Customization: | Available |
---|---|
Product Name: | Patient Monitor |
Display: | 12.1′′ Real Color TFT Screen |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Display * 12.1"real color TFT Screen Enviroment Operating environment: Temperature: 0~40ºC Humidity:15%~80% Pressure :86.0 kPa~106.0 kPa Transport and Storage environment: Temperature: -20~55ºC Humidity:10%~90% Pressure:86.0 kPa~106.0 kPa Power Requirements AC: 100 ~240V.50Hz/60Hz DC: Built-in rechargeable battery Battery: 11.1V 24wh Li-ion Battery 2h operating after full charge 5min operating after low battery alarm Dimension and Weight * Equipment: 340mm x 245mm x134 mm(about); 2.798kg(about) * Package: 380mm x350 mm x 300mm; 4.598 kg(about) Application Range Adult/Pediatric/Neonatal/Medicines/ Surgery Operating Room/ICU/CCU |
Date Storage Trend diagram/table: 720h NIBP review:10000 events Wave review: 12h Alarm review:200 alarm events Suppert drug concentration titration analysis ECG 5 Leads: RA, LA, LL RL, V Lead mode: I, m., AVR, AVL, AVF.V Gain: x 1.25 mm/mV, 2.5 mm/mV. 5.0 mm/mV, 10 mm/mV, 20mm/mV (error ≤ 5%) Sweep speed: 6.25mm/s. 12.5mm/s,25mm/s,50mm/s (error ≤ ± 10%) Bandwidth: Surgery 1~25 Hz Monitor 0.5~40 Hz Diagnostic 0.05-130 Hz Sensitivity: >200 μV P-P CMRR: ≥ 112dB Differential Input Impedance: >5M ohm Electrode Offset Potential:±300mV Polarization Voltage: ≥± 500mV Input Impedance: ≥ 5 M Calibration Voltage: 1 mV ± 5% ST Segment ST Segment Range: -2.0 mV ~ + 2.0 mV Accuracy:0.02 mV |
NIBP Method: Oscillometry Measure mode: Manual, Auto. STAT Measure interval in auto mode: 1~5/10/15/30/60/90/120/180/240/480min Measure period in STAT mode: 5min Pulse rate range: 40- 240bpm * Measure & alam range: -Adult SYS 40~280mmHg DIA 10 ~220mmHg MEAN 20 ~240mmHgl -Pediatric SYS 40 ~220mmHg DIA 10- 160mmHg MEAN 20- 170mmHg -Neonatal SYS 40~135mmHg DIA 10 ~100mmHg MEAN 20 ~100mmHg * Static pressure measurement Range:0~ 300mmHg Accuracy:±3mmHg Resolution: 1mmHg Accuracy Max. Mean Error ± 5mmHg Max. Standard Deviation: 8mmHg Overpressure protection: Adult 300mmHg Pediatric 240mmHg Neonatal 150mmHg SpO2 Measurement range: 0~100% Resolution:1% Accuracy.:70%- 100% ± 2% 40%~ 69% :±3% |
Pulse Rate Measure/alarm range: 20~300bpm Resolution:1bpm Accuracy :±3bpm RESP Method: impedance between RA-LL Resp Impedance range: 0.3-3Ω Base Impedance range: 200 Ω-4000 Ω Bandwidth : 0.3 ~2.5Hz Gain: x 0.25, x0.5, x1,x2 x4 Resp rate: Measurement Range -Adult 0 ~ 120BrPM -Neonatal/Pediatric 0~150BrPM Resoluition: 1 BrPM Accuray: 7~ 150BrPM ( ±2BrPM); 0 ~ 6BrPM(unspecified) Apnea Alarm: 10- 40s TEMP Channel 2 Measure & alarm range: 0-50 ºC Resolution: 0.1ºC Accuracy (no sensor) : ±0.1ºC (0-50 ºC ) Standard accessories NIBP cuff & tube ECG cable & electrodes SpO2 sensor TEMP probe Lithium-ion battery Power cable Operator's manual Optional accessories IBP CO2 SpO2 |
Standard accessories
|
NIBP cuft & tube
|
ECG cable & electrodes
|
|
SpO2 sensor
|
|
TEMP probe
|
|
Lithium-ion battery
|
|
Power cable
|
|
Operator's manual
|
|
Optional accessories
|
IBP
|
CO2
|
|
SpO2
|