YJ-T60 Trolley Color Doppler Ultrasound machine 2D ECHO
Wide range of applications
The systemic application type is mainly used in the diagnosis and research of Abdominal, OB&GYN ,Cardiac,Urinary, Small Parts, Superficial, Vascular, Pediatrics (neonatal), Emergency, Physical examination and other aspects of examination and diagnosis.
It has the application capabilities of cardiovascular, peripheral blood vessels, obstetrics and gynecology, abdomen, fetal heart, superficial tissues and small organs, intraluminal and puncture interventional ultrasound with powerful 4D analysis functions.
Fine core wisdom perception super clear
Intelligent operation process, humanized appearance design, so that doctors in the clinical diagnosis process will pay attention to the patient itself
Features:
1. Elastography
Smooth Workflow
The whole is elegant and beautiful, the diagnostic measurement package is rich and comprehensive, and the operation process is simple and fast.
1: | Summary of main specifications and system of cart type color Doppler ultrasound | ||
1.1 | Trolley type all digital color Doppler ultrasonic mainframe | ||
1.2 | Ultrasonic host operating system: Windows operating system | ||
1.3 | Applications: Abdomen, obstetrics, gynecology, heart, urinary system, small organs, superficial, blood vessels, pediatrics, newborns, musculoskeletal |
||
1.4 | Probes: Convex probe, Tran-vaginal probe, Linear probe, Micro-convex probe, Cardiac probe,4D Volume probe |
||
1.5 | Applications and report: Abdominal,OB,GYN,Cardiac,Urinary,Small Parts,Superficial, Vascular, Pediatrics, Advanced measurement software packages, report software packages, case management software packages, etc. |
||
☆1.6 | carotid artery intima-media thickness(IMT) | ||
☆1.7 | Automatic spectral envelope measurement | ||
1.8 | Full digital transmission and reception of beam synthesizer | ||
1.9 | Color Doppler imaging(C) | ||
1.10 | Pulse Doppler Imaging(PW) | ||
☆1.12 | Coherent Contrast imaging(CCI) | ||
1.12 | Continuous wave Doppler imaging(CW) | ||
☆1.13 | B/C/D Real-time three synchronous imaging | ||
☆1.14 | Power Doppler imaging(PDI) | ||
☆1.15 | Direct power Doppler imaging(DPDI) | ||
1.16 | M mode imaging | ||
☆1.17 | Anatomic M mode imaging | ||
☆1.18 | Color Doppler M mode imaging | ||
☆1.19 | Elastography | ||
☆1.20 | Tissue Doppler imaging(TDI) | ||
☆1.21 | Strain rate imaging (SRI) | ||
1.22 | Tissue harmonic imaging(THI) | ||
1.23 | Fusion harmonic imaging(FHI) | ||
1.24 | Speckle Reduce imaging(SRI) | ||
☆1.25 | Panoramic imaging | ||
☆1.26 | Deflection imaging | ||
☆1.27 | Trapezoidal imaging | ||
1.28 | Adaptive velocity optimization | ||
☆1.29 | Free hand 3D | ||
1.30 | Real time 3D imaging(3D/4D) | ||
1.31 | DICOM3.0 | ||
1.32 | Monitor:≥21.5 inch,high definition ultrasonic display | ||
1.33 | ≥13.3 inch touch screen | ||
1.34 | Physical clipboard: save the image on the left side of the screen, which can be directly saved or deleted. | ||
1.35 | The system has the function of on-the-spot upgrade | ||
1.36 | Presupposition: for different inspection of the viscera, preset the inspection conditions for the best image, reduce the adjustment of the operation, and the commonly used external adjustment and combination regulation. | ||
1.37 | Probe interface: 4 | ||
1.38 | Language: ZH/EN/VI/DE/FR/ES/RU/AR/PT/IN | ||
1.39 | Depth:≥410mm; | ||
1.40 | Extended imaging | ||
2: | Probes | ||
2.1 Convex probe | Fundamental Frequency:2.0MHz/2.3MHz/2.5MHz/3.0MHz/3.5MHz/4.0MHz/4.6MHz/5.0MHz/5.4MHz, Harmonic Frequency: 4.0MHz/4.6MHz/5.0MHz |
||
2.2 Linear probe |
Fundamental Frequency:4.0MHz/4.6MHz/5.0MHz/6.0MHz/7.0MHz/8.0MHz/9.2MHz/10.0MHz/12.0MHz/13.3MHz, Harmonic Frequency: 8.0MHz/9.2MHz/10.0MHz |
||
2.3 Trans-vaginal probe | Fundamental Frequency: 3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz/10.0MHz, Harmonic Frequency: 6.0MHz/7.0MHz/8.0MHz |
||
2.4 Micro-convex probe | Fundamental Frequency: 3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz, Harmonic Frequency: 6.0MHz/7.0MHz/8.0MHz |
||
2.5 Cardiac probe adult | Fundamental Frequency:1.7MHz/1.9MHz/2.1MHz/2.5MHz/3.0MHz/3.4MHz/3.8MHz/4.2MHz/5.0MHz, Harmonic Frequency: 3.4MHz/3.8MHz/4.2MHz |
||
2.6 Cardiac probe pediatric | Fundamental Frequency:3.0MHz/ 3.5MHz/ 4.0MHz/ 5.0MHz/ 5.4MHz/6.0MHz/7.0MHz/8.0MHz Harmonic Frequency: 6.0MHz |
||
2.7 4D Volume probe |
Fundamental Frequency: 2.0MHz/2.5MHz/3.0MHz/3.3MHz/3.7MHz/4.0MHz/5.0MHz/6.0MHz, Harmonic Frequency: 4.0MHz/5.0MHz/6.0MHz |
||
3: | 2D imaging mode | ||
3.1 | Gain:0-100,Step 2 adjustable | ||
3.2 | TGC:8 segment adjustable | ||
3.3 | Maximum focus point:≥7, which can be moved throughout the whole process. | ||
3.4 | Speckle reduction:0-5,5 level | ||
3.5 | Space Synthesis:0-2,2 level(Liner probe: 3 level, cardiac probe:0) | ||
3.6 | Dynamic:30-180,35 level,step 5 adjustable | ||
3.7 | Line density:low,middle,high,3 level | ||
3.8 | Frame correlation:0-4,4 level | ||
3.9 | Noise reduction:0-5,5 level | ||
3.10 | Edge Enhancement:0-5,5 level | ||
3.11 | Sound power:2-10, 9 level | ||
3.12 | Grey scale:0-67, 67 level | ||
3.13 | False color:0-67,67 level | ||
3.14 | Image style:Soft-Comparison,2 level | ||
The screen has real-time display of voice power, probe frequency, dynamic range, pseudo color, gray scale and other 11 parameters can be adjusted | |||
4: | Color Doppler imaging mode | ||
4.1 | Blood gain:0-100,Step 2 | ||
4.2 | Parameter display:Velocity,Variance | ||
4.3 | B-Restrain(B/W restrain):0-7, 7 level | ||
4.4 | Speed Through:0-8, 8 level | ||
4.5 | Sampling number:6-24, 7 level | ||
4.6 | Blood flow preferred:0-8, 8 level | ||
4.7 | Filtering:1-6, 6 level | ||
4.8 | Sound power:2-6, 4 level | ||
4.9 | Noise reduction:0-4, 4 level | ||
4.10 | Smooth treatment:0-4, 4 level | ||
4.11 | Frame correlation:0-6, 6 level | ||
4.12 | Chromatography(Blood flow graph):0-37, 37 level | ||
4.13 | Line density:Low-Middle-High, 3 level | ||
4.14 | Frequency:4 level adjustable | ||
4.15 | Velocity:Minimum 0.4K,Maximum 40.5K Convex probe:0.4K-4.3K-38.5K Linear probe:0.4K-14.7K-39.0K Trans-vaginal probe:0.4K-7.8K-39.7K Volume probe:0.4K-4.2K-34.8K Micro-convex probe:0.4K-10.3K-40.5K cardiac probe:0.4K-7.8K-39.7K |
||
PS:The frequency of the probe changes and the frequency value changes | |||
PS:Frame rate changes with speed | |||
5: | Pulse wave Doppler(PW) | ||
1 | Gain:0-100,Step 2 | ||
5.2 | Spectrum envelope function: real time automatic spectrum envelope, manual spectrum envelope, and other modes. The system automatically analyses and displays various data such as PSV, EDV, RI, PI, S/D, ACC, HR and so on. Can wake up or close | ||
5.3 | Sample volume:0.5mm~30mm | ||
5.4 | Blood angel:-75-75 degree,Step 5 | ||
5.5 | False color:0-67, 67 level | ||
5.6 | Dynamic range:20-40, 4 level | ||
5.7 | Filter:0-9, 9 level | ||
5.8 | Smooth treatment:1-4, 4 level | ||
5.9 | Sound power:2-5, 4 level | ||
5.10 | Volume:0-100, 10 level,Step 10 | ||
5.11 | Audio filtering:0-4, 4 level | ||
5.12 | Base line:-1.0~1.0, | ||
5.13 | Grey map:0-67, 67 level | ||
5.14 | Scan velocity:100-500, 6 level | ||
5.15 | PRF:Minimum 0.5K,Maximum 87.5K Convex probe:0.5K-4.3K-63.3K Linear probe:0.5K-14.5K-78.4K Trans-vaginal probe:0.5K-8.1K-78.4K Volume probe:0.5K-4.2K-53.8K Micro-convex probe:0.5K-10.3K-81.1K cardiac probe:0.5K-4.3K-87.5K |
||
5.16 | Frequency:4 level | ||
PS:The frequency of the probe changes and the PRF value changes | |||
PS:The frequency of the probe changes and the frequency value changes | |||
6: | Continuous Wave Doppler(CW) | ||
6.1 | Support probe:Cardiac probe | ||
6.2 | Adjustment of B mode parameters is switchable | ||
6.3 | Gain:0-100,Step 2 | ||
6.4 | Sampling line position is adjustable | ||
6.5 | PRF:0.9K~36.1K | ||
6.6 | Baseline:-1.0~1.0 | ||
6.7 | Blood angel:-75~75 degree | ||
6.8 | Grey map:0-67 | ||
6.9 | Scan velocity:100-300 | ||
6.10 | False color:0-67 | ||
6.11 | Dynamic range:20-40 | ||
6.12 | Filtering:0-9,9 level | ||
6.13 | Smooth treatment:1-4 | ||
6.14 | Frequency:2.0MHz/2.3MHz/2.5MHz/3.0MHz,4 level adjustable | ||
6.15 | Sound power:2-5 | ||
6.16 | Volume:0-100 | ||
6.17 | Audio Filtering:0-4 | ||
☆7: | Anatomical M imaging | ||
7.1 | Support probe:Convex probe, Linear probe,Cardiac probe | ||
7.2 | Adjustment of B mode parameters is switchable | ||
7.3 | Gain:0-100,Step 2 | ||
7.4 | M Sampling line angel is adjustable | ||
7.5 | M Sampling line length is adjustable | ||
7.6 | Sampling line:3,Can be displayed or hidden separately | ||
☆8: | Blood flow M mode(MC) | ||
8.1 | Adjustment of B mode parameters is switchable | ||
8.2 | Gain:0-100,Step2 | ||
8.3 | MC Sampling line angel is adjustable | ||
8.4 | MC Sampling line length is adjustable | ||
8.5 | Frequency:4 level | ||
8.6 | Sampling number:6-24 | ||
8.7 | Speed through:0-8, 8 level | ||
8.8 | Scan velocity:150-500 | ||
8.9 | Frame correlation:0-6, 6 level | ||
8.10 | Filtering:1-6,6 level | ||
8.11 | Blood flow preferred:0-8,8 level | ||
8.12 | Smooth treatment:0-4,4 level | ||
8.13 | Map:0-37, 37 level | ||
☆9: | Elastography | ||
9.1 | Adjustment of B mode parameters is switchable | ||
9.2 | Gain:0-100,Step 2 | ||
9.3 | B/E,Double real-time display on the same screen | ||
9.4 | Probe displacement curve display:Up/Down | ||
9.5 | Pressure indicator bar display | ||
9.6 | Frequency:8-9 level,Adjustable;According to the probe display | ||
9.7 | Noise reduction:0-2, 2 level | ||
9.8 | Frame correlation:0-3, 3 level | ||
9.9 | Comparison:0-13, 13 level | ||
9.10 | False color:0-3, 3 level | ||
9.11 | Don't support cardiac probe | ||
☆10: | Tissue Doppler imaging(TDI) | ||
10.1 | Support probe: Cardiac probe | ||
10.2 | Adjustment of B mode parameters is switchable | ||
10.3 | Gain:0-100,step 2 | ||
10.4 | ROI area adjustable | ||
10.5 | Sampling number:6-24 | ||
10.6 | Velocity:0.4K-8.0K | ||
10.7 | Frame correlation:0-6,6 level | ||
10.8 | Tissue preferred:0-7, 7 level | ||
10.9 | Frequency:2.0MHz/2.3MHz/2.5MHz/3.0MHz | ||
10.10 | Support color reversal | ||
☆11: | Strain rate imaging | ||
11.1 | Support probe: Cardiac probe | ||
11.2 | Adjustment of B mode parameters is switchable | ||
11.3 | ROI area adjustable | ||
11.4 | Gain:0-100,Step 2 | ||
11.5 | Sampling number:6-24,6 level | ||
11.6 | Axial average:1-4, 4 level | ||
11.7 | Velocity:0.4K-8K | ||
11.8 | Frame correlation:0-6, 6 level | ||
11.9 | Tissue optimization:0-7,7 level | ||
☆12: | Panoramic imaging | ||
12.1 | Support probe:Linear probe | ||
12.2 | Speckle Reduction:0-5, 5 level | ||
☆13: | Deflection imaging | ||
13.1 | Support probe:Linear probe | ||
13.2 | Adjustment of B mode parameters is switchable | ||
13.3 | Deflection angel:8 level | ||
13.4 | Speckle reduction:0-5, 5 level | ||
13.5 | Dynamic rate:30-180,Step 5 | ||
13.6 | Line density:low-middle-high,3 level | ||
13.7 | Frame Correlation:0-4, 4 level | ||
13.8 | False color:0-67, 67 level | ||
13.9 | Image style:Soft-Comparison,2 level | ||
13.10 | Noise reduction:0-5, 5 level | ||
13.11 | Edge Enhancement:0-5,5 level | ||
13.12 | Sound power:2-10,8 level | ||
13.13 | Grey map:0-67,67 level | ||
☆14: | Trapezoidal imaging | ||
14.1 | Probe support:linear probe | ||
14.2 | Adjustment of B mode parameters is switchable | ||
14.3 | Deflection angel:8 level | ||
14.4 | Speckle reduction:0-5, 5 level | ||
14.5 | Dynamic rate:30-180,Step 5 | ||
14.6 | Line density:low-middle-high,3 level | ||
14.7 | Frame Correlation:0-4, 4 level | ||
14.8 | False color:0-67, 67 level | ||
14.9 | Image style:Soft-Comparison,2 level | ||
14.10 | Noise reduction:0-5, 5 level | ||
14.11 | Edge Enhancement:0-5,5 level | ||
14.12 | Sound power:2-10,8 level | ||
14.13 | Grey map:0-67, 67 level | ||
14.14 | Space Synthesis:0-2, 2 level | ||
☆15 | Freehand 3D imaging | ||
15.1 | Support probe:convex probe, linear probe | ||
15.2 | Display model: 4 pictures | ||
15.3 | Image Rotation X/Y/Z Axis | ||
15.4 | Multi-slice Visibility | ||
16 | Real-time 4D imaging | ||
16.1 | Support probe: 4D volume probe | ||
16.2 | Adjustment of B mode parameters is switchable | ||
16.3 | Gain:0-100,Step 2 | ||
16.4 | Display model:one image,two images,four images | ||
16.5 | Image Rotation:X/Y/Z Axis | ||
16.6 | Multi-slice Visibility | ||
16.7 | Light&Shade inversion | ||
16.8 | Smooth:0-4, 4 level | ||
16.9 | Threshold level:0-129, Step 3 | ||
16.10 | Transparency:1-509,Step 10 | ||
16.11 | Render type:4 kinds,Surface,maximum,minimum,perspective | ||
17: | Panoromic Imaging | ||
17.1 | Gain:0-100,Step 2 | ||
17.2 | TGC:8 segment adjustable | ||
17.3 | Maximum focus point:≥7, which can be moved throughout the whole process. | ||
17.4 | Speckle reduction:0-5,5 level | ||
17.5 | Space Compound:0-2,2 level(Linear probe: 3 level,don't support cardiac probe) | ||
17.6 | Dynamic range:30-180,35 level,Step 5 | ||
17.7 | Line density:Low,Middle,High,3 level | ||
17.8 | Frame correlation:0-4,4 level | ||
17.9 | Noise reduction:0-5,5 level | ||
17.10 | Edge enhancement:0-5,5 level | ||
17.11 | Sound power:2-10, 9 level | ||
17.12 | Grey map:0-67, 67 level | ||
17.13 | False color:0-67,67 level | ||
17.14 | Image style:Soft-Comparison,2 level | ||
17.15 | Extended level: Maximum 72 level Convex probe:9 level Trans-vaginal probe:72 level Micro-convex probe:29 level Cardiac probe:40 level 4D Volume probe:17 level |
||
PS:The screen has real-time display of voice power, probe frequency, dynamic range, pseudo color, gray scale and other 11 parameters can be adjusted | |||
PS: When the probe scan range reaches the maximum, the space synthesized is 0. | |||
18: | Measurement and analysis function: | ||
18.1 | General measurement: Distance, area, ellipse, cross line, angle, distance ratio, volume, Volume (ellipse), area ratio, diameter, joint angle | ||
18.2 | Cardiac:Automatic spectrum envelope,LV,Main Pulmonary artery diameter,RVEDd,RVEDs,LVM,LAV,HR,MVF,AO,AR,LVOT,TVF,Pulmonic valve,Pulmonary vein,RV,Doppler fetal heart sound,LVET,LVM,LVMI,AV | ||
18.3 | Vascular: carotid intima (IMT), length stenosis ratio, area stenosis ratio, IMT (back wall), IMT (front wall) | ||
18.4 | OB:Fetal routine,AFI,TW,GS,CRl,OFD,HL,ulna,NT,Fibula,Nbonel,Radial,Tibia | ||
18.5 | GYN:uterus,cervix,corpus uteri/cervix uterus,left ovarian vein,right ovarian vein,dominant follicle,intima thickness | ||
18.6 | Urology: prostate,residual urine,left kidney,right kidney,left suprarenal vein,right suprarenal,left testis,right testis,left seminal vesicle,right seminal vesicle | ||
18.7 | Abdomen:liver,CHD,partal vein diameter,cholecyst ,pancreas,spleen,Internal diameter of abdominal aorta,kidney | ||
18.8 | Small parts:Thyroid | ||
18.9 | Software package:Measurement package,Software package,Medical records management software package | ||
19: | Graphic and text management system | ||
19.1 | Host build in 2 hard disk (SSD 128GB+ HDD 1TB), Start fast and stable, RAM: 8GB | ||
19.2 | Movie playback:≥1200 frames | ||
19.3 | Internal file information management system: can record patient number, name, check number, check date and so on, and can be searched and managed by numbering, checking number, name and so on. | ||
19.4 | Type of report is 16 | ||
19.5 | One key fast report graphic and text management | ||
20: | Interface | ||
20.1 | USB interface: *4 | ||
20.2 | HDMI interface: *1 | ||
20.3 | RJ-45 interface: *1 | ||
20.4 | Grounding wire interface: *1 | ||
20.5 | Fuse: *2 | ||
20.6 | DVD RW: *1 | ||
21: | Configuration | ||
21.1 | Trolley type full digital color Doppler ultrasound diagnostic system | ||
21.2 | Probe: convex array probe (standard), linear probe (optional), Trans-vaginal probe (optional), cardiac probe (optional), 4D volume probe (optional) | ||
21.3 | ≥13 quick adjusting knobs | ||
22: | Technology, after-sales service and other requirements | ||
22.1 | After acceptance, the warranty is free for two years(Provide manufacturer warranty certificate) | ||
22.2 | Manufacturer has ISO13485 certification and EU CE certification. |