Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Patient Monitor
Certification: CE, ISO13485
Group: Middle-aged and Old
Name: Defibrillator
Model: Yj-9000d
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Trading Company
  • Overview
  • Product Description
  • Company Profile
  • Shipping and Payment
Overview

Basic Info.

Model NO.
YJ-9000D
Transport Package
Carton
Trademark
FORERMED
Origin
China
Production Capacity
1000pieces/Month

Product Description

 

Product Description

 

Hospital Monophasic Cardiac Defibrillator ICU Medical Manual Defibrillator
Hospital Monophasic Cardiac Defibrillator ICU Medical Manual Defibrillator
Product name
Monophasic Defibrillator
Standard parameter & configuration
ECG, RESP, DEFIBRILLATOR
Physical characteristics:
Main unit
Portable
Dimensions
L320xW205xH410 mm
Weight
9.5kg
Technical specifications
DEFIBRILLATOR.
Defibrillator type
Manual, Synchronized, Asynchronized,
Out put waveform
Monophonic technology
Energy accuracy
∠+1%
Energy selection
0, 3, 5, 7, 10, 20,30, 50,100,200,300,360 joule(nominal at a resistance of 50)
Charging time
Maximum 8 seconds to 360 Joules
Standard Adult/Pediatric Paddles
Reusable external adult paddles(pediatric paddles integrated)
Power requirements.
AC Power supply
110V, 60 Hz /220V,50 Hz
Vehicle Voltage
 DC 12V
Internal Battery Backup
Battery type
Rechargeable lead-acid battery
Charging time
Time-Minimum of 4 hours for full charging
Battery charging
During AC Power Supply operation of the device.
Charging /Low Battery Indication
Red LED
Battery Capacity
100% of the battery will provide 120 mins of monitoring;
and 30 discharges at 360 joules.
Display
LED Dimensions
7'diagonal {155mm*88mm}
Type
High resolution true-color graphic LED
Resolution
480X234
ECG
ECG lead
1,2,3; AVR, AVL, AVF, V1~V6, GND S-T segment analysis: -2.0~2.0mv Arrhythmia analysis: yes Protection: With stand 4000vAc/50Hz
voltage in isolation and work against electrosurgical knife and defibrillation
Respiration
Measurement method: Thoracic impedance
Standard parameter & configuration
ECG/ RESP/DEFIBRILLATOR
Optional parameter
1. Recorder
2. Change be change to lithium battery.
Packing
1. Each one is packed
2. Individually in a carton
3. Package size:56×46×47cm
4. G.W.: 15.0Kg
5. N.W.: 9.5Kg

Hospital Monophasic Cardiac Defibrillator ICU Medical Manual DefibrillatorHospital Monophasic Cardiac Defibrillator ICU Medical Manual Defibrillator

Company Profile

 

Hospital Monophasic Cardiac Defibrillator ICU Medical Manual Defibrillator
Hospital Monophasic Cardiac Defibrillator ICU Medical Manual Defibrillator

Hospital Monophasic Cardiac Defibrillator ICU Medical Manual Defibrillator
Hospital Monophasic Cardiac Defibrillator ICU Medical Manual Defibrillator

Shipping and Payment

Hospital Monophasic Cardiac Defibrillator ICU Medical Manual Defibrillator

 


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now