Customization: | Available |
---|---|
Classification: | Physiological Functions of Diagnosis and Monitoring Equipment |
Type: | Patient Monitor |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Core *Newly advanced A9 main board with Linux OS, calculating speed is 4 times faster than traditional products *Support storage of 25000 groups of medical record and 8640 hours trend review Body *12.1 inch Folded high-brightness TFT LED *Optional touch screen *Humanized probe frame design Sensor *12-Crystal ultrasound transducer achieves a wider focal region for more uniform coverage at greater depths than conventional 9-crystal. 12-crystal ultrasound design can also get good result even when the patient varies her position and shape *Optional waterproof FHR transducer for underwater birth *Event Marker for easy documentation of events and kick counts. Auto-fetal-movement detector is also available. *Use of signal strength indicator to position the ultrasound transducers at the optimum location on the patient Printer *Built-in high-speed thermal printer, printing width can be set to 112mm, 150mm, can meet both US standard and European standard (Brand: SEIKO, Japan) *Support fast printing of stored trend Central System *Optional Build-in wireless network module, supporting wired or wireless connection to the central monitoring station. *Optional Support HL7 (Health Level Seven) |
Alarm *Three-level acousto-optic alarm *FHR signal strength prompt *Cross-Channel Verification (CCV) provides visual and audible indication when it detects synchronous fetal or maternal heart rate signals, indicating that you may be monitoring a duplicate signal) *Sensor-off alarm *Paper out alarm *Support alarm review Linux OS *Support operation with mouse and computer keyboard (option) *Multi-display mode to meet different clinical requirement, including Fetal-parameter interface, Maternal-parameter interface, Fetal/Maternal-parameter interface, as well as big font, alarm review, ECG review, trend table, trend graph and OxyCRG display. *NIBP self-test mode: including overpressure test, static pressure test and air leakage test. *On-screen scrolling for viewing stored fetal traces *Generate ID automatically when register a new patient *Support medical history search by patient ID, name and mobile number *NST Timer *Fetal Movement Profile (FMP) detects and automatically records gross fetal body movements *Heart rate offset mode allowing you to offset FHR2 ± 5~30BPM. *Support multi-language display *Advanced Fischer NST Report (Fetal Health Report) *Support online software upgrading by net/USB *Optional patient data/NST Report backup by USB in PDF format |
Dimension and Weight - Dimension: 360mm*310mm*120mm - Weight: 5.3kg(excluding accessories) Power Supply - Voltage: AC100~240V, 50/60HZ Display - 12.1" color TFT LED (0-90° rotation) - Resolution: 1024*768 pixels Battery (Built-in) - Type: Rechargeable lithium battery 14.8V/2200mAh - Charge Cycle: ≥500 times - Working time: 2 hours Recorder (Built-in) - Method: Thermal printer - Paper: Z-fold, thermosensitive - Paper width: 112 mm (4.41 in)/150 mm (5.91 in) - Printing speed: 1/2/3cm/min - Trace: Max. 4 tracks - Recording way: Real-time Recording, Review Printing Alarm - Level: Low, medium and high - Indication: Auditory, Visual, Delay of FHR Alarm Input Device - Touch screen (option) - Knob (Standard) - Keypad input (Standard) - Mouse/ Keyboard input (option) - USB port for patient data/NST report backup (option) System Output & Extensible Interface - Ethernet Network: 1 standard RJ45 socket - USB Port: 2 - Video Output: 1 HDMI port (option) Trend & Reviewing - Cardiotocography (CTG): Waveform Review: 8640 hours - Vital Signs: Trend: 2160 hours Waveform Review: 2 hours NIBP Review: 2000 groups - Alarm Review: 2000 groups Safety - IEC60601-1 Approved, CE marking according to MDD93/42/EEC - With reference to RoHS Directive 2011/65/EU recasting |
- Ultrasound (FHR) - Transducer type: 12-Crystal ultrasound transducer - Measure method: Wide beam pulse doppler - FHR Measurement range: 30 to 240 bpm (US Standard) 50 to 210 bpm (Europe Standard) - Accuracy: ±1 bpm - Intensity: <3 mW/cm2 - Ultrasound frequency: 1MHz±3% - Resolution: 1 bpm TOCO - Measurement method: Strain gauge sensor element - Measure range: 0 ~ 100 units - Resolution: 1 unit - Nonlinear deviation : ≤±8% - Baseline setting: 0,5,10,15, 20 can be selected - Auto offset correction: 3 second after connecting the transducer - Auto zero adjust: TOCO value is set to zero negative following a negative Measure value for 5 seconds Fetal Movement Recording - Automatic fetal movement (AFM): pulsed doppler ultrasound - Automatic fetal movement autograph - Manual fetal movement marker (MFM) Maternal ECG - Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V - Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV, Auto - Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50 mm/s - Accuracy: ±1bpm/ ±1%, whichever is greater - Resolution: 1 bpm - Leakage Current < 10 μA - CMRR: Diagnostic Mode >89 dB Monitor Mode >105 dB Surgery Mode >105 dB - Bandwidth: Surgery 1 ~ 25 Hz Monitor 0.5 ~ 40 Hz Diagnostic 0.05 ~ 120 Hz Maternal Heart Rate - Measure range: Adult: 0bpm; 10 ~ 300 bpm Neonate: 0bpm; 10 ~ 350 bpm - Resolution: 1 bpm - Accuracy: ± 1% or ± 1bpm, whichever is greater ST Measurement - Range: -2.0 ~ +2.0 mV - Accuracy: -0.8mV ~ +0.8mV: ±0.02mV or ±10%, whichever is greater - Other range: unspecified - Resolution: 0.01mV |
Maternal Respiration - Method: Impedance between RA-LL, RA-LA - Gain: ×0.25, ×0.50, ×1, ×2, ×4 - Respiration Rate: 0bpm, 6 ~ 150 bpm - Resolution: 1 bpm - Accuracy: ±2 bpm or ±2%, whichever is greater - Apnea Alarm: 10 ~ 60 s Maternal SpO2 (Digital Technic) - Measurement Range: 0 ~ 100 % - Resolution: 1 % - Accuracy: ±2% (70% ~ 100%) ±3 % (35% ~ 69%) Unspecified (0 ~ 34%) Pulse Rate - Range: 25~250bpm - Accuracy: ±1% or ±1 bpm, whichever is greater - Resolution: 1bpm Maternal NIBP (MNIBP) - Method: Oscillometric - Measure mode Manual, Auto, STAT - Measure Interval in AUTO Mode 1~480 min - STAT mode cycle time: - Keep 5 minutes, at 5 seconds interval - Measure and Alarm Range: Systolic: 30~270 mmHg Diastolic: 10~220 mmHg Mean: 20~235 mmHg - Static pressure accuracy ±3mmHg - Resolution: 1mmHg - Accuracy: Maximum Mean error ±5mmHg Maximum Standard deviation 8mmHg - Over pressure Protection: Dual protection via software & hardware Maternal Temperature - Technique: Thermistor probe (2.25K) - Measuring and Alarm Range: 0.0 ºC~ 50 ºC (32ºF~ 122ºF) - Unit: Celsius (ºC), Fahrenheit ( ºF) - Resolution: 0.1ºC - Accuracy: ±0.1ºC NST Report/FHR Interpretation (Option) - Based on Fischer Evaluation Method (monitoring time≥20 Min) - Average Baseline FHR /Number of Acceleration /Number of Deceleration /Number of Small Acceleration /Amplitude Variation /Number of PV - Automatic Score Result: Sore: 8-10 (Excellent) Sore: 5-7 (Suspicious) Score:≤4 ( Fetus Hypoxia) * Specifications subject to change without prior notice |