Hospital Emergency Equipment Automated External Defibrillator Aed Biphasic Portable Defibrillator

Product Details
Customization: Available
Application: Hospital
Type: Box

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 14001, QC 080000, ISO 13485, EICC
International Commercial Terms(Incoterms)
FOB, CIF, CFR
  • Hospital Emergency Equipment Automated External Defibrillator Aed Biphasic Portable Defibrillator
  • Hospital Emergency Equipment Automated External Defibrillator Aed Biphasic Portable Defibrillator
  • Hospital Emergency Equipment Automated External Defibrillator Aed Biphasic Portable Defibrillator
  • Hospital Emergency Equipment Automated External Defibrillator Aed Biphasic Portable Defibrillator
  • Hospital Emergency Equipment Automated External Defibrillator Aed Biphasic Portable Defibrillator
  • Hospital Emergency Equipment Automated External Defibrillator Aed Biphasic Portable Defibrillator
Find Similar Products
  • Overview
  • Product Description
  • Features
  • Technical specifications
  • Detailed Photos
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
YJ-D9000
Size
Small
Logo Printing
Without Logo Printing
Group
All
Feature
Reusable
Product Name
Defibrillator
SpO2 Module Measurement Range
30~100%
Color
Blue
LCD Display
with LCD Display
Display
7 Inches High-Resolution Display
Waveform
Biphasic
Transport Package
Standard Express Package
Specification
490*340*460
Trademark
Foremred
Origin
China
HS Code
9001100001
Production Capacity
1000000

Product Description


Product Description

YJ-D9000 Defibrillator Monitor 
 

Hospital Emergency Equipment Automated External Defibrillator Aed Biphasic Portable Defibrillator

 YJ-D9000 is a professional biphasic defibrillator-monitor suitable

* Compact Durable 
* Light weighted defibrillator 
* Multi-parameter Patient Monitor Manual defibrillation 
* Automated External Defibrillalator(AED) pacer (option) 
* 5 Lanquages to choose
 

Features

 
Hospital Emergency Equipment Automated External Defibrillator Aed Biphasic Portable Defibrillator
SpO2 Module (Options)
Measurement Range: 30~100% +2%
between 80%~90% others +5%
Alarm : User set high and low limit.
Alarm Accuracy: t10% within setting value Alarm time
Accuracy: less than 12 sec.
Mieditech Pulse Oximeter
Hospital Emergency Equipment Automated External Defibrillator Aed Biphasic Portable Defibrillator
ECG Monitoring
3-lead ECG cable or 5-lead ECG cable
Display: I II AVR AVL AVF V.
ECG Size: 0.25 0.5 1 1.5 2 4 cm/mV
Heart Rate: 20-300GPM
Hospital Emergency Equipment Automated External Defibrillator Aed Biphasic Portable Defibrillator
NIBP Module (Options)
Adult SYS 30~270 mmHg DIA10-220 mmHg MEAN 20~235 mmHg

Child SYS 30~235 mmHg DIA.10~220 mmHg MEAN 20~225 mmHg

Neo SYS 30~135 mmHg DIA 10~110 mmHg MEAN 20~125 mmHg


 
ECG Monitoring 

1.3-lead ECG cable or 5-lead ECG cable
2.Display: I II AVR AVL AVF V.
3.ECG Size: 0.25 0.5 1 1.5 2 4 cm/mV
4.Heart Rate: 20-300GPM 
Hospital Emergency Equipment Automated External Defibrillator Aed Biphasic Portable Defibrillator

Display 
1.Screen Type: High-resolution display
2.Screen Size: 8 inch
3.Languages: 5toChoose
4.Sweep Speed: 25mm/sec
5.Information: Heart Rate.Lead/Pads.Alarm On/OffSp2AED Functions and Prompts Alarm
6.Selection and Limits Delivered Energy
7.5 Languages available: English.Russian. Spanish.
Chinese.Turkish

Defibrillator 
1.Waveform:Biphasic 
2.Charge Time: Less than 7 seconds with a new fully charged battery. 
3.Energy Display: Monitor display indicates both selected and delivered energy Charge Prompt 
4.Type: Voice and visual prompts. 
5.Electrode Impedance Measurement Range:0-250ohms


EGG Monitoring 
1.Patient Connection: 3-lead ECG cable or 5-lead ECG cable paddles. 
2.Lead Selection: Displayed on monitor paddles I II AVR AVL AVF V 
3.ECG Size: 0.25 0.5 1 1.5 2 4 cm/mV display on monitor. 
4.Heart Rate:20-300BPM. 
5.Heart Rate Alarm: On/Off displayed on monitor user-selectable 
6.Smart Alarms: Beeper/voice prompts indicate shock able rhythm.

 
SP02 Module [Options]
1.Measurement Range:30~100%+2% between 80%~90% others±5%
2.Alarm Range: User set high limit and low limit.
3.Alarm Accuracy:+10% within setting values.
4.Alarm time Accuracy: less than 12 sec.
5.1-Meditech Pulse Oximeter 
 

Recorder 
1.Paper: 50mm thermal. 
2.Speed: 12.5mm/sec25mm/sec50mm/sec. User-selectable 6-second delay 
3.Printing Method: High-resolution thermal print head. 
4.Print-out Modes: Manual or automatic user-configurable. 5.On/Off Control: Front panel and paddle. 
6.Automatic Function: 9-seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge.

 
AED Mode
1.AED Function: Auto analyze and charge x3 with
programmable auto energy level selection screen prompts and voice prompts.
2.Shockable Rhythms: Ventricular fibrillation with amplitude >=200uVventricular tachvcardia with rates >=140bpm and ORScomplex wave duration>=140ms
3.Charge Control: Control on device front panel press key on paddle
4.Prompts: Voice and visual prompts.

 

Technical specifications

 
Technical specifications
Display 
Screen Type
High-resolution display
Screen Size
8 inches diagonally
Sweep Speed
25mm/sec
Information
Heart Rate, Lead/Pads, Alarm On/Off, SpO2, AED
Defibrillator
Waveform
 Biphasic
Charge Time
Less than 7 seconds with a new fully charged battery.
Energy Display
Monitor display indicates both selected and delivered energy.
Charge Prompt Type
Voice and visual prompts.
Electrode Impedance Measurement Range
 0- 250 ohms
                                                                                                             
ECG Monitoring
Patient Connection
3-lead ECG cable, or 5- lead ECG cable, paddles
Lead Selection
Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V.
ECG Size
0.25, 0.5, 1, 1.5, 2, 4 cm/mV display on monitor.
Heart Rate
20-300BPM
Heart Rate Alarm
On/Off displayed on monitor, user-selectable
Smart Alarms
Beeper/voice prompts indicate shock able rhythm
Battery
Type
Rechargeable, Ni- MH battery, 12V
Operating Time
For a new, fully charged battery: 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring. Additional parameters will affect operating time with different functions.

                                                                     
SpO2 Module
Measurement Range
30~100%, ±2% between 80%~90%, others ±5%
Alarm Range
User set high limit and low limit
Alarm Accuracy
 ±10% within setting values
Alarm time Accuracy
less than 12 sec

Detailed Photos

 

Hospital Emergency Equipment Automated External Defibrillator Aed Biphasic Portable Defibrillator
Hospital Emergency Equipment Automated External Defibrillator Aed Biphasic Portable Defibrillator
Hospital Emergency Equipment Automated External Defibrillator Aed Biphasic Portable Defibrillator
Hospital Emergency Equipment Automated External Defibrillator Aed Biphasic Portable Defibrillator


 

Company Profile


Hospital Emergency Equipment Automated External Defibrillator Aed Biphasic Portable DefibrillatorHospital Emergency Equipment Automated External Defibrillator Aed Biphasic Portable Defibrillator
Hospital Emergency Equipment Automated External Defibrillator Aed Biphasic Portable Defibrillator


 

FAQ


Hospital Emergency Equipment Automated External Defibrillator Aed Biphasic Portable Defibrillator

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier