Product Description
Multiparameter Patient monitor Portable Patient vital signs monitor
Product Parameters
ECG
5 Leads: RA, LA, LL RL, V
Gain: x 1.25 mm/mV, 2.5 mm/mV.
5.0 mm/mV, 10 mm/mV,
20mm/mV (error ≤ 5%)
Sweep speed: 6.25mm/s.
12.5mm/s,25mm/s,50mm/s (error ≤ ± 10%)
Bandwidth: Surgery 1~25 Hz
Monitor 0.5~40 Hz
Diagnostic 0.05-130 Hz
Sensitivity: >200 μV P-P
CMRR: ≥ 112dB
Differential Input Impedance: >5M
ohm Electrode Offset Potential:±300mV
Polarization Voltage: ≥± 500mV
Input Impedance: ≥ 5 M
Calibration Voltage: 1 mV ± 5%
Power Requirements
AC: 100 ~240V.50Hz/60Hz
DC: Built-in rechargeable battery
Battery: 11.1V 24wh Li-ion Battery
2h operating after full charge
5min operating after low batery alarm
TEMP
Channel 2
Measure & alarm range: 0-50 ºC
Resolution: 0.1ºC
Accuracy (no sensor) : ±0.1ºC (0-50 ºC )
SpO2
Measurement range: 0~100%
Resolution:1%
Accuracy.:70%- 100% ± 2%
40%~ 69% :±3%Pulse Rate
Measure/alarm range: 20~300bpm
Resolution:1bpm
Accuracy :±3bpm
Operating environment:
Temperature: 0~40ºC
Humidity:15%~80%
Pressure :86.0 kPa~106.0 kPa
Transport and Storage environment:
Temperature: -20~55ºC
Humidity:10%~90%
Pressure:86.0 kPa~106.0 kPa
Date Storage
Trend diagram/table: 720h
NIBP review:10000 events
Wave review: 12h
Alarm review:200 alarm events
Suppert drug concentration titration analysis
NIBP
Method:Oscillometry
Measure mode :Manual, Auto. STAT
Measure interval in auto mode:
1~5/10/15/30/60/90/120/180/240/480min
Measure period in STAT mode: 5min
Pulse rate range: 40- 240bpm
Measure & alam range:
Adult
SYS 40~280mmHg
DIA 10 ~220mmHg
MEAN 20 ~240mmHgl
Pediatric
SYS 40 ~220mmHg
DIA 10- 160mmHg
MEAN 20- 170mmHg
Neonatal
SYS 40~135mmHg
DIA 10 ~100mmHg
MEAN 20 ~100mmHg
Range:0~ 300mmHg
Accuracy:±3mmHg
Resolution: 1mmHg Accuracy
Max. Mean Error ± 5mmHg
Max. Standard Deviation: 8mmHg
Overpressure protection:
Adult
300mmHg
Pediatric 240mmHg
Neonatal 150mmHg
SpO2 |
Measurement range: 0~100%
Resolution:1%
Accuracy.:70%- 100% ± 2%
40%~ 69% :±3%Pulse Rate
Measure/alarm range: 20~300bpm
Resolution:1bpm
Accuracy :±3bpm |
NIBP |
Method:Oscillometry Measure mode :Manual, Auto. STAT Measure interval in auto mode: 1~5/10/15/30/60/90/120/180/240/480min Measure period in STAT mode: 5min Pulse rate range: 40- 240bpm Measure & alam range: Adult SYS 40~280mmHg DIA 10 ~220mmHg MEAN 20 ~240mmHgl Pediatric SYS 40 ~220mmHg DIA 10- 160mmHg MEAN 20- 170mmHg Neonatal SYS 40~135mmHg DIA 10 ~100mmHg MEAN 20 ~100mmHg Range:0~ 300mmHg Accuracy:±3mmHg Resolution: 1mmHg Accuracy Max. Mean Error ± 5mmHg Max. Standard Deviation: 8mmHg Overpressure protection: Adult 300mmHg Pediatric 240mmHg Neonatal 150mmHg |