Customization: | Available |
---|---|
Classification: | Physiological Functions of Diagnosis and Monitoring Equipment |
Type: | Patient Monitor |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Standard Configuration | 12.1-inch LED, 3/5 Lead ECG, NIBP, SpO2, Pulse Rate, Temperature, Respiration |
Optional Configuration | 2-Temperature, 1/2 IBP, EtCO2, Imported SpO2, Bed View |
Optional Accessories | Touch Screen, Printer, Central Monitoring Station, Neo/Ped Accessories, Wall-mounting, Trolley |
Dimension and Weight - Dimension: 298mm*272mm*122mm - Weight: 2.5 kg (excluding accessories) Power Supply - Voltage: AC100~240V, 50/60HZ, Power≤60W Display - 12.1" color TFT LED resolution: 800*600 pixels Battery - Type: Rechargeable lithium battery 14.8V/2200mAh - Charge Cycle: ≥500 times - Working time: 3.5 hours Recorder (Option) - Method: Thermal printer - Paper width: 50 mm (1.97 in) - Printing speed: 12.5/25/ 50 mm/s - Trace: Max. 3 tracks - Recording way: Real-time Recording, Review Printing, Periodic Recording, Alarm Recording Alarm - Level: Low, medium and high - Indication: Auditory and visual - Alarm volume adjustable - Alarm pause time: 2min - Parameter alarm type: Latch/ Unlatch Input Device - Standard: Knob /Keypress - Option: Touch screen System Output & Extensible Interface - Ethernet Network: standard RJ45 socket * 1pc - USB Port: 1pc Operating Environment - Temperature: 5 ~ 40 ºC - Humidity: 15% ~ 90% (non-condensing) - Atmosphere pressure: 86 KPa ~ 110 KPa Transportation and Storage - Temperature: -20~50 ºC - Humidity: 10%~90% (non-condensing) - Atmosphere pressure: 86 KPa ~ 110 KPa Safety - IEC60601-1 Approved, CE marking according to MDD93/42/EEC - With reference to RoHS Directive 2011/65/EU recasting Trend & Reviewing - Trend: 720 hours - ARR events: 128 groups of ARR events and associated waveform - NIBP measurement reviewing: 1000 groups - Waveform review: 2 hours - Alarm event: 200 alarms events review SpO2 - Measurement Range: 0 ~ 100 % - Resolution: 1 % - Accuracy: ±2% (70% ~ 100%) Unspecified (0% ~ 69%) - Support Pitch tone and multi-level volume - User-selectable waveform speed: 12.5, 25 mm/s - PI range (Option):0.075%-20% Pulse Rate - Measuring and Alarm Range: 20~250bpm - Accuracy: ±3 bpm - Resolution: 1bpm |
Respiration - Method: Impedance between RA-LL, RA-LA - Gain: ×0.25, ×0.50, ×1, ×2, ×4 - Respiration Rate: Adult 0 ~ 120 BrPM Neonatal / Pediatric 0 ~ 150 BrPM - Sweep speed: 6.25 mm/s, 12.5 mm/s, 25mm/s - Resolution: 1 BrPM - Accuracy: ±2BrPM or ±2% whichever is greater (7~150BrPM) Unspecified (0%~ 6BrPM) - Apnea Alarm: 10 ~ 40 s Temperature - Technique: Thermistor probe (2.25K) - Channel: Dual-channel, provide T1; T2; ΔT - Measuring and Alarm Range: 0.0 ºC~ 50 ºC (32ºF~ 122ºF) - Unit: Celsius (ºC), Fahrenheit ( ºF) - Resolution: 0.1ºCor 1ºF - Accuracy: no sensor ± 0.1ºC(25ºC - 45ºC) ,± 0.2ºC(other) include sensor ± 0.2ºC(32ºC - 42ºC)± 0.3ºC(other) ECG - Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V - Protection: Breakdown Voltage 4000VAC 50/60Hz; Defibrillator proof - Gain: 2.5mm/mV(×0.25), 5.0mm/mV(×0.5), 10mm/mV (×1), 20mm/mV (×2) - Sweep speed: 12.5mm/s, 25mm/s, 50mm/s - ECG signal range: ±5 mV p-p - Accuracy: ±1% - Resolution: 1 bpm - Leakage Current < 10 μA - Baseline Recovery: ≤ 3s after defibrillation - Bandwidth: Surgery 1 ~ 20Hz Monitor 0.5 ~ 40 Hz Diagnostic 0.05 ~ 130 Hz - Indication of Electrode Separation: Every electrode (exclusive of RL) Heart Rate - Measure range: Adult: 15 ~ 300 bpm Neo/Ped: 15 ~ 350 bpm - Resolution: 1 bpm - Accuracy: ± 1% ST Measurement - Range: -2.0 ~ +2.0 mV - Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, whichever is greater, other range: unspecified NIBP - Method: Oscillometric - Measure mode: Manual, Auto, STAT - Measure Interval in AUTO Mode 1,2,3,4,5,10,15,30,60,90,120,180,240,480 min - STAT mode cycle time: 5 minutes - Measure and Alarm Range: Adult: SYS: 40 ~ 280 mmHg DIA: 10 ~ 220 mmHg MEAN: 20 ~ 240 mmHg Pediatric: SYS: 40 ~ 220 mmHg DIA: 10 ~ 160 mmHg MEAN: 20 ~ 170 mmHg Neonate: SYS: 30 ~ 135 mmHg DIA: 10 ~ 110 mmHg |
MEAN: 20 ~ 110 mmHg - Static pressure accuracy: ±3mmHg - Resolution: 1mmHg - Accuracy: Maximum Mean error ±5mmHg Maximum Standard deviation ≤8mmHg - Over pressure Protection: Dual protection EtCO2 (Mainstream/ Sidestream) (Option) - Measure method: Non-dispersive infrared (NDIR) - Measure Range: 0 ~19.7% (0 ~ 150 mmHg) 0 ~ 20 kPa - Resolution: 0.1 mmHg - CO2 Accuracy: 0 ~ 40 mmHg, ±2 mmHg 41 ~ 70 mmHg, ±5% of reading 71 ~ 100 mmHg, ±8% of reading 101~ 150 mmHg, ±10% of reading at 760 mmHg, ambient temperature of 25ºC) - Respiratory Rate: Range: 3 ~150 BrPM Accuracy: ±1 bpm EtCO2 (Micro-stream) (Option) - Measure method: Non-dispersive infrared (NDIR) - Measure Range: 0 ~19.7% (0 ~150 mmHg) 0 ~ 20 kPa - Sample Rate: 50 mL/min ±10mL/min - Resolution: 0.1 mmHg (0 ~ 50 mmHg) 0.25 mmHg (50 ~ 114 mmHg) - CO2 Accuracy: 0 ~ 40 mmHg, ±2 mmHg 41 ~ 70 mmHg, ±5% of reading 71 ~ 100 mmHg, ±8% of reading 101~ 150 mmHg, ±10% of reading at 760 mmHg, ambient temperature of 35ºC) - Respiratory Rate: Range: 3 ~120 BrPM Accuracy: ±1 bpm IBP (Option) - Max Channel: 2 - Measurement way: Thermal resistance way - Press Sensor: Sensitivity 5 uV/V/mmHg, ±2% Impedance 300 to 3000Ω - Resolution: 1 mmHg - Unit: mmKg, kPa, cmH2O - Transducer sites: Arterial Pressure (ART) Pulmonary Arterial (PA) Left Arterial (LAP) Right Arterial (RAP) Central Venous Pressure (CVP) Intracranial Pressure (ICP) P1/ P2 - Measuring and alarm range: ART 0 ~ +350mmHg PA -10 ~ +120 mmHg CVP/ RAP/ LAP/ ICP -10 ~ +40 mmHg P1/ P2 -50 ~ +350mmHg - Accuracy: Static: ±1mmHg or ±2%, whichever is greater (exclusive of transducer) ±4mmHg or ±4%, whichever is greater (inclusive of transducer) Dynamic: ±4mmHg or ±4%, whichever is greater * Specifications subject to change without prior notice |