Customization: | Available |
---|---|
Type: | Veterinary X Machine |
Product Name: | Veterinary X Ray Machine |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
No | Item | Quantity |
1 | Veterinary use 32KW High Power Generator | 1 unit |
2 | XRayTube | 1 unit |
3 | Beam Aligner | 1 unit |
4 | Metal Imaging Bed | 1 sheet |
5 | Flat Panel Detector | 1 pair |
6 | Desktop Computer set | 1 set |
7 | 15.6 touchable screen | 1 piece |
8 | Vet Software | 1 set |
9 | Lead Coat (Three-pieces) | 2 set |
10 | Vet Position assistor | 2 pieces |
11 | Cables and other accessories |
Product Parameters: | ||
No | Parameters | |
1 | X Ray High Power Generator | |
1.1 | Power Supply Voltage: Single-phase 3-wire power cable 220V±22V | |
1.2 | Supply Frequency 5OHz ±1Hz | |
1.3 | Rated Power : 32Kw | |
1.4 | Max Output Current :400mA | |
1.5 | Operating frequency 300Hz | |
1.6 | Current regulation range :lOmA'""'--'400mA | |
1.7 | Tube voltage regulation range: (RAD)40-150kV, (Fluoro)40-110kV | |
1.8 | Exposure time range ; O.OOls'""'-'10.0s for imaging mode, 15minutes for dynamic mode | |
1.9 | Current time product range: O.lmAs-----320mAs | |
2 | Canon 72 40 X Ra y Tube | |
2.1 | Maximum peak voltage 125kv | |
2.2 | Spot Focus :Smallspot focus :0.6mm ,large spot focus :1.mm | |
2.3 | manode input power: 20kw for small sport focus/40kw for large spot focus | |
2.4 | Anode Speed : 2700rpm | |
2.5 | Target Angle 14° | |
2.6 | Anode heat capacity :200KHU | |
3 | Beam Al i g n e r | |
3.1 | Control method: Manual | |
3.2 | Radiation field Omm*Omm-430mm*430mm | |
3.3 | Power Supply :12V-24V | |
3.4 | light duration 30±5s | |
3.5 | inherentfiltration75kV: ?:1.0mmAI | |
3.6 | Weight: 6kg±0.5 | |
4 | Metal Imaging Bed (fixed straight arm +floatingtable ) | |
4.1 | Table size : LXW 1510mmx635mm | |
4.2 | Total Height :1960mm | |
4.3 | Rotation angle: Perpendicular 90 to the right | |
4.4 | Floating Max size (Front to Behind):180mm Floating Maxsize (Left to Right) :240mm | |
5 | Iray 1717Z Flat Panel Detector | |
5.1 | Scintillator: Csl: TI | |
5.2 | Imaging region :430 x 430 mm2 | |
5.3 | Pixel array :3072 x 3072 | |
5.4 | Pixel size :139µm | |
5.5 | A/Dconversion : 16bits | |
5.6 | Energy range :50kV-11 OkV | |
5.7 | Date interface :GigE | |
5.8 | Trigger Mode :Syncin/Syncout | |
5.9 | Binning :1x1 /2x2/3x3 | |
5.10 | Sensitivity (ADC/nGy): > 15@PGA3 (1.2pC) Binning 3x3 > 0.85@PGA6{7.2pC)Binning lxl | |
5.11 | Dynamic range :>77dB@PGA6 1x1 | |
5.12 | MTF@RQAS: 55%@1.0LP/mm 30%@2.0LP/mm 14%@3.0LP/mm | |
6 | Veterinary Software | |
6.1 | Interface: 16languages supported ,work-list supported | |
6.2 | Capture patient images through DlCOM Worklist) BDT/GDT) HL7 or other protocol data can also be manually acquired; | |
6.3 | Infinite zoom,(measurement)lens, rotation, mirroring, etc.; | |
6.4 | Quick and secure registration of emergency patients, and quick access to patient or research data;, | |
6.5 | Archive all research results and preserve search preferences; |