Alarm - Level: Low, medium and high - Indication: Auditory and visual - Alarm volume adjustable - Alarm pause time: 1min, 2min - Parameter alarm type: Latch/ Unlatch Input Device - Touch screen (option) - Knob (Standard) - Keypad input (Standard) System Output & Extensible Interface - Ethernet Network: 1 standard RJ45 socket Operating Environment - Temperature: 5 ~ 40 ºC - Humidity: 15% ~ 80% (non-condensing) - Atmosphere pressure: 86 KPa ~ 110 KPa ST Measurement - Range: -2.0 ~ +2.0 mV - Accuracy: -0.8mV ~ +0.8mV: ±0.02mV or ±10%, whichever is greater - Other range: unspecified Respiration - Method: Impedance between RA-LL, - Gain: ×0.25, ×0.50, ×1, ×2, - Respiration Rate: 0bpm, 0 ~ 150 BrPM - Sweep speed: 6.25 mm/s, 12.5 mm/s, 25mm/s - Resolution: 1 BrPM - Accuracy: ±2 bpm or ±2%, whichever is greater - Apnea Alarm: 10 ~ 40 s NIBP - Method: Oscillometric - Measure mode: Manual, Auto, STAT - Measure Interval in AUTO Mode 1~480 min - STAT mode cycle time: Keep 5 minutes, at 5 seconds interval - Measure and Alarm Range: Adult SYS: 40 ~ 270 mmHg DIA: 10 ~ 215mmHg MEAN: 20 ~ 235 mmHg Pediatric: : SYS: 40 ~ 200 mmHg DIA: 10 ~ 150mmHg MEAN: 20 ~ 165 mmHg Neonate: SYS: 40 ~ 135 mmHg DIA: 10 ~ 100mmHg MEAN: 20 ~ 110 mmHg - Static pressure accuracy: ±3mmHg - Resolution: 1mmHg - Accuracy: Maximum Mean error ±5mmHg Maximum Standard deviation ≤8mmHg - Over pressure Protection: Dual protection via software & hardware |
Transportation and Storage Environment - Temperature: -20~50 ºC - Humidity: 10%~90% (non-condensing) - Atmosphere pressure: 86 KPa ~ 110 KPa Safety - IEC60601-1 Approved, CE marking according to MDD93/42/EEC - With reference to RoHS Directive 2011/65/EU recasting Trend & Reviewing - Trend: 168 hours - NIBP measurement reviewing: 500 groups - Waveform review: 100 minutes - Alarm event: 100hours of parameter alarms events and associated parameter ECG - Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V - Gain: 2.5mm/mV(×0.25), 5.0mm/mV(×0.5), 10mm/mV (×1), 20mm/mV (×2), - Sweep speed: 6.25 mm/s12.5 mm/s, 25 mm/s, 50 mm/s - ECG signal range: ±6 mV - Accuracy: ±1bpm/ ±1%, whichever is greater - Resolution: 1 bpm - Leakage Current < 10 μA - Input impedance: > 5.0Mohm - CMRR: Diagnostic Mode >90 dB; Monitor Mode>100dB Surgery Mode>100dB - Baseline Recovery: ≤ 5s after defibrillation (Monitor or Surgery mode) - Bandwidth: Surgery 1 ~ 20Hz Monitor 0.5 ~ 40 Hz Diagnostic 0.05 ~ 130 Hz - Against electrosurgical interference and defibrillation - Indication of Electrode Separation: Every electrode (exclusive of RL) Heart Rate - Measure range: Adult 0bpm; 15 ~ 300 bpm Pediatric: and Neonate: 0bpm; 15 ~ 450 bpm - Resolution: 1 bpm - Accuracy: ± 1% or ± 1bpm, whichever is greater SpO2 (Analog Technic) - Measurement Range: 0 ~ 100 % - Resolution: 1 % - Accuracy: ±2% (70% ~ 100%) Unspecified (0 ~ 69%) Pulse Rate - Measuring and Alarm Range: 20~450bmp - Accuracy: ±3% - Resolution: 1bpm EtCO2 (Mainstream) (Option) - Measure method: Non-dispersive infrared (NDIR) - Measure Range: 0 ~19.7% (0 ~ 150 mmHg) 0 ~ 20 kPa - Resolution: 0.1 mmHg - CO2 Accuracy: 0 ~ 40 mmHg, ±2 mmHg 41 ~ 70 mmHg, ±5% of reading 71 ~ 100 mmHg, ±8% of reading 101~ 150 mmHg, ±10% of reading at 760 mmHg, ambient temperature of 25ºC) - Respiratory Rate: Range: 3 ~150 BrPM Accuracy: ±1 bpm Temperature - Technique: Thermistor probe (2.25K) - Channel: Dual-channel, provide T1; T2; ΔT - Measuring and Alarm Range: 0.0 ºC~ 50 ºC (32ºF~ 122ºF) - Unit: Celsius (ºC), Fahrenheit ( ºF) - Resolution: 0.1ºCor 1ºF - Accuracy: ±0.1ºC(exclusive probe) |