Customization: | Available |
---|---|
Classification: | Imaging Diagnostic Equipment |
Type: | Ultrasound Scanner |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Ce Approved 13.3 Inch Hospital Fetal Doppler Ultrasound System with Trolley (YJ-U70T)
1: | Summary of main specifications and system of cart type color Doppler ultrasound |
1.1 | Trolley type all digital color Doppler ultrasonic mainframe |
1.2 | Ultrasonic host operating system: Windows operating system |
1.3 | Applications: Abdomen, obstetrics, gynecology, heart, urinary system, small organs, superficial, blood vessels, pediatrics, newborns, musculoskeletal |
1.4 | Probes: Convex probe, Tran-vaginal probe, Linear probe, Micro-convex probe, Cardiac probe,4D Volume probe |
1.5 | Applications and report: Abdominal, OB, GYN, Cardiac, Urinary, Small Parts, Superficial, Vascular, Pediatrics, Advanced measurement software packages, report software packages, case management software packages, etc. |
☆1.6 | carotid artery intima measurement thickness(IMT) |
☆1.7 | Automatic spectral envelope measurement |
1.8 | Full digital transmission and reception of beam synthesizer |
1.9 | Color Doppler imaging(C) |
1.10 | Pulse-Doppler Imaging(PW) |
☆1.12 | Coherent Contrast imaging(CCI) |
1.12 | Continuous-wave Doppler imaging(CW) |
☆1.13 | B/C/D Real-time three synchronous imaging |
☆1.14 | Power Doppler imaging(PDI) |
☆1.15 | Direct power Doppler imaging(DPDI) |
1.16 | M mode imaging |
☆1.17 | Anatomic M mode imaging |
☆1.18 | Color Doppler M mode imaging |
☆1.19 | Elastography |
☆1.20 | Tissue Doppler imaging(TDI) |
☆1.21 | Strain rate imaging (SRI) |
1.22 | Tissue harmonic imaging(THI) |
1.23 | Fusion harmonic imaging(FHI) |
1.24 | Speckle Reduce imaging(SRI) |
☆1.25 | Panoramic imaging |
☆1.26 | Deflection imaging |
☆1.27 | Trapezoidal imaging |
1.28 | Adaptive velocity optimization |
☆1.29 | Free hand 3D |
1.30 | Real-time 3D imaging(3D/4D) |
1.31 | DICOM3.0 |
1.32 | Monitor:≥21.5 inches, high definition ultrasonic display |
1.33 | ≥13.3-inch touch screen |
1.34 | Physical clipboard: save the image on the left side of the screen, which can be directly saved or deleted. |
1.35 | The system has the function of on-the-spot upgrade |
1.36 | Presupposition: for different inspection of the viscera, preset the inspection conditions for the best image, reduce the adjustment of the operation, and the commonly used external adjustment and combination regulation. |
1.37 | Probe interface: 4 |
1.38 | Chinese and English System, Chinese and English input, optional |
1.39 | Depth:≥360mm; |
1.40 | Extended imaging |
2: | Probes |
2.1Convex probe | Fundamental Frequency:2.0MHz/2.3MHz/2.5MHz/3.0MHz/3.5MHz/4.0MHz/4.6MHz/5.0MHz/5.4MHz, Harmonic Frequency: 4.0MHz/4.6MHz/5.0MHz, |
2.2 Linear probe |
Fundamental Frequency:4.0MHz/4.6MHz/5.0MHz/6.0MHz/7.0MHz/8.0MHz/9.2MHz/10.0MHz/12.0MHz/13.3MHz, Harmonic Frequency: 8.0MHz/9.2MHz/10.0MHz, |
2.3 Trans-vaginal probe | Fundamental Frequency: 3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz/10.0MHz, Harmonic Frequency: 6.0MHz/7.0MHz/8.0MHz, |
2.4 Micro-convex probe | Fundamental Frequency: 3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz, Harmonic Frequency: 6.0MHz/7.0MHz/8.0MHz, |
2.5 Cardiac probe | Fundamental Frequency:1.7MHz/1.9MHz/2.1MHz/2.5MHz/3.0MHz/3.4MHz/3.8MHz/4.2MHz/5.0MHz, Harmonic Frequency: 3.4MHz/3.8MHz/4.2MHz, |
2.6 4D Volume probe | Fundamental Frequency: 2.0MHz/2.5MHz/3.0MHz/3.3MHz/3.7MHz/4.0MHz/5.0MHz/6.0MHz, Harmonic Frequency: 4.0MHz/5.0MHz/6.0MHz, |
3: | 2D imaging mode |
3.1 | Gain:0-100,Step 2 adjustable |
3.2 | TGC:8 segment adjustable |
3.3 | Maximum focus point:≥7, which can be moved throughout the whole process. |
3.4 | Speckle reduction:0-5,5 level |
3.5 | Space Synthesis:0-2,2 level(Liner probe: 3 level, cardiac probe:0) |
3.6 | Dynamic:30-180,35 level,step 5 adjustable |
3.7 | Line density:low,middle,high,3 level |
3.8 | Frame correlation:0-4,4 level |
3.9 | Noise reduction:0-5,5 level |
3.10 | Edge Enhancement:0-5,5 level |
3.11 | Sound power:2-10, 9 level |
3.12 | Greyscale:0-67, 67 level |
3.13 | False-color:0-67,67 level |
3.14 | Image style: Soft-Comparison,2 level |
The screen has a real-time display of voice power, probe frequency, dynamic range, pseudocolor, grayscale, and other 11 parameters can be adjusted | |
4: | Color Doppler imaging mode |
4.1 | Blood gain:0-100,Step 2 |
4.2 | Parameter display: Velocity, Variance |
4.3 | B-Restrain(B/W restrain):0-7, 7 level |
4.4 | Speed Through:0-8, 8 level |
4.5 | Sampling number:6-24, 7 level |
4.6 | Blood flow preferred:0-8, 8 level |
4.7 | Filtering:1-6, 6 level |
4.8 | Sound power:2-6, 4 level |
4.9 | Noise reduction:0-4, 4 level |
4.10 | Smooth treatment:0-4, 4 level |
4.11 | Frame correlation:0-6, 6 level |
4.12 | Chromatography(Blood flow graph):0-37, 37 level |
4.13 | Line density: Low-Middle-High, 3 level |
4.14 | Frequency:4 level adjustable |
4.15 | Velocity:Minimum 0.4K,Maximum 40.5K Convex probe:0.4K-4.3K-38.5K Linear probe:0.4K-14.7K-39.0K Transvaginal probe:0.4K-7.8K-39.7K Volume probe:0.4K-4.2K-34.8K Micro-convex probe:0.4K-10.3K-40.5K cardiac probe:0.4K-7.8K-39.7K |
PS: The frequency of the probe changes and the frequency value changes | |
PS:Frame rate changes with speed | |
5: | Pulse wave Doppler(PW) |
1 | Gain:0-100,Step 2 |
5.2 | Spectrum envelope function: real time automatic spectrum envelope, manual spectrum envelope, and other modes. The system automatically analyses and displays various data such as PSV, EDV, RI, PI, S/D, ACC, HR and so on. Can wake up or close |
5.3 | Sample volume:0.5mm~30mm |
5.4 | Blood angel:-75-75 degree,Step 5 |
5.5 | False color:0-67, 67 level |
5.6 | Dynamic range:20-40, 4 level |
5.7 | Filter:0-9, 9 level |
5.8 | Smooth treatment:1-4, 4 level |
5.9 | Sound power:2-5, 4 level |
5.10 | Volume:0-100, 10 level,Step 10 |
5.11 | Audio filtering:0-4, 4 level |
5.12 | Baseline:-1.0~1.0, |
5.13 | Grey map:0-67, 67 level |
5.14 | Scan velocity:100-500, 6 level |
5.15 | PRF: Minimum 0.5K, Maximum 87.5K Convex probe:0.5K-4.3K-63.3K Linear probe:0.5K-14.5K-78.4K Transvaginal probe:0.5K-8.1K-78.4K Volume probe:0.5K-4.2K-53.8K Micro-convex probe:0.5K-10.3K-81.1K cardiac probe:0.5K-4.3K-87.5K |
5.16 | Frequency:4 level |
PS: The frequency of the probe changes and the PRF value changes | |
PS: The frequency of the probe changes and the frequency value changes | |
6: | Continuous Wave Doppler(CW) |
6.1 | Support probe: Cardiac probe |
6.2 | Adjustment of B mode parameters is switchable |
6.3 | Gain:0-100,Step 2 |
6.4 | Sampling line position is adjustable |
6.5 | PRF:0.9K~36.1K |
6.6 | Baseline:-1.0~1.0 |
6.7 | Blood angel:-75~75 degree |
6.8 | Grey map:0-67 |
6.9 | Scan velocity:100-300 |
6.10 | False color:0-67 |
6.11 | Dynamic range:20-40 |
6.12 | Filtering:0-9,9 level |
6.13 | Smooth treatment:1-4 |
6.14 | Frequency:2.0MHz/2.3MHz/2.5MHz/3.0MHz,4 level adjustable |
6.15 | Sound power:2-5 |
6.16 | Volume:0-100 |
6.17 | Audio Filtering:0-4 |
☆7: | Anatomical M imaging |
7.1 | Support probe: Convex probe, Linear probe, Cardiac probe |
7.2 | Adjustment of B mode parameters is switchable |
7.3 | Gain:0-100,Step 2 |
7.4 | M Sampling line angel is adjustable |
7.5 | M Sampling line length is adjustable |
7.6 | Sampling line:3, Can be displayed or hidden separately |
☆8: | Blood flow M model(MC) |
8.1 | Adjustment of B mode parameters is switchable |
8.2 | Gain:0-100,Step2 |
8.3 | MC Sampling line angle is adjustable |
8.4 | MC Sampling line length is adjustable |
8.5 | Frequency:4 level |
8.6 | Sampling number:6-24 |
8.7 | Speed through:0-8, 8 level |
8.8 | Scan velocity:150-500 |
8.9 | Frame correlation:0-6, 6 level |
8.10 | Filtering:1-6,6 level |
8.11 | Blood flow preferred:0-8,8 level |
8.12 | Smooth treatment:0-4,4 level |
8.13 | Map:0-37, 37 level |
☆9: | Elastography |
9.1 | Adjustment of B mode parameters is switchable |
9.2 | Gain:0-100,Step 2 |
9.3 | B/E, Double real-time display on the same screen |
9.4 | Probe displacement curve display: Up/Down |
9.5 | Pressure indicator bar display |
9.6 | Frequency:8-9 level, Adjustable; According to the probe display |
9.7 | Noise reduction:0-2, 2 level |
9.8 | Frame correlation:0-3, 3 level |
9.9 | Comparison:0-13, 13 level |
9.10 | False-color:0-3, 3 level |
9.11 | Don't support cardiac probe |
☆10: | Tissue Doppler imaging(TDI) |
10.1 | Support probe: Cardiac probe |
10.2 | Adjustment of B mode parameters is switchable |
10.3 | Gain:0-100,step 2 |
10.4 | ROI area adjustable |
10.5 | Sampling number:6-24 |
10.6 | Velocity:0.4K-8.0K |
10.7 | Frame correlation:0-6,6 |
10.8 | Tissue preferred:0-7, 7 level |
10.9 | Frequency:2.0MHz/2.3MHz/2.5MHz/3.0MHz |
10.10 | Support color reversal |
☆11: | Strain rate imaging |
11.1 | Support probe: Cardiac probe |
11.2 | Adjustment of B mode parameters is switchable |
11.3 | ROI area adjustable |
11.4 | Gain:0-100,Step 2 |
11.5 | Sampling number:6-24,6 level |
11.6 | Axial average:1-4, 4 level |
11.7 | Velocity:0.4K-8K |
11.8 | Frame correlation:0-6, 6 level |
11.9 | Tissue optimization:0-7,7 level |
☆12: | Panoramic imaging |
12.1 | Support probe: Linear probe |
12.2 | Speckle Reduction:0-5, 5 level |
☆13: | Deflection imaging |
13.1 | Support probe: Linear probe |
13.2 | Adjustment of B mode parameters is switchable |
13.3 | Deflection angel:8 level |
13.4 | Speckle reduction:0-5, 5 level |
13.5 | Dynamic rate:30-180,Step 5 |
13.6 | Line density:low-middle-high,3 level |
13.7 | Frame Correlation:0-4, 4 level |
13.8 | False-color:0-67, 67 level |
13.9 | Image style:Soft-Comparison,2 level |
13.10 | Noise reduction:0-5, 5 level |
13.11 | Edge Enhancement:0-5,5 level |
13.12 | Sound power:2-10,8 level |
13.13 | Grey map:0-67,67 level |
☆14: | Trapezoidal imaging |
14.1 | Probe support: linear probe |
14.2 | Adjustment of B mode parameters is switchable |
14.3 | Deflection angel:8 level |
14.4 | Speckle reduction:0-5, 5 level |
14.5 | Dynamic rate:30-180,Step 5 |
14.6 | Line density:low-middle-high,3 level |
14.7 | Frame Correlation:0-4, 4 level |
14.8 | False-color:0-67, 67 level |
14.9 | Image style:Soft-Comparison,2 level |
14.10 | Noise reduction:0-5, 5 level |
14.11 | Edge Enhancement:0-5,5 level |
14.12 | Sound power:2-10,8 level |
14.13 | Grey map:0-67, 67 level |
14.14 | Space Synthesis:0-2, 2 level |
☆15 | Freehand 3D imaging |
15.1 | Support probe: convex probe, linear probe |
15.2 | Display model: 4 pictures |
15.3 | Image Rotation X/Y/Z Axis |
15.4 | Multi-slice Visibility |
16 | Real-time 4D imaging |
16.1 | Support probe: 4D volume probe |
16.2 | Adjustment of B mode parameters is switchable |
16.3 | Gain:0-100,Step 2 |
16.4 | Display model: one image, two images, four images |
16.5 | Image Rotation:X/Y/Z-Axis |
16.6 | Multi-slice Visibility |
16.7 | Light&Shade inversion |
16.8 | Smooth:0-4, 4 level |
16.9 | Threshold level:0-129, Step 3 |
16.10 | Transparency:1-509,Step 10 |
16.11 | Render type:4 kinds,Surface,maximum,minimum,perspective |
17: | Extended Imaging |
17.1 | Gain:0-100,Step 2 |
17.2 | TGC:8 segment adjustable |
17.3 | Maximum focus point:≥7, which can be moved throughout the whole process. |
17.4 | Speckle reduction:0-5,5 level |
17.5 | Space Compound:0-2,2 level(Linear probe: 3 level,don't support cardiac probe) |
17.6 | Dynamic range:30-180,35 level,Step 5 |
17.7 | Line density:Low,Middle,High,3 level |
17.8 | Frame correlation:0-4,4 level |
17.9 | Noise reduction:0-5,5 level |
17.10 | Edge enhancement:0-5,5 level |
17.11 | Sound power:2-10, 9 level |
17.12 | Grey map:0-67, 67 level |
17.13 | False color:0-67,67 level |
17.14 | Image style:Soft-Comparison,2 level |
17.15 | Extended level: Maximum 72 level Convex probe:9 level Trans-vaginal probe:72 level Micro-convex probe:29 level Cardiac probe:40 level 4D Volume probe:17 level |
PS: The screen has the real-time display of voice power, probe frequency, dynamic range, pseudo color, gray scale, and other 11 parameters can be adjusted | |
PS: When the probe scan range reaches the maximum, the space synthesized is 0. | |
18: | Measurement and analysis function: |
18.1 | General measurement: Distance, area, ellipse, cross line, angle, distance ratio, volume, Volume (ellipse), area ratio, diameter, joint angle |
18.2 | Cardiac:Automatic spectrum envelope,LV,Main Pulmonary artery diameter,RVEDd,RVEDs,LVM,LAV,HR,MVF,AO,AR,LVOT,TVF,Pulmonic valve,Pulmonary vein,RV,Doppler fetal heart sound,LVET,LVM,LVMI,AV |
18.3 | Vascular: carotid intima (IMT), length stenosis ratio, area stenosis ratio, IMT (back wall), IMT (front wall) |
18.4 | OB:Fetal routine,AFI,TW,GS,CRl,OFD,HL,ulna,NT,Fibula,Nbonel,Radial,Tibia |
18.5 | GYN:uterus,cervix,corpus uteri/cervix uterus,left ovarian vein,right ovarian vein,dominant follicle,intima thickness |
18.6 | Urology: prostate,residual urine,left kidney,right kidney,left suprarenal vein,right suprarenal,left testis,right testis,left seminal vesicle,right seminal vesicle |
18.7 | Abdomen:liver,CHD,partial vein diameter,cholecyst,CBD,pancreas,spleen,Internal diameter of abdominal aorta,kidney |
18.8 | Small parts: Thyroid |
18.9 | Software package: Measurement package, Software package, Medical records management software package |
19: | Graphic and text management system |
19.1 | Host build in 2 hard disks (SSD 120+1T), Start fast and stable |
19.2 | Movie playback:≥1200 frames |
19.3 | Internal file information management system: can record patient number, name, check number, check the date and so on, and can be searched and managed by numbering, checking number, name and so on. |
19.4 | Type of report is 16 |
19.5 | One key fast report graphic and text management |
20: | Interface |
20.1 | USB interface: 4 |
20.2 | HDMI interface: 1 |
20.3 | RJ-45 interface:1 |
20.4 | Grounding wire interface:1 |
20.5 | DVD RW:1 |
21: | Configuration |
21.1 | Trolley type full digital color Doppler ultrasound diagnostic system |
21.2 | Probe: convex array probe (standard), linear probe (optional), Trans-vaginal probe (optional), cardiac probe (optional), 4D volume probe (optional) |
21.3 | ≥13 quick-adjusting knobs |
22: | Technology, after-sales service and other requirements |
22.1 | After acceptance, the warranty is free for two years(Provide manufacturer warranty certificate) |
22.2 | The manufacturer has ISO13485 certification and EU CE certification. |
ICU Equipment | Lab equipment | Medical image | Medical Cold Chain |
anesthesia machine | Biochemistry Analyzer | Ultrasound system | BBR |
Medical ventilator | Hematology analyzer | X-ray | Deep freezer |