Customization: | Available |
---|---|
Classification: | Biochemical Apparatus |
Type: | Biochemistry Analyzer |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Theory | Absorption spectrometry, transmission turbidimetry | |
Methodology | End-point \Fixed-time\Kinetic\Ion selective electrode | |
Test according set up, random access | Reaction plate | Contain 81 reaction cuvettes |
Maximum reaction time | 15 minutes | |
Minimum reaction volume | 150 ul | |
Material of cuvettes | Special UV-transparent optical glass | |
Cuvettes use | Automatically cuvettes washing | |
Optical Unit | Light Source | Halogen-tungsten lamp |
Photometer | Reversed optics | |
Wavelength | 340nm-900nm wavelength option | |
Absorption | 0-4 Abs | |
Reagent Unit | Reagent plate | 60 reagent positions ,support for single and double reagent, reagent completely open |
Reagent storage temperature | 2~10 degree | |
Reagent bottle | 15ml, 20ml, 30ml, 50ml or 70ml ,dead volume is less than 1.0 ml | |
Reagent volume | 20-500 ul, step by 1.0 ul | |
Reagent/Sample Probe | Automatically checked ;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside. | |
Sample Unit | Sample plate | 60 sample positions |
Sample type | Human (animal) serum \plasma\urine etc. | |
Samples cup | Support one-off micro cups | |
Sample volume | 2-100 ul, step by 0.1 ul | |
Sample/reagent probe | Automatically checked ;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside. | |
Temperature control Unit | Heating method | Direct thermal solid thermostat closed |
Temperature equilibrium time | <3 minutes | |
Reaction temperature | 37 ±0.1 degree | |
Temperature fluctuation | ±0.1 degree | |
Operation Unit | Software | WindowsXP \2000 |
Database | SQL Server | |
Data Storage | Automatic store & copy; No time and volume limit; Lifetime preservation | |
Print format | Can be set up, offer several standard format | |
Calibration mode | Linear curve type: Single-point linear, two-point linear and multi-point linear none linear; Curve type: Logistic-Log 4P,Logistic-Log5p,Spline,index automatically use best calibration curve and standard | |
Quality control methods : | Real time, within day & between day | |
Quality control diagram | L-J \cumulative\twin plot | |
Status display | Real time monitoring of reagent residual volume .Running status of reagent tray, samples tray | |
Adjustment | Dynamic and real time display of running status; Intelligent carry over settings to adjust test sequence; original reaction data record; Detail profile of alert messages | |
Setting | Operation permission setting, Item setting, cross pollution setting, cuvette blank setting | |
Others | Water consumption : < 6L/h | Power Supply :AC 220V±22V 50Hz±1Hz |
Frequency :Maximum 600VA | Dimension :782mm×581mm×545mm | |
Net Weight : 60kg | Accessory :Software |