Customization: | Available |
---|---|
Classification: | Imaging Diagnostic Equipment |
Type: | X Ray Equipment |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
YJ-PLX7000B C-arm digital fluoroscopy machine
Parameters
1. High frequency generator
1.1 Output power: 6kW
1.2 Inverter frequency: 60kHz
2. X-ray tube
2.1 For high frequency special use
2.2 Tube anode: rotating type
2.3 Tube focus: dual, 0.3mm/0.6mm
2.4 Anode heat capacity: 212kJ (300kHu)
2.5 Thermal heat capacity: Max. 1000kJ (1300kHu)
3. Continuous fluoroscopy (manual &auto)
3.1 Tube voltage: 40kV-125kV, continuous adjustable
3.2 Tube current: 0.3mA~4mA, continuous adjustable
4. Enhance fluoroscopy (manual & auto)
4.1 Tube voltage: 40kV-125kV, continuous adjustable
4.2 Tube current: 0.3mA~8mA, continuous adjustable
5. Photography mode
5.1 Tube voltage: 40-125kV, continuous adjustable
5.2 Tube current: 25-120mA
5.3 mAs range: 0.1mAs~280mAs
YJ-PLX7000B
Parameters
1. High frequency generator
1.1 Output power:12kW
1.2 Inverter frequency: 60kHz
2. X-ray tube
2.1 For high frequency special use
2.2 Tube anode: rotating type
2.3 Tube focus: dual, 0.3mm/0.6mm
2.4 Anode heat capacity: 212kJ (300kHu)
2.5 Thermal heat capacity: Max. 1000kJ (1300kHu)
3. Continuous fluoroscopy (manual &auto)
3.1 Tube voltage: 40kV-125kV, continuous adjustable
3.2 Tube current: 0.3mA~4mA, continuous adjustable
4. Enhance fluoroscopy (manual & auto)
4.1 Tube voltage: 40kV-125kV, continuous adjustable
4.2 Tube current: 0.3mA~8mA, continuous adjustable
5. Pulse fluoroscopy (manual & auto)
5.1 Tube voltage: 40kV-125kV, continuous adjustable
5.2 Tube current: 0.3mA~30mA, continuous adjustable
5.3 Pulse frequency: intelligent control
5.4 DSI spot film function
6. Photography mode
6.1 Tube voltage: 40-125kV, continuous adjustable
6.2 Tube current: 160mA
6.3 mAs range: 0.1mAs~320mAs
YJ-PLX7000B
Parameters
I. Technical Specifications
1. High frequency generator
1.1 Output power:16kW
1.2 Inverter frequency: 60kHz
2. X-ray tube
2.1 For high frequency special use
2.2 Tube anode: rotating type
2.3 Tube focus: dual, 0.3mm/0.6mm
2.4 Anode heat capacity: 212kJ (300kHu)
2.5 Thermal heat capacity: Max. 1000kJ (1300kHu)
3. Continuous fluoroscopy (manual &auto)
3.1 Tube voltage: 40kV-125kV, continuous adjustable
3.2 Tube current: 0.3mA~4mA, continuous adjustable
4. Enhance fluoroscopy (manual & auto)
4.1 Tube voltage: 40kV-125kV, continuous adjustable
4.2 Tube current: 0.3mA~8mA, continuous adjustable
5. Pulse fluoroscopy (manual & auto)
5.1 Tube voltage: 40kV-125kV, continuous adjustable
5.2 Tube current: 0.3mA~30mA, continuous adjustable
5.3 Pulse frequency: intelligent control
5.4 DSI spot film function
6. Photography mode
6.1 Tube voltage: 40-125kV, continuous adjustable
6.2 Tube current: 200mA
6.3 mAs range: 0.1mAs~320mAs