Customization: | Available |
---|---|
Certification: | CE, ISO13485 |
Model No.: | Yj-Dm156b |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
High Frequency Generator | Specifications * Model: FSQ-M-VMX1 * Power Supply: 5kW * Output Voltage: 20 - 40kV * Input Voltage: 220V * Range of Current: 10-200mA * Range of mAs: 10 - 120mAs (Small focus) * Range of mAs: 10 - 500mAs (Large focus) * Frequency: 50/60KHZ * Work Mode: Intermittent * Power Requirement: 180-264V AC |
X-Ray Tube |
Specifications
* Model: QG-M2 * Focus: 0.1 / 0.3mm
* Anode Heat Storage Capacity: 300kHU * Target Surface: RT-TZM Target * Anode type: Rotating |
Compression Device |
Specifications
* Model: YPQM-1/YPQM-2/YPQM-3 * Maximum Height: 280mm * Compressor Size: 240mm × 310mm (YPQM-1) * Compressor Size: 100mm × 100mm (YPQM-2) * Compressor Size: 200mm × 280mm (YPQM-3) (Optional) * Pressure: 0 - 196N
* Compressor: Automatic Release Function and Manual Control Function
|
Grid | Specifications * Model: JPI 2100 * Grid Density: 332.5 Line/Inch(±1) * Grid Ratio: 4 : 1 * Focus: 645mm |
Collimator | Specifications * Model: XSM-2 * Filter: 0.1mm Al (28KV) |
X-ray Imaging System | Specifications * Model: CareView 750M * Detector Technology: a-Si Flat Panel Detector * Scintillator Material: CsI * Detector Size: 240 x 300mm * Static Pixel Matrix: 4096 x 3072pixels * Pixel Size: 77μm * Grayscale: 16 bit * Preview Image: ≤ 5s * Spatial Resolution: 6 lp/mm * AEC Function |
C-Arm Stand | Specifications * Model: DM156-1 * FID: 1420 - 2020mm * Angle Range of Arm Rotation: -135° - +180° * SID: 650mm * Range of Arm Up and Down: 0-600mm * One-click Function * Isocentric motion |
DX Ray Diagnostic Workstation | Specifications * Model: TSM-1 * CPU: Dual-Core 3.7G * RAM: 4G * Hard Disk: 500G * Display: 2M Medical Grade & 24-inch LCD Monitor * Registration management, image acquisition, image viewer, image processing, film printing, system settings * DICOM connection, original data, DICOM data storage * Distance measurement, angle measurement, adjustment of image contrast and brightness , image rotation, image flip, negative image, image distortion correction * Supports Standard DICOM Printer |
Configurations
|
|||
No.
|
Model
|
Product Name
|
Quantity
|
1
|
TSM-1
|
DX Ray Diagnostic Workstation
|
1
|
2
|
CareView 750M
|
X-ray Imaging System
|
1
|
3
|
FSO-M-VMX1
|
High Frequency Generator
|
1
|
4
|
QG-M2
|
X-Ray Tube
|
1
|
5
|
XSM-2
|
Collimator
|
1
|
6
|
DM156-1
|
C-Arm Stand
|
1
|
7
|
YPOM-1/YPOM-2
|
Compression Device
|
2
|
8
|
FSE1200022/FSROWO 0000/FSLOW00000 |
Foot Switch (A set of two)
|
1
|
9
|
/
|
High Voltage Cables
|
2
|
10
|
/
|
Emergency Brake Switch
|
1
|
11
|
/
|
Patient Handle
|
1
|
12
|
/
|
Display
|
2
|
13
|
/
|
Computer
|
2
|
14
|
/
|
Report Laser Printer
|
1
|