Opti Medical Systems Opti CCA-Ts2 Blood Gas Electrolyte Analyzer

Product Details
Customization: Available
Classification: Biological Diagnostics
Type: Blood Gas Electrolyte Analyzer
Still deciding? Get samples of US$ 7700/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 14001, QC 080000, ISO 13485, EICC
International Commercial Terms(Incoterms)
FOB, CIF, CFR
  • Opti Medical Systems Opti CCA-Ts2 Blood Gas Electrolyte Analyzer
  • Opti Medical Systems Opti CCA-Ts2 Blood Gas Electrolyte Analyzer
  • Opti Medical Systems Opti CCA-Ts2 Blood Gas Electrolyte Analyzer
  • Opti Medical Systems Opti CCA-Ts2 Blood Gas Electrolyte Analyzer
  • Opti Medical Systems Opti CCA-Ts2 Blood Gas Electrolyte Analyzer
  • Opti Medical Systems Opti CCA-Ts2 Blood Gas Electrolyte Analyzer
Find Similar Products

Basic Info.

Model NO.
YJ-BG80
Certification
CE, EEC, MSDS, ISO13485
Group
Middle-aged and Old
Name
Blood Gas Electrolyte Analyzer
Model
Yj-Bg80
Sample Type
Whole Blood, Serum, Plasma, Dialysate, Csf
Test Items
pH/Pco2/Po2/K+/Na+/Ci-/Ca++/Hct
Power Supply
100-240V
Power
150va
Application
hospital, Laboratory
Warranty
1 Year
Language
English & Spanish
Input Parameters
Hb, B.P., Patient Temp. , Fio2
Gas Tank Free
One Set Free Reagents
Transport Package
Wooden Box
Specification
69.6KGS
Trademark
FORERMED
Origin
Henan
HS Code
9027809900
Production Capacity
1000 Sets/Month

Product Description

Blood Gas Analyzer, Blood gas electrolyte analyzer
Opti Medical Systems Opti CCA-Ts2 Blood Gas Electrolyte Analyzer




Features of our Blood Gas Analyzer

Sample Type

Whole blood, Serum, Plasma, Dialysate, CSF

Model name & test items

80 ( pH/pCO2/pO2/K+/Na+/CI-/Ca++/Hct )

80A(pH/ pCO2/ pO2 /Hct )

80B ( pH/pCO2/pO2/K+/Na+/CI-/Hct )

80E ( pH/pCO2/pO2/K+/Na+/CI-/Ca++/Hct /Glu/Lac)

80Q ( pH/pCO2/pO2/K+/Na+/CI-/Ca++/Hct Auto QC)

80AQ ( pH/pCO2/pO2/Hct Auto QC)

80BQ ( pH/pCO2/pO2/K+/Na+/CI-/Hct Auto QC)
 

Test parameters:pO2,pCO2,pH,K+,Na+,Cl-,Ca+, HCT

Gas tank free-More convenient

Self made maintenance free electrodes

All in one reagent pack

Auto QC as optional

Touch screen and user friendly.

Unrivalled economical cost per test to ensure more benefits in the long run.

Gas tank free

More parameters: pO2, pCO2, pH, K, Na, Cl, Ca, HCT

Auto QC as optional

All in one reagent pack

Self-made maintenance-free electrodes

Economic cost per test
 

Working environment for Hospital Medical Blood Gas Electrolyte Analyzer

Working temperature:15ºC~30ºC Storage environment:5ºC~45ºC

Power supply:100-240V~±10&,50/60±1Hz

Dimension (W*H*D)

Instrument: 400mm×574mm×344mm

CAL PAK: 258mm×180mm×70mm

Auto QC: 103mm×180mm×70mm

Weight: 18KG

 

Main Characteristics for Hospital Medical Blood Gas Electrolyte Analyzer

Ø Multi-combination parameters

Ø Self-made maintenance free electrodes

Ø Both for syringes & capillary

Ø 50UL for capillary, 95UL for whole blood

Ø 1 min from the aspiration to result

Ø Long-lasting fluid system

Ø All-in-one design calibrate cartridge with multi-sizes for different levels customer's demand.

Ø Cartridge expiration alarm & residue

Ø Preheats reagents & sample

Ø Optional Auto QC cartridge with H/M/L level

Ø Data storage >10,000

Ø Colorful touch screen with high resolution

Ø Friendly operation interface

Ø Infrared human-detector

Ø Rich data management interface

Ø Battery backup

Ø Available for build-in thermal printer and external printer

Ø Convenient bar-code system management

Ø Economic cost per test

 

Measured Parameters

Analyte Measuring range Unit
PH 6.000-9.000 pH scale
Carbon dioxide 0.667-26.67 kpa
Partial pressure 5.0-200.0 mmHg
pO2 0-106.7 kpa
0-800.0 mmHg
K+ 0.5-15.0 mmol/L
Na+ 50.0-200.0 mmol/L
CI- 20.0-200.0 mmol/L
Ca++ 0.10-5.0 mmol/L
Hct 12.0-65.0 mmol/L
B.P. 500-800 mmHg
Glucose 1.1-66.7 Mmol/L
Lactate 0.4-30.0 Mmol/L

Opti Medical Systems Opti CCA-Ts2 Blood Gas Electrolyte Analyzer
 
1.Thermal Printer
2.Interface
3.Cooling Fan
4.Power In/Socket
5.Switch
6.Battery

NO.1 and Unique In China
Gas tank free
More parameters: pO2, pCO2, pH, K, Na, Cl, Ca, HCT
Auto QC as optional
All in one reagent pack
Self-made maintenance-free electrodes
Economic cost per test

 

BG80 Blood gas analyzer
Feature:

  Test parameters:pO2,pCO2,pH,K+,Na+,Cl-,Ca+, HCT
  Gas tank free-More convenient
  Self made maintenance free electrodes
  All in one reagent pack
  Auto QC as optional
  Touch screen and user friendly.
  Unrivalled economical cost per test to ensure more benefits in the long run.

 

CONFIGURATION:
 
BG80: pO2, pCO2, pH, K, Na, Cl, Ca, HCT
 
BG80A: pO2, pCO2,HCT
           
BG80B: pO2, pCO2, pH, K, Na, Cl, HCT

 Blood gas analyzer Feature for Blood  Gas Automatic Electrolyte Analyzer:

Test parameters:pO2,pCO2,pH,K+,Na+,Cl-,Ca+, HCT

Gas tank free-More convenient

Self made maintenance free electrodes

All in one reagent pack

Auto QC as optional

Touch screen and user friendly.

Unrivalled economical cost per test to ensure more benefits in the long run.

Gas tank free

More parameters: pO2, pCO2, pH, K, Na, Cl, Ca, HCT

Auto QC as optional

All in one reagent pack

Self-made maintenance-free electrodes

Economic cost per test

 

Working environment for Blood  Gas Automatic Electrolyte Analyzer

Working temperature:15ºC~30ºC Storage environment:5ºC~45ºC

Power supply:100-240V~±10&,50/60±1Hz

Dimension (W*H*D)

Instrument: 400mm×574mm×344mm

CAL PAK: 258mm×180mm×70mm

Auto QC: 103mm×180mm×70mm

Weight: 18KG

  

Main Characteristics for Blood  Gas Automatic Electrolyte Analyzer

Ø Multi-combination parameters

Ø Self-made maintenance free electrodes

Ø Both for syringes & capillary 

Ø 50UL for capillary, 95UL for whole blood

Ø 1 min from the aspiration to result

Ø Long-lasting fluid system

Ø All-in-one design calibrate cartridge with multi-sizes for different levels customer's demand.

Ø Cartridge expiration alarm & residue

Ø Preheats reagents & sample

Ø Optional Auto QC cartridge with H/M/L level

Ø Data storage >10,000

Ø Colorful touch screen with high resolution

Ø Friendly operation interface

Ø Infrared human-detector

Ø Rich data management interface

Ø Battery backup

Ø Available for build-in thermal printer and external printer

Ø Convenient bar-code system management

Ø Economic cost per test

 

Measured Parameters for Blood  Gas Automatic Electrolyte Analyzer

Analyte Measuring range Unit
PH 6.000-9.000 pH scale
Carbon dioxide 0.667-26.67 kpa
Partial pressure 5.0-200.0 mmHg
pO2 0-106.7 kpa
0-800.0 mmHg
K+ 0.5-15.0 mmol/L
Na+ 50.0-200.0 mmol/L
CI- 20.0-200.0 mmol/L
Ca++ 0.10-5.0 mmol/L
Hct 12.0-65.0 mmol/L
B.P. 500-800 mmHg
Glucose 1.1-66.7 Mmol/L
Lactate 0.4-30.0 Mmol/L

 

 

 For more help and recommendation about Blood  Gas Automatic Electrolyte Analyzer please contact us. 
Opti Medical Systems Opti CCA-Ts2 Blood Gas Electrolyte Analyzer
Opti Medical Systems Opti CCA-Ts2 Blood Gas Electrolyte Analyzer

Team

√ Speak fluent English


√ Well-trained and professional sales


√ More than 10 years of experience engineers

Opti Medical Systems Opti CCA-Ts2 Blood Gas Electrolyte Analyzer
 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More