Customization: | Available |
---|---|
Theory: | Plasma Sterilizer |
Type: | Gas Sterilization Equipments |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
YJ-PVS130
|
Model
|
YJ-PVS60
|
1060(L)*860(W)*1660(H)
|
External Dimensions
|
940(L)*650(W)*1510(H)
|
432(L)*790(W)*420(H)
|
Chamber Dimensions
|
320(L)*652(W)*330(H)
|
350kg
|
Weight
|
405kg
|
130Liter
|
Chamber Capacity
|
60Liter
|
Touch screen(7'' LCD)
|
Control Interface
|
Touch screen (7'' LCD)
|
5ºC~40ºC
|
Extemal Temperatures
|
5ºC~40ºC
|
30%~80%
|
Humidity
|
30%~80%
|
AC220V/50Hz
|
Rated input
|
AC220V/50Hz
|
3.6kw
|
Rated power
|
2.5kw
|
40ºC~55ºC
|
Intemal Temperatures
|
40ºC~55ºC
|
30~60min
|
Cycle Period
|
20~60min
|
Operation method
|
LCD touch screen touch operation
|
Sterilization method |
1. Hydrogen peroxide plasma technology,
2. No residual hydrogen peroxide, no environmental impact technology, working environment meets national standards. 3. Automatic detection of H2O2 injection system, which can automatically detect the volume of sterilized items and release unequal amounts of H2O2. |
Disinfectant |
1. 50% hydrogen peroxide solution;
2. The independent bottle type operation is more convenient, and the human body has no contact; 3. The amount of hydrogen peroxide in each mode is about 10ml |
Sterilization speed |
1 standard sterilization ≤35 minutes;
2. Surface sterilization can be shortened to 26 minutes. 3. Full load sterilization time ≤ 60 minutes. |
Sterilization mode |
1. Multi-program selection: standard sterilization, surface sterilization, preheat sterilization, advanced sterilization
2. Countdown display 3. Display of sterilization status in mode |
Sterilization
temperature |
50 ºC ± 5 ºC, the program will automatically terminate when sterilization is
over temperature |
Sterilization effect |
The sterilization program can effectively sterilize stainless steel tubes with a diameter of 1mm and a length of 500mm and PTFE
tubes with a diameter of 1mm and a length of 2000mm. |
Main control system |
1. Imported embedded microcomputer control, with 7-inch original imported resistive touch screen LCD (color interface) operating
system; 2. Parameters such as sterilization time are different for different modes; |
Sterilization records |
1. The pressure, time, cycle mode, process stage, etc. of the sterilization process are automatically displayed on the touch
screen, and the working process is automatically printed. |
|
2. Automatic storage and retrieving system for printed information. The sterilizer can obtain sterilization information by
inserting a USB storage device. The storage content: number, date, sterilization mode, and sterilization process information. The sterilization record can be stored not less than 5000 Times. Information such as pressure and temperature can be recorded and stored every second during sterilization. 3. The computer records all sterilization processes of the user, including the sterilization mode. |
Alarm system |
1. Automatic alarm system, and touch screen text to display alarm content. With over-humidity fault alarm, hydrogen peroxide
supply fault alarm, sterilization chamber temperature abnormal alarm, injection heater temperature abnormal alarm, sterilization door fault alarm |
2. Sterilization pressure and temperature with alarm settings.
|
|
3. Maintenance alarm prompts for key components such as vacuum pump oil change.
|
|
Sterilization room door |
1. LCD screen touch, automatic door opening and closing, photoelectric anti-pinch hand design; electric lifting door, equipped
with a safety system on the door to ensure equipment and personal safety, anti-pinch hand design, foot sensor switch 2. The material of the cavity is stainless steel 304, the thickness is ≥8mm, and the material of the sealing door is high-quality aluminum, the thickness is ≥18mm. |
Vacuum pump
|
The vacuum pump has low noise, low emissions, fast evacuation, high stability, low
maintenance costs, and an evacuation rate of 18 liters / second |
Sterilization residue
|
Non-toxic
|
Vacuum pump oil replacement time
|
Use in a clean air environment, change every 180 days
|
Impact on medical staff
|
The ultraviolet rays generated by the plasma are completely shielded from the operator and completely invisible to the naked eye.
|
Fully equipped with supplies
|
Plasma special chemical instruction card, chemical instruction label, packaging bag, sterilant, self-contained biological
indicator. |
Power Supply
|
AC220V,50Hz,3.6KW
|
The key components
|
Vacuum pump, pressure transmitter, solenoid valve, air filter, embedded microcomputer, temperature controller, relay, etc.
|
Work environment
|
Install and make use of it at indoor
Ø Temperature: 5ºC~40ºC Ø Humidity : 30%~80% Mains voltage fluctuation:110V±10% Altitude is at most 2000m Transient overvoltage category: Ø Rated pollution degree: 2 |