Customization: | Available |
---|---|
Classification: | Anesthesia & Ventilator |
Type: | Anesthesia & Ventilator |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
YJ-560 Portable Anesthesia Machine
YJ-560 anesthesia machine is an economic type of anesthesia machine.
The high-precision Vaporizer is designed with a stable concentration output,automatic compensation for pressure, temperature and flow rate.
And it is available to choose one kind of gas from Halothane, Enflurane, Isoflurane, and Sevoflurane, ensuring a successful anesthesia operation.
Reliable pneumatic transmission system Economic and proper configuration of technologies, optional as required by the Customer.
Modularized design and upgrading.Upgrading is available as required by the Customer.
Part of Anesthesia Machine: | |
Main body | high-strength engineering plastic rack,light, beautiful and corrosion resistance |
Scope of application | 2 kg above animal |
Gas Source | O2, N2O: 0.28~0.6MPa |
Flow meter | O2:0.05~1.0L/min 1.1~10L/min (O2:0.05~10L/min N2O:0.05~10L/min) (O2,N2O linkage and N2O Stopper) (When using nitrous oxide, oxygen concentration≥25%;When the oxygen pressure < 0.2Mpa,the flow of nitrous oxide would be cut off ) |
Flow rate of rapid oxygen supply | 25~75L/min |
Low oxygen pressure alarm | it will be alarmed when the oxygen pressure < 0.2MPa |
Vaporizer | it has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0 ~ 5vol%. Among Halothane, Enflurane,, Isoflurane and Sevoflurane, one can be chosen for application as required by the customer |
Respiratory circuit | work mode :all close, semi-close. semi-open APL:≤12.5kPa |
Respiratory Bellows | bellows for adults,bellows for children tidal volume range:0~1500ml |
Part of ventilator | |
Display mode | High-definition 5.7" LCD screen display |
Ventilator mode | PPV, SIPPV, SIMV, MANUAL (Manual monitoring of tidal volume, ventilation volume, respiratory rate) |
Ventilator function | PEEP, SIGH, IRV |
Ventilator parameter: | |
Tidal volume | 50~1500ml |
Rate | 2~99bpm |
SIMV rate | 2-20bpm |
I:E | 2:1~1:8 |
Inspiratory trigger pressure | -10~20cmH2O |
PEEP | 2~20 cmH2O |
Pressure limit | 10~60 cmH2O |
SIGH | 1.5 times the inspiratory time/100bpm |
Parameters for ventilation monitoring | Tidal volume. Minute Ventilation volume. IPPV rate. SIMV rate. total respiratory rate. I/E. peak pressure of airway . pressure - time waveform. flow rate - time waveform. PEEP. inspiratory trigger pressure,( average pressure, oxygen concentration, battery capacity) |
Security Alarm System | |
Oxygen Concentration alarm | upper limit setting range (21%~99%) low limit setting range (18%~80%) |
Airway pressure alarm | upper limit setting range 5~60 cmH2O low limit setting range |
Minute ventilation volume alarm | upper limit setting range 1~20 L/min low limit setting range 0~19 L/min |
Tidtal volume | upper limit setting range 10~1500ml low limit setting range 0~1400ml |
Sustained high-pressure alarm | it will give alarm when stress have consistently been higher than 25 cmH2O |
(Suffocation alarm, Power alarm, Intubation off alarm, battery voltage alarm) | |
Power | AC 220V 50Hz |
ICU Equipment | Lab equipment | Medical image | Medical Cold Chain |
anesthesia machine | Biochemistry Analyzer | Ultrasound system | BBR |
Medical ventilator | Hematology analyzer | X-ray | Deep freezer |