Customization: | Available |
---|---|
Certification: | ISO, CE |
Brand Name: | Forermed |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Multiple planar ReconstructionAxial, coronal and sagittal slices can be observed simultaneously. Besides, the slice in any
direction is available. Buccolingual slices, distal and mesial sections were obtained to facilitate diagnosis.
Lateral Cephalometric Measurements
In comparison to traditional two-dimensional cephalometric radiographs, lateral cephalograms on CBCT can better reflect the true craniofacial morphology. With higher accuracy in landmark point identification and line distance measurement, it can avoid the distortion of patient measurement data caused by superimposition, image blurring and facial asymmetry of two-dimensional anatomical structures.
Implant Simulation
It can evaluate the bone quality and bone quantity of the implant area, automatically outline the neural tube. Clarifying the
relationship between the implant position and the adjacent anatomical structure to accurately select the implant position, the optimal length and diameter of the implant. It can improve the success rate, and avoid possible nerve or blood vessel damage.
Metal Artifact Correction
With the new T-MAR correction module for metal artifact removal, the system corrects metal artifacts intelligently. It avoids
overmodification and saves the original clinical data.
3D Fine Reconstruction
The smallest voxel size reaches 0.05 mm, which is more suitable for the diagnosis of dental pulp disease.
Density Measurement
Visual assessment of bone quality, bringing greater convenience to dentists.
Image Slice for Implanting
It permits the evaluation of the overall osteogenesis and facilitates the macroscopic observation of the bone condition around implants.
System
- A perfect partner for dental offces
|
Model
|
3D-Plus
|
3D-Max
|
|
Field of View(mm*mm)
|
170*170160*100
160*50 80*80 |
200*170160*100
160*50 80*80 |
230*180160*100
160*50 80*80 |
Voxel Size(mm)
|
0.30.25/0.125
0.2/0.1 0.125/0.0625 |
0.30.25/0.125
0.2/0.1 0.125/0.0625 |
0.3/0.150.25/0.125
0.2/0.1 0.125/0.0625 |
Spatial Resolution
|
2.4 lp/mm
|
2.2 lp/mm
|
|
Reconstruction Time
|
≤40s
|
≤40s
|
|
Tube Current
|
Min:2 mA Max: 10mA
|
||
Tube Voltage
|
Min: 60KV Max: 100KV
|
||
Scan Time
|
25/12.5/15.625/18.75s
|
12.5/12.5/15.625/18.75s
|
|
Focal Spot Size
|
0.5(IEC60336)
|
||
Sensor type
|
α-Si Flat panel detector
|
||
Sensor Size
|
16*16cm
|
26*21cm
|
|
Unit Dimensions
|
1825*1077*2109mm
|
||
Weight
|
340kg
|
||
Packing Size
|
Case1: 1930*800*1300mm 304KGCase2: 1970*1270*1170mm 290KG
|
||
Power
|
Single-phase, AC220V/230V, ±10%, 10A, 50Hz/60Hz,±1Hz
|