Customization: | Available |
---|---|
Classification: | Imaging Diagnostic Equipment |
Type: | X Ray Equipment |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Configurations
No. | Model | Product Name | Quantity |
1 | CELV-101C | Flat Panel Detector | 1 |
CXDI-801C Wireless | Optional | ||
2 | TS-5 | DX Ray Diagnostic Workstation | 1 |
3 | FSQ-5-3M | High Frequency Generator | 1 |
4 | MXZ1301 | X-Ray Tube | 1 |
5 | XS-1 | Collimator | 1 |
6 | 326-V | Mobile Stand | 1 |
7 | / | Battery Power Unit | 2 |
8 | / | Tablet (Optional) | 1 |
Flat Panel Detector (CELV-101C)
Specifications
• Model: CELV-101C
• Detector Technology: Wireless a-Si Flat Panel Detector
• Scintillator Material: CsI
• Images Size: 350mm x 430mm
• Static Pixel Matrix: 2500 x 3052pixels
• Effective Pixels: 7.60million
• Pixel Size: 140μm
• Spatial Resolution: 3.5lp/mm
• Output Grayscale: 16bit
• Acquisition time: ≤7s
Flat Panel Detector (CXDI-801C Wireless)
Specifications
. Model: CXDI-801C Wireless
. Brand: Canon
. Detector Technology: Wireless a-Si Flat Panel Detector
. Scintillator Material: CsI
. Images Size: 350 x 274mm
. Static Pixel Matrix: 2800 x 2192 pixels
. Effective Pixels: 7.6million
. Pixel Size: 125μm
. Spatial Resolution: 4.0lp/mm
. Output Grayscale: 16bit
. Acquisition Time: ≤6s
. Preview Time : ≤3s
High Frequency Generator
Specifications
• Model: FSQ-5-3M
• Brand: Angell
• Nominal Output Power: 32kW
• Max Output Power: 40kW
• Frequency: 50kHz/60kHz±1Hz
• kV Range: 40-150kV, 1kV step
• mA Range: 50-400mA
• mAs Range: 1-630mAs
• Input power: 220V
X-ray tube
Specifications
• Model: MXZ1301
• Focus: 0.6/1.2mm
• Voltage: 150kV
• Anode Type: Rotating
• Anode Heat Capacity: 300kHU
• Anode Angle: 12°
Mobile Stand
Specifications
• Model: 326-V
• The Vertical Movement Range of X-ray Tube Center along the Column: 580~1800mm
• The Telescopic Movement Range of X-ray Tube Center along the Column Side: 720-1220mm
• Stand Column Horizontal Rotation Range: ±315°
• Collimator Rotation Range along the vertical axis: ±90°
• Mobile Stand Size: 1230 × 580 × 1820 mm
Collimator
Specifications
• Model: XS-1
• Control: Manual
• Filter: 1.2mm Al
• Light: LED lamp
DX Ray Diagnostic Workstation
Specifications
• Model: TS-5
• Display Size: 19inch
• Pixel Matrix: 1280 x 1024pixels
• Patient Management: Manual Registration, WORKLIST Automatic Query.
• Image Acquisition: Automatic Window Adjustment, Automatic Cropping, Automatic Transmission.
• Image Processing: Image correction, Image Flipping.
• Image Observation: Window Width/Level Adjustment, Image Flipping, Image Rotation, Image Scaling, and Restoration.
• Medical Record Report : Automatic Loading of Patient Information
• Film Printing: Support DICOM3.0 Standard Laser Camera Printing.
• DICOM Transfer: Send images to any PACS and workstation that complies with the DICOM 3.0 standard.