Customization: | Available |
---|---|
Certification: | CE, ISO13485 |
Type of Body Fluid-Processing Device: | Human Blood Processor |
Still deciding? Get samples of US$ 16000/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
YJ-5000 hemodialysis machine
Product parameters
|
|
Basic Information
|
|
Dimension
|
Height 1720 mm/Width 635 mm/Thickness 578 mm
|
Weight
|
About 75Kg
|
Electrical Parameters
|
|
Voltage
|
-110/220V
|
Frequency
|
50/60Hz
|
Power
|
500VA
|
Backup Battery Capacity
|
2×12V/4Ah
|
Pressure Monitoring
|
|
Venous Pressure Monitoring(Vp)
|
-500mmHg~+700mmHg Accuracy:±5mmHg |
Arterial Pressure Monitoring(Ap)
|
-500mmHg~+700mmHg Accuracy:±5mmHg |
Transmembrane Pressure Monitoring(Tmp)
|
-500mmHg~+700mmHg Accuracy:±5mmHg |
Primary Membrane External Pressure Monitoring(Pm1)
|
Accuracy:±5mmHg -500mmHg~+700mmHg |
Secondary Membrane Pressure Monitoring(Pm2)
|
-500mmHg~+700mmHg Accuracy:±5mmHg |
Liquid Balance Control
|
|
ScaleNumber
|
4
|
Rehydration Scale
|
Accuracy;±5gor ±0.1% Okg~30kg |
Waste Liquid Scale
|
Okg~30kg Accuracy:±5gor ±0.1% |
Auxiliary Rehydration Scalel
|
Okg~12kg Accuracy;±5gor±0.1% |
Flow Monitoring
|
|
Blood pump flow(BP)
|
0mL/min,30mL/min~600mL/min Accuracy: set value±10% |
LP1
|
0mL/min,1ml/min~250ml/min Accuracy:±0.1mL/min or±5% ofsetvalue |
Waste Liquid Pump Flow(UFP) |
0mL/min,1mL/min~250mL/min Accuracy:±0.1mL/min or±5% ofsetvalue |
LP2
|
0mL/min,1mL/min ~250mL/min Accuracy:±0.1mL/min or±5% ofsetvalue |
Function Pump Flow(FP) |
0mL/min,1mL/min~250mL/min Accuracy:±0.1mL/minor±5% ofsetvalue |
Infusion pump flow
|
|
Flow Adjustable Range
|
0mL/h~10mL/h
|
Error Range
|
0.2mL/hor±5%
|
Rapid Injection Flow
|
10mL/h~2000mL/h
|
Syringe Specification
|
10mL/20mL/30mL/50ml
|
Dehydration Error
|
<±20mL/h
|
Liquid Balance Control
|
100ml
|
Substitution fluid flow temperature control
|
|
Control Range
|
33ºC~ 40ºC
|
Accuracy
|
Control error ±1° C
|
Safety Monitoring
|
|
Blood Leakage Monitoring |
≤ 0.35mL/min(HCT 32%)
|
Air Monitoring
|
>0.02mL bubbles
|
Note: The above parameters are YJ-5000 series, Specific parameters are subject to the operating manual.
|
Each Model Treatment Mode Contrast
|
||||
Treatment Mode
|
YJ-5000 (full function) |
YJ-5000 (professional) |
YJ-5000A
|
YJ-5000B
|
Citriate anticoagulation
|
√
|
√
|
√
|
X
|
Substitution Fluid Double Channel Input
|
√
|
√
|
√
|
X
|
CVVH- Continuous Veno-Venous Hemofiltration
|
√
|
√
|
√
|
√
|
CVVHD-Continuous Veno-Venous Hemodialysis
|
√
|
√
|
√
|
√
|
CVVHDF-ContinuousVeno-Venous Hemodiafiltration
|
√
|
√
|
√
|
X
|
SCUF-Slow Continuous Ultrafiltration
|
√
|
√
|
√
|
√
|
HP- Hemoperfusion
|
√
|
√
|
√
|
√
|
PE-Plasma Exchange
|
√
|
√
|
√
|
√
|
PA- PlasmaAdsorption
|
√
|
√
|
√
|
√
|
CPFA-Continuous Plasma Filtration And Adsorption
|
√
|
√
|
O
|
X
|
FPSA-Fractional Plasma Separation And Absorption
|
√
|
O
|
O
|
X
|
MARS-Molecular Absorbent Recycling System
|
√
|
O
|
O
|
X
|
SPAD -Single PassAlbumin Dialysis
|
√
|
O
|
O
|
X
|
DFPP-Double Filtration Plasmapheresis
|
√
|
O
|
O
|
X
|
RAD -Repeated Pass Albumin Dialysis
|
√
|
O
|
O
|
X
|
PDF- Plasmadiafiltration
|
√
|
O
|
O
|
X
|
Note: O means optional
|
Quantity(Units) | 1 - 10 | >10 |
Est. Time(days) | 3 | To be negotiated |