YJ-V300B Medical Invasive Ventilator
YJ-V300B Medical invasive ventilator, suitable for rescue and ICU and other occasions, suitable for breathing support and rescue of people with weak or no spontaneous breathing.
Features:
- long term independent operation without external air supply (self-provided air supply) Operation control panel with clear LCD display, easy to operate
- compact fuselage, easy to install the ventilator in the crane tower or ambulance
- human-machine interface friendly, simple and intuitive operation Main engine of ventilator:
- applicable scope: adults, children
- driving mode: pneumatic electric control How it works: time switch
- ventilation mode: A/ c. A/C+SIGH, SIM(/2, f14), SPONT, Manual, Apnoea Ventilation
- pressure trigger sensitivity: -2-0pa
- oxygen concentration: 21%~ 100% continuously adjustable Silent alarm: no more than 120 seconds
Monitoring parameters: tidal volume, minute ventilation volume, total frequency, absorption ratio, peak pressure of airway pressure, oxygen concentration, automatic trigger
Alarm parameters: insufficient oxygen supply, upper limit of airway pressure, lower limit of airway pressure, power failure, continuous pressure, asphyxiation, lower limit of humidity, power failure, continuous pressure, asphyxiation, moisture
- power supply: AC220V, 50Hz
Humidifier:
- temperature control adjustment
- over - temperature automatic power-off protection
Overall performance:
- Pneumatic electric control, microcomputer control
- Monitor display: high-definition LED digital tube display
- Humidifier temperature control adjustment, automatic over-temperature power-off protection to meet the patient's long-term safety requirements
- Standard trolley for easy movement
- Optional UPS backup power supply and medical air compressor
- Maximum safe pressure of gas system: 6kPa
- Inhalation / exhalation impedance: no more than 0.6kPa at 30L / min flow rate
- System compliance: no more than 4mL / 100Pa
Ventilation mode:
A/C,A/C+SIGH,SIMVf/2,SIMVf/4,SPONT
Ventilation parameter settings:
- Tidal volume VT: 0 ~ 1500mL, resolution: 1mL
- Respiration frequency f: 4 ~ 60bpm, resolution / increment: 1bpm; range of SIMV is 2 ~ 30 bpm
- FiO2: 21% ~ 100%, continuously adjustable
- Peak pressure peak: 0 ~ 6kPa
- The breathing ratio I: E: 2: 1 ~ 1: 8 is adjustable
- Trigger sensitivity Psens: -2kPa ~ 0kPa, resolution / increment: 0.1kPa
- PEEP (optional): 0 ~ 2kPa
- Minute ventilation: max. Not less than 18 liters / minute
Monitoring parameters:
Tidal volume, minute ventilation, respiratory rate, peak airway pressure, oxygen concentration value, trigger
pressure
Operation method and instructions
A / C
(Assisted / Controlled Ventilation)
When you press this key, the upper left corner of the key lights up, and the ventilator executes this breathing mode. In A / C mode, when the patient's voluntary inspiratory pressure reaches the trigger pressure, the ventilator will deliver an assisted breath with a preset volume or pressure. When the patient's breathing frequency is lower than the set breathing frequency or the inspiratory pressure does not reach the trigger pressure, the ventilator provides controlled ventilation with preset parameters.
A / C + SIGH
(Assisted / Controlled Ventilation + Sigh)
When you press this key, the upper left corner of the key lights up, and the ventilator executes this breathing mode. In this mode, at least 1.5 times the tidal volume is supplied every 60 times during A / C.
SIMV f / 2
(Synchronized intermittent command ventilation)
When you press this key, the upper left corner of the key lights up, and the ventilator executes this breathing mode. In this mode, the frequency and tidal volume of spontaneous breathing are controlled by the patient, and synchronized instructions are executed at regular intervals to control the breathing. The commanded ventilation frequency is 1/2 of the original A / C ventilation frequency.
SIMV f / 4
(Synchronized intermittent command ventilation)
When you press this key, the upper left corner of the key lights up, and the ventilator executes this breathing mode. In this mode, the frequency and tidal volume of spontaneous breathing are controlled by the patient, and synchronized instructions are executed at regular intervals to control the breathing. At this time, the commanded ventilation frequency is 1/4 of the original set A / C ventilation frequency.
SPONT
(Spontaneous breathing + stress support Ventilation)
When you press this key, the upper left corner of the key lights up, and the ventilator executes this breathing mode. In this mode, the ventilator only provides a continuous positive pressure airflow to help the patient overcome the resistance to inhalation while the patient is breathing spontaneously. The patient's tidal volume, respiration rate, and breathing ratio are controlled by the patient. When the inhalation is stopped, the airway pressure rises, and when it rises to about 0.6kPa, the ventilator turns to exhalation, waiting for the next spontaneous breathing of the patient
The Products Catalogue
ICU Equipment |
Lab equipment |
Sterilizer |
Medical Cold Chain |
anesthesia machine |
Biochemistry Analyzer |
Ultrasound system |
BBR |
Medical ventilator |
Hematology analyzer |
X-ray |
Deep freeze |
Which include the following medical equipment:
Medical ventilator(Invasive and non-invasive) |
Medical Mask: FFP2, N95, KN95, Surgical Mask |
3-ply Face Mask(Surgical Mask,N95/FFP2/KN95 mask) |
Protective Mask |
Medical Googles |
Medical Gown |
Medical Isolation SUIT |
|
Packing & Delivery