12.1"real color TFT Screen Multi-parameter Patient Monitor
YJ-C800 patient monitor is designed to match the pace and unique needs of adult, pediatric, and neonatal intensive care; anesthesia and peri-operative care; OR and cardiac care environments. Pacemaker detection and Arrhythmia analysis.
Display
12.1"real color TFT Screen
Built-in Recorder & WEAN modular (option)
3-Channel thermal recorder offers convenient documentation
Wifi wireless connectivity realizes in hospital transportation
Dual Alarm Light
Physiological Alarm Light & Equipment Technical Alarm LightExtra Large Alarm Light Design
All-in-one
ECG,RESP,SpO2,NIRP,2-TEMP(Standnrd)
9-lends ECG,2-IBP, Cardio Output(ICG) Side stream/mainstream/
Micro strenm CO2
Various Extensible interfaces
Standard: Ethernet Network, Defibrillation Synchronization Output, Nurse Call
Option: analog output, USB Port, VGA output
ECG
- 5 Leads: RA, LA, LL RL, V
- Gain: x 1.25 mm/mV, 2.5 mm/mV.
5.0 mm/mV, 10 mm/mV, 20mm/mV (error ≤ 5%)
Sweep speed: 6.25mm/s.
12.5mm/s,25mm/s,50mm/s (error ≤ ± 10%)
- Bandwidth: Surgery 1~25 Hz
- Monitor 0.5~40 Hz
- Diagnostic 0.05-130 Hz
- Sensitivity: >200 μV P-P
- CMRR: ≥ 112dB
- Differential Input Impedance: >5M
- ohm Electrode Offset Potential:±300mV
Alarm
Three Level: Low, medium and high
Indication: Auditory and visual -Setup: Default and custom
Silence: All alarms can be silenced
Volume: 45-85 dB measured at 1 meter
Standard accessories
NIBP cuff & tube
ECG cable & electrodes SpO2 sensor
TEMP probe
Lithium-ion battery
Power cable Operator's manual
Technical specifications
|
Display
|
- 12.1"real color TFT Screen
|
Enviroment |
- Operating environment:
- Temperature: 0~40ºC
- Humidity:15%~80%
- Pressure :86.0 kPa~106.0 kPa
- Transport and Storage environment:
- Temperature: -20~55ºC
- Humidity:10%~90%
- Pressure:86.0 kPa~106.0 kPa
|
Power Requirements
|
- AC: 100 ~240V.50Hz/60Hz
- DC: Built-in rechargeable battery
- Battery: 11.1V 24wh Li-ion Battery
2h operating after full charge 5min operating after low battery alarm |
Application Range
|
-
- adult/Pediatric/Neonatal/Medicines/ Surgery
|
Date Storage |
- Trend diagram/table: 720h
- NIBP review:10000 events
- Wave review: 12h
- Alarm review:200 alarm events
- Suppert drug concentration titration analysis
|
ECG
|
·5 Leads: RA, LA, LL RL, V
·Lead mode: I,, ,m., AVR, AVL, AVF.V
·Gain: x 1.25 mm/mV, 2.5 mm/mV.
5.0 mm/mV, 10 mm/mV, 20mm/mV (error ≤ 5%) |
ST Segment
|
·ST Segment Range: -2.0 mV ~ + 2.0 mV
·Accuracy:0.02 mV
|
ECG. Sp02. NIBP. RESP. TEMP. PR.HR.
|
Alarm
|
- Three Level: Low, medium and high
- Indication: Auditory and visual
- Setup: Default and custom
- Silence: All alarms can be silenced
- Volume: 45-85 dB measured at 1 meter
|
Thermal Recorder (Option)
|
- Method: Thermal dot array
- Paper width:50 mm(1.97in)
- Paper Speed:12.5/25/50(mm/sec)
- Traces Maximum: 3 tracks
|
IBP (option)
|
- Channel: 2
- Measurement Range: -50~+300mmHg
- Unit: mmHg, kPa
- Accuracy:±2mmHgor2%,whichever is greater
|
EtC02(option, Microstream)
|
Range 0-19.7%(0-150 mmHg)
- Unit: %, mmHg: kP
- Respiration Rate Range 2-150 bpm
|
Optional accessories
|
|
Standard accessories
|
- NIBP cuff & tube
- ECG cable & electrodes
- SpO2 sensor
- TEMP probe
- Lithium-ion battery
- Power cable
- Operator's manual
|