CTG machine Maternal Fetal Monitor for Pregnant Women
Performance Specifications
|
|
Dimension and Weight
|
- Dimension: 360mm*310mm*120mm - Weight: 5.3kg(excluding accessories) |
Power Supply
|
- Voltage: AC100~240V, 50/60HZ
|
Display
|
- 12.1" color TFT LED (0-90° rotation) - Resolution: 1024*768 pixels |
Battery (Built-in)
|
- Type: Rechargeable lithium battery 14.8V/2200mAh - Charge Cycle: ≥500 times - Working time: 2 hours |
Recorder (Built-in)
|
- Method: Thermal printer - Paper: Z-fold, thermosensitive - Paper width: 112 mm (4.41 in)/150 mm (5.91 in) - Printing speed: 1/2/3cm/min - Trace: Max. 4 tracks - Recording way: Real-time Recording, Review Printing |
Alarm
|
- Level: Low, medium and high - Indication: Auditory, Visual, Delay of FHR Alarm |
Input Device
|
- Touch screen (option) - Knob (Standard) - Keypad input (Standard) - Mouse/ Keyboard input (option) - USB port for patient data/NST report backup(option) |
System Output &Extensible Interface
|
- Ethernet Network: 1 standard RJ45 socket - USB Port: 2 - Video Output: 1 HDMI port (option) |
Trend & Reviewing
|
- Cardiotocography (CTG): Waveform Review: 8640 hours - Vital Signs: Trend: 2160 hours Waveform Review: 2 hours NIBP Review: 2000 groups - Alarm Review: 2000 groups |
Safety
|
- IEC60601-1 Approved, CE marking according to MDD93/42/EEC - With reference to RoHS Directive 2011/65/EU recasting |
Ultrasound (FHR)
|
- Transducer type: 12-Crystal ultrasound transducer - Measure method: Wide beam pulse doppler - FHR Measurement range: 30 to 240 bpm (US Standard) 50 to 210 bpm (Europe Standard) - Accuracy: ±1 bpm - Intensity: <3 mW/cm2 - Ultrasound frequency: 1MHz±3% - Resolution: 1 bpm |
TOCO
|
- Measurement method: Strain gauge sensor element - Measure range: 0 ~ 100 units - Resolution: 1 unit - Nonlinear deviation : ≤±8% - Baseline setting: 0,5,10,15, 20 can be selected - Auto offset correction: 3 second after connecting the transducer - Auto zero adjust: TOCO value is set to zero negative following a negative Measure value for 5 seconds |
Fetal Movement Recording
|
- Automatic fetal movement (AFM): pulsed doppler ultrasound - Automatic fetal movement autograph - Manual fetal movement marker (MFM) |
Maternal ECG
|
- Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V - Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV, Auto - Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50 mm/s - Accuracy: ±1bpm/ ±1%, whichever is greater - Resolution: 1 bpm - Leakage Current < 10 μA - CMRR: Diagnostic Mode >89 dB Monitor Mode >105 dB Surgery Mode >105 dB - Bandwidth: Surgery 1 ~ 25 Hz Monitor 0.5 ~ 40 Hz Diagnostic 0.05 ~ 120 Hz |
Maternal Heart Rate
|
- Measure range: Adult: 0bpm; 10 ~ 300 bpm Neonate: 0bpm; 10 ~ 350 bpm - Resolution: 1 bpm - Accuracy: ± 1% or ± 1bpm, whichever is greater |
ST Measurement
|
- Range: -2.0 ~ +2.0 mV - Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, whichever is greater - Other range: unspecified
- Resolution: 0.01mV
|
Maternal Respiration
|
- Method: Impedance between RA-LL, RA-LA - Gain: ×0.25, ×0.50, ×1, ×2, ×4 - Respiration Rate: 0bpm, 6 ~ 150 bpm - Resolution: 1 bpm - Accuracy: ±2 bpm or ±2%, whichever is greater - Apnea Alarm: 10 ~ 60 s |
Maternal SpO2 (Digital Technic)
|
- Measurement Range: 0 ~ 100 % - Resolution: 1 % - Accuracy: ±2% (70% ~ 100%) ±3 % (35% ~ 69%) Unspecified (0 ~ 34%) |
Pulse Rate
|
- Range: 25~250bpm - Accuracy: ±1% or ±1 bpm, whichever is greater - Resolution: 1bpm |
Maternal NIBP (MNIBP)
|
- Method: Oscillometric - Measure mode Manual, Auto, STAT - Measure Interval in AUTO Mode 1~480 min - STAT mode cycle time: - Keep 5 minutes, at 5 seconds interval - Measure and Alarm Range: Systolic: 30~270 mmHg Diastolic: 10~220 mmHg Mean: 20~235 mmHg - Static pressure accuracy ±3mmHg - Resolution: 1mmHg - Accuracy: Maximum Mean error ±5mmHg Maximum Standard deviation 8mmHg - Over pressure Protection: Dual protection via software & hardware |
Maternal Temperature
|
- Technique: Thermistor probe (2.25K) - Measuring and Alarm Range: 0.0 ºC~ 50 ºC (32ºF~ 122ºF) - Unit: Celsius (ºC), Fahrenheit ( ºF) - Resolution: 0.1ºC - Accuracy: ±0.1ºC |
12.1 inches Fetal Monitor Model
|
Config. A
|
Config. B
|
Config. C
|
Config. D
|
|
Fetal Parameter
|
Single FHR
|
*
|
*
|
*
|
*
|
Dual FHR
|
N/A
|
*
|
N/A
|
*
|
|
TOCO
|
*
|
*
|
*
|
*
|
|
AFM & MFM
|
*
|
*
|
*
|
*
|
|
Signal Overlap Alarm
|
N/A
|
*
|
*
|
*
|
|
Maternal Parameter
|
NIBP, SpO2, PR
|
N/A
|
N/A
|
*
|
*
|
ECG, TEMP, RESP
|
N/A
|
N/A
|
*
|
*
|
|
Printer Paper Width
|
112mm A type
|
Opt
|
Opt
|
Opt
|
Opt
|
112mm B type
|
Opt
|
Opt
|
Opt
|
Opt
|
|
150mm A type
|
Opt
|
Opt
|
Opt
|
Opt
|
|
150mm B type
|
Opt
|
Opt
|
Opt
|
Opt
|
|
Battery
|
Lithium battery
|
*
|
*
|
*
|
*
|
Option:
|
1) HDMI
|
||||
2) Touch Screen
|
|||||
3) Fetal Stimulator
|
|||||
4) Wall-mount
|
|||||
5) Trolley
|
|||||
6) Waterproof FHR Probe & TOCO Probe
|
|||||
7) Central Monitoring Station
|
|||||
8) Keyboard & Mouse control function
|
|||||
9) Advanced Fischer NST Report
|
|||||
10) USB port with patient data/NST report backup function
|
|
||||
Remark: The touch screen and mouse/ computer keyboard is not compatible by now.
|
|||||
Table legend: : Standard , N/A - not applicable
|
1.FHR Transducer
2.TOCO Transducer
3.Event Marker
4.Fetal Acoustic Stimulator
5.Central Monitoring Station
6.Reusable Transducer Belt
7.NIBP Cuff and NIBP Tube
8.SpO2 Transducer
9.Temperature Transducer (Skin / Rectal type)
10.ECG Cables
11.Wall-mount with basket
12.Trolley with Basket
13.112(A) mm Thermal Paper (112mm×100mm×150p,European Standard, 30-210 bpm)
14.112(B) mm Thermal Paper (112mm×100mm×150p, USA
Standard, 30-240 bpm
15.150 (A) mm Thermal Paper (150mm×100mm×150p, European Standard, 50-210bpm)
16.150 (B) mm Thermal Paper (150mm×100mm×150p, USA Standard, 30-240bpm)
1).Does your product has any certificate?
Almost all our medical equipment is CE, ISO approved.
2).What's your payment terms?
We can accept T/T,Western Union, Money Gram, Paypal, Alibaba Trade Assurance, L/C,cash etc
3).What's your product lead time?
Normally all our medical equipment are in stock, so we can deliver goods within 3 workdays after receipt payment.
4).How to maintenance the product if it has problem?
We have professional engineers,they will solve your problem by communicating with skype or phone. If the machine is totally broken and can not work, send it back to us and we will send a new one to you.
5).What's your shipping terms?
Foermed offers courier,air,sea shipping methods.Client can choose anyone depends on detail situation.