Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Classification: | Imaging Diagnostic Equipment |
| Type: | X Ray Equipment |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency








| Standard configuration:: | |
| Remote console (with touch screen control) | 1 set |
| high-voltage generator | 1 set |
| Toshiba X-ray Tube | 1set |
| Electric multi-leaf collimator | 1 set |
| Diagnostic Bed | 1set |
| TOSHIBA Three Field image intensifier | 1set |
| Germany BASLER CCD Camera | 1set |
| Medical HD monitor | 1set |
| High voltage cable | 2sets |
| workstation | 1set |
| Item | Content | Technical parameter | |
| Power supply | Voltage | 380V±38V | |
| Frequency | 50Hz±1Hz | ||
| Capacity | ≥65kVA | ||
| internal resistor | ≤0.17Ω | ||
| Digital X-ray high voltage system (import high-frequency generator ) |
photography | Power Output | 80KW |
| Inverter Frequency | 440KHZ | ||
| Tube Voltage | 40kv-150kv step regulation | ||
| Tube Current | 10mA-1000mA step regulation | ||
| Exposure time | 1.0s-10000ms step regulation | ||
| Control interface | Touched LCD | ||
| Control hand | One-button operation handle | ||
| fluoroscopy | Tube Voltage | 40kv-120kv ontinuous regulation | |
| Tube Current | 0.5mA-10 mA continuous regulation 0.5mA-20 mA Pulse regulation |
||
| Digital Controlled X-ray Tube |
Tube Brand | Toshiba E7869X | |
| Tube Focus:Large Focus/Small Focus | 1.2mm /0.6mm | ||
| Input Power | Large focus: 100KW small focus: 40kW | ||
| thermal capacity | 600 KHU | ||
| Rotary anode speed | 9700rpm | ||
| Micro-computer control remote diagnostic table |
Material of the tabletop | high strength,low absorb carbon fiber | |
| Rotation of the table | 90°~0°~ -25° | ||
| Table Size | 2100*796 mm | ||
| Transverse travel of table | 220mm | ||
| Longitudinal travel of the photography holder and film spot device | ≥720mm | ||
| Table to Floor distance | 900mm | ||
| X-ray Focus-film gauge | 1100 mm-1500 mm | ||
| Rotating foot plate | ±360° rotation | ||
| Full film photography size | 8″×10″-14″×17″ | ||
| Compressor force | 80N-130N | ||
| Dividing method for spot film | Full film, half dividing, three parts dividing, four parts dividing | ||
| Control method for diagnostic table | Remote,table control,frequency conversion soft starting and stopping | ||
| beam limiter | Electric Multi-leaf | ||
| fixed bucky device for table | Grid density: 103L/INCH, Grid ratio: 10:1,focusing distance: 120cm,fixed type: 15″×18″ | ||
| TOSHIBA Intensifier and Monitor | Image Intensifier | Toshiba (9"/6"/4.5″) Image Intensifier | |
| high resolution CCD (digital cameras) | ultra-low-light,standard 2000,000 pixel from Germany BASLER | ||
| Monitor (Optional ) | 14'' medical high definition monitor, horizontal central resolution ratio :1000 lines,fringe: 800 lines,video bandwidth: 12.5MHz,50bit,image number/second: 25 frame | ||
| workstation | i5-6400(3.20 GHz),48 GB DDR3, 1T SATA (7200 rpm), work list ; DSI function; Gather and deal with image ;Spot Film Acquire Image ;Image Playback ;Rich Image Processing Function ;X-ray Film Printer Function : Report Edit and Print Function ; | ||
| LCD colorful screen | 19" LED Medical Use High Definition Monitor | ||
Digital Flat Panel Detector |
Flat Panel Detector | PLD-1417V |
| Active area | 343(H)×416(V) | |
| Pixel matrix: | 2304(H)×2800(V) | |
| Pixel pitch: | 150 μm | |
| Cycle time: | 6S | |
| Limiting resolution | Min. 3.4 line pair/mm | |
| A / D transition: | 14 bit | |
| Energy range | 40 - 150 kVp | |
| Maximum entrance dose (low gain) | 4 mR / frame | |
| Data output | 16-bit digital output Ethernet(1000BASE - T) | |
| Exposure Synchronous control: | outside | |
| power Input: | DC 24V 2A |