Customization: | Available |
---|---|
Classification: | Imaging Diagnostic Equipment |
Type: | X Ray Equipment |
Still deciding? Get samples of US$ 65000/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Standard configuration:: | |
Remote console (with touch screen control) | 1 set |
high-voltage generator | 1 set |
Toshiba X-ray Tube | 1set |
Electric multi-leaf collimator | 1 set |
Diagnostic Bed | 1set |
TOSHIBA Three Field image intensifier | 1set |
Germany BASLER CCD Camera | 1set |
Medical HD monitor | 1set |
High voltage cable | 2sets |
workstation | 1set |
Item | Content | Technical parameter | |
Power supply | Voltage | 380V±38V | |
Frequency | 50Hz±1Hz | ||
Capacity | ≥65kVA | ||
internal resistor | ≤0.17Ω | ||
Digital X-ray high voltage system (import high-frequency generator ) |
photography | Power Output | 80KW |
Inverter Frequency | 440KHZ | ||
Tube Voltage | 40kv-150kv step regulation | ||
Tube Current | 10mA-1000mA step regulation | ||
Exposure time | 1.0s-10000ms step regulation | ||
Control interface | Touched LCD | ||
Control hand | One-button operation handle | ||
fluoroscopy | Tube Voltage | 40kv-120kv ontinuous regulation | |
Tube Current | 0.5mA-10 mA continuous regulation 0.5mA-20 mA Pulse regulation |
||
Digital Controlled X-ray Tube |
Tube Brand | Toshiba E7869X | |
Tube Focus:Large Focus/Small Focus | 1.2mm /0.6mm | ||
Input Power | Large focus: 100KW small focus: 40kW | ||
thermal capacity | 600 KHU | ||
Rotary anode speed | 9700rpm | ||
Micro-computer control remote diagnostic table |
Material of the tabletop | high strength,low absorb carbon fiber | |
Rotation of the table | 90°~0°~ -25° | ||
Table Size | 2100*796 mm | ||
Transverse travel of table | 220mm | ||
Longitudinal travel of the photography holder and film spot device | ≥720mm | ||
Table to Floor distance | 900mm | ||
X-ray Focus-film gauge | 1100 mm-1500 mm | ||
Rotating foot plate | ±360° rotation | ||
Full film photography size | 8″×10″-14″×17″ | ||
Compressor force | 80N-130N | ||
Dividing method for spot film | Full film, half dividing, three parts dividing, four parts dividing | ||
Control method for diagnostic table | Remote,table control,frequency conversion soft starting and stopping | ||
beam limiter | Electric Multi-leaf | ||
fixed bucky device for table | Grid density: 103L/INCH, Grid ratio: 10:1,focusing distance: 120cm,fixed type: 15″×18″ | ||
TOSHIBA Intensifier and Monitor | Image Intensifier | Toshiba (9"/6"/4.5″) Image Intensifier | |
high resolution CCD (digital cameras) | ultra-low-light,standard 2000,000 pixel from Germany BASLER | ||
Monitor (Optional ) | 14'' medical high definition monitor, horizontal central resolution ratio :1000 lines,fringe: 800 lines,video bandwidth: 12.5MHz,50bit,image number/second: 25 frame | ||
workstation | i5-6400(3.20 GHz),48 GB DDR3, 1T SATA (7200 rpm), work list ; DSI function; Gather and deal with image ;Spot Film Acquire Image ;Image Playback ;Rich Image Processing Function ;X-ray Film Printer Function : Report Edit and Print Function ; | ||
LCD colorful screen | 19" LED Medical Use High Definition Monitor |
Digital Flat Panel Detector |
Flat Panel Detector | PLD-1417V |
Active area | 343(H)×416(V) | |
Pixel matrix: | 2304(H)×2800(V) | |
Pixel pitch: | 150 μm | |
Cycle time: | 6S | |
Limiting resolution | Min. 3.4 line pair/mm | |
A / D transition: | 14 bit | |
Energy range | 40 - 150 kVp | |
Maximum entrance dose (low gain) | 4 mR / frame | |
Data output | 16-bit digital output Ethernet(1000BASE - T) | |
Exposure Synchronous control: | outside | |
power Input: | DC 24V 2A |