• FM-V2.6 12.1 Inches Portable Ctg Fetal Heart Doppler Machine
  • FM-V2.6 12.1 Inches Portable Ctg Fetal Heart Doppler Machine
  • FM-V2.6 12.1 Inches Portable Ctg Fetal Heart Doppler Machine
  • FM-V2.6 12.1 Inches Portable Ctg Fetal Heart Doppler Machine
  • FM-V2.6 12.1 Inches Portable Ctg Fetal Heart Doppler Machine
  • FM-V2.6 12.1 Inches Portable Ctg Fetal Heart Doppler Machine

FM-V2.6 12.1 Inches Portable Ctg Fetal Heart Doppler Machine

Product Name: Fetal Monitor
Voltage: AC100-240V, 50/60Hz
Type: Rechargeable Lithium Battery 14.8V/2200mAh
Charge Cycle: 500 Times
Working Time: 2 Hours
Trace: Max 4 Tracks
Samples:
US$ 1440/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Trading Company
  • Overview
  • Product Description
  • Feature
  • Product Parameters
  • Company Profile
Overview

Basic Info.

Model NO.
FM-V2.6
Recording Way
Real-Time Recording, Review Printing
Level
Low, Medium and High
Display
12.1 Inches
Screen
Touch Screen
Transport Package
Paper Box
Trademark
FORERMED
Origin
China
HS Code
8419200000
Production Capacity
20000

Product Description

FM-V2.6 12.1 Inches Portable Ctg Fetal Heart Monitor 

 
 
 
FM-V2.6 12.1 Inches Portable Ctg Fetal Heart Doppler Machine
FM-V2.6 12.1 Inches Portable Ctg Fetal Heart Doppler Machine

Product Description

 


Printer

  • Built-in high-speed thermal printer, printing width can be set to 112mm, 150mm, can meet both US standard and European standard (Brand: SEIKO, Japan)
 
  • Support fast printing of stored trend


Central System
Optional Build-in wireless network module, supporting wired or wireless connection to the central monitoring station.

 

  • Optional Support HL7 (Health Level Seven)

Alarm
  • Three-level acousto-optic alarm
  • FHR signal strength prompt
  • Cross-Channel Verification (CCV) provides visual and audible indication when it detects synchronous fetal or maternal heart rate signals, indicating that you may be monitoring a duplicate signal)
  • Sensor-off alarm
  • Paper out alarm
  • Support alarm review

Linux OS
  • Support operation with mouse and computer keyboard (option)
  • Multi-display mode to meet different clinical requirement, including Fetal-parameter interface, Maternal-parameter interface, Fetal/Maternal-parameter interface, as well as big font, alarm review, ECG review, trend table, trend graph and OxyCRG display.

 

Feature

FM-V2.6 12.1 Inches Portable Ctg Fetal Heart Doppler Machine
  • Newly advanced A9 main board with Linux OS, calculating speed is 4 times faster than traditional products
  • Support storage of 25000 groups of medical record and 8640 hours trend review
  • 12.1 inch Folded high-brightness TFT LED
  • Optional touch screen
  • Humanized probe frame design
  • 12-Crystal ultrasound transducer achieves a wider focal region for more uniform coverage at greater depths than conventional 9-crystal. 12-crystal ultrasound design can also get good result even when the patient varies her position and shape
 
  • Optional waterproof FHR transducer for underwater birth
  • Event Marker for easy documentation of events and kick counts. Auto-fetal-movement detector is also available.
  • Use of signal strength indicator to position the ultrasound transducers at the optimum location on the patient
FM-V2.6 12.1 Inches Portable Ctg Fetal Heart Doppler Machine

 



 
FM-V2.6 12.1 Inches Portable Ctg Fetal Heart Doppler Machine
  • NIBP self-test mode: including overpressure test, static pressure test and air leakage test.
  • On-screen scrolling for viewing stored fetal traces
  • Generate ID automatically when register a new patient
  • Support medical history search by patient ID, name and mobile number
  • NST Timer
  • Fetal Movement Profile (FMP) detects and automatically records gross fetal body movements
  • Heart rate offset mode allowing you to offset FHR2 ± 5~30BPM.
  • Support multi-language display
  • Advanced Fischer NST Report (Fetal Health Report) 
  • Support online software upgrading by net/USB
  • Optional patient data/NST Report backup by USB in PDF format
 

FM-V2.6 12.1 Inches Portable Ctg Fetal Heart Doppler Machine

 

Product Parameters

Performance Specifications
 
Dimension and Weight
 
Dimension
360mm*310mm*120mm
Weight
5.3kg(excluding accessories)
Power Supply
Voltage AC100~240V, 50/60HZ
Display
12.1" color TFT LED (0-90° rotation) Resolution 1024*768 pixels
Battery (Built-in)
Type Rechargeable lithium battery 14.8V/2200mAh
Charge Cycle
≥500 times
Working time
2 hours
Recorder (Built-in)
 
Method
Thermal printer
Paper
Z-fold, thermosensitive
Paper width
112 mm (4.41 in)/150 mm (5.91 in)
Printing speed
1/2/3cm/min
Trace
Max. 4 tracks
-Recording way
Real-time Recording, Review Printing
Alarm
 
Level
Low, medium and high
Indication
Auditory, Visual, Delay of FHR Alarm
Input Device
 
-Touch screen (option)
 
-Knob (Standard)
 
-Keypad input (Standard)
 
Mouse/Keyboard input (option)
 
-USB port for patient data/NST report backup (option)
 
System Output & Extensible Interface
 
-Ethernet Network
1 standard RJ45 socket
-USB Port
2
-Video Output
1 HDMI port (option)
Trend & Reviewing
 
-Cardiotocography (CTG)
 
Waveform Review
8640 hours
-Vital Signs
 
Trend
2160 hours
Waveform Review
2 hours
NIBP Review
2000 groups
-Alarm Review
2000 groups
Safety
 
-IEC60601-1 Approved, CE marking according to MDD93/42/EEC
 
-With reference to RoHS Directive 2011/65/EU recasting
 
-Ultrasound (FHR)
 
-Transducer type
12-Crystal ultrasound transducer
-Measure method
Wide beam pulse doppler
-FHR Measurement range
 
30 to 240 bpm (US Standard)
 
50 to 210 bpm (Europe Standard)
 
Accuracy
±1 bpm
Intensity
<3 mW/cm2
-Ultrasound frequency
1MHz±3%
Resolution
1 bpm
TOCO
 
-Measurement method
Strain gauge sensor element
-Measure range
0 ~ 100 units
Resolution
1 unit
-Nonlinear deviation
≤±8%
-Baseline setting
0,5,10,15, 20 can be selected
-Auto offset correction
3 second after connecting the transducer
-Auto zero adjust
TOCO value is set to zero negative following a negative Measure value for 5 seconds
Fetal Movement Recording
 
-Automatic fetal movement (AFM)
pulsed doppler ultrasound
-Automatic fetal movement autograph
 
-Manual fetal movement marker (MFM)
 
Maternal ECG
 
-Lead mode
3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V
A63Gain
2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV, Auto
Sweep speed
6.25mm/s, 12.5mm/s, 25mm/s, 50 mm/s
Accuracy
±1bpm/ ±1%, whichever is greater
Resolution
1 bpm
Leakage Current < 10 μA
 
CMRR
Diagnostic Mode >89 dB
 
Monitor Mode >105 dB
 
Surgery Mode >105 dB
Bandwidth
Surgery 1 ~ 25 Hz
 
Monitor 0.5 ~ 40 Hz
 
Diagnostic 0.05 ~ 120 Hz
Maternal Heart Rate
 
-Measure range
Adult:0bpm; 10 ~ 300 bpm
 
Neonate:0bpm; 10 ~ 350 bpm
Resolution
1 bpm
Accuracy
± 1% or ± 1bpm, whichever is greater
ST Measurement
 
Range
-2.0 ~ +2.0 mV
Accuracy
-0.8mV~+0.8mV:±0.02mV or ±10%, whichever is greater
-Other range
unspecified
Resolution
0.01mV
Maternal Respiration
 
Method
Impedance between RA-LL, RA-LA
Gain
×0.25, ×0.50, ×1, ×2, ×4
-Respiration Rate
0bpm, 6 ~ 150 bpm
Resolution
1 bpm
Accuracy
±2 bpm or ±2%, whichever is greater
-Apnea Alarm
10 ~ 60 s
Maternal SpO2 (Digital Technic)
 
-Measurement Range
0 ~ 100 %
Resolution
1%
Accuracy
±2% (70% ~ 100%)
±3 % (35% ~ 69%)
 
Unspecified (0 ~ 34%)
 
Pulse Rate
 
Range
25~250bpm
Accuracy
±1% or ±1 bpm, whichever is greater
Resolution
1bpm
Maternal NIBP (MNIBP)
 
Method
Oscillometric
-Measure mode Manual, Auto, STAT
 
-Measure Interval in AUTO Mode 1~480 min
 
-STAT mode cycle time
 
-Keep 5 minutes, at 5 seconds interval
 
-Measure and Alarm Range
 
Systolic
30~270 mmHg
Diastolic
10~220 mmHg
Mean
20~235 mmHg
-Static pressure accuracy ±3mmHg
 
Resolution
1mmHg
Accuracy
Maximum Mean error ±5mmHg
Maximum Standard deviation 8mmHg
 
-Over pressure Protection
Dual protection via software & hardware
Maternal Temperature
 
Technique
Thermistor probe (2.25K)
-Measuring and Alarm Range
0.0 ºC~ 50 ºC (32ºF~ 122ºF)
Unit
Celsius (ºC), Fahrenheit ( ºF)
Resolution
0.1ºC
Accuracy
±0.1ºC
NST Report/FHR Interpretation (Option)
 
-Based on Fischer Evaluation Method (monitoring time≥20 Min)
 
-Average Baseline FHR /Number of Acceleration /Number of Deceleration /Number of Small Acceleration /Amplitude Variation /Number
of PV
 
-Automatic Score Result
Score 8-10 (Excellent)
 
Score5-7 (Suspicious)
 
Score ≤4 ( Fetus Hypoxia)

 

Company Profile


FM-V2.6 12.1 Inches Portable Ctg Fetal Heart Doppler Machine

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now