The B-Autoclave 3 L has a particularly compact design and allows sterilization in a super fast time of 10 minutes. The clear menu can be operated via a color touch screen. This mini autoclave is equipped with an SD card to easily register sterilization programs. Moreover, this B-Autoclave 3 L also has an internal printer. The water tanks make it possible to carry out the sterilization process without connecting to a water supply.
Perfect for sterilization of small instruments
Sterilization is possible in 10 minutes using the quick program. This compact B-Autoclave with a capacity of 3 liters is perfect for sterilizing small instruments. Incidentally, this mini autoclave is also suitable for medium-sized instruments. Two trays are provided and in addition to the programs for sterilizing instruments, test programs are available. The autoclave is small but very powerful and dries intelligently. For larger instruments, B autoclaves are available with more capacity.
This autoclave is ideal for dental practices and eye clinics.
DESCRIPTION
New 3-liter class B autoclave that stands out for having an extraordinary ultra-fast sterilization cycle of only 10 minutes, including drying , which sets the difference compared to its range competitors.
It has a printer, an SD card connection and a large and clear touch screen.
It is compact and small in size and includes multiple features for its safe and easy use.
Designed specifically for clinics, hospitals, laboratories and other settings where frequent sterilization is required.
PROGRAMS:
Program |
Temperature |
Wait time |
Pre-vacuum time |
Drying time |
134 ºC universal fast |
134 |
4 |
3 |
4 |
134 ºC universal |
134 |
4 |
3 |
6 |
134 ºC solid |
134 |
4 |
1 |
2 |
121 ºC universal |
121 |
4 |
3 |
8 |
B & D / Helix test |
134 |
3.5 |
3 |
4 |
Vacuum test |
Vacuum to -80 kPa (15 minutes) |
Vacuum to -80 kPa (15 minutes) |
Vacuum to -80 kPa (15 minutes) |
Vacuum to -80 kPa (15 minutes) |
Drying |
- |
- |
- |
5 minimum |
TYPE OF LOAD:
- 134 ºC universal fast: Unpacked load or packed solid load, textile and hollow instrument.
- 134 ºC / 121 ºC universal version: Unpacked load or packed solid load, textile and hollow instrument.
- 134 ºC solid: Unpackaged solid load for use immediately after sterilization.
- B & D / Helix test: BD test device or PCD test device.
- Vacuum test: No load.
- Drying: Drying when not dry after sterilization.
CHARACTERISTICS:
- Ultra-fast 10 minute sterilization cycle, including drying.
- Touch screen, for easy use, which will dynamically display the parameters and the status of the operation.
- Printer and connection for SD card.
- Compact and small in size.
- Aluminum alloy chamber for optimal drying.
- Memory for up to 20 sterilization cycles.
- 7 sterilization cycles available.
- Automatic fault diagnosis, temperature too high, automatic overpressure protection to ensure the effectiveness of sterilization and disinfection.
TECHNICAL DATA:
- Camera Specifications:
- Measurements (width x height x depth): 175 mm x 55 mm x 280 mm
- Pressure: -0.1 / 0.27 MPa;
- Temperature: 140 ºC
- Autoclave parameters:
- Maximum operating temperature: 137 ºC
- Maximum working pressure: 0.24 MPa
- Valve set pressure: 0.24 MPa
- Clean water tank capacity: 2L
- Sewage tank capacity: 0.8L
- Power input: 230V ± 23V, 50Hz, 2900VA
- Sound level: <= 60dB
- Maximum heat output: 2800KJ / h
- Environmental requirements for use:
- Ambient temperature: 5 ºC ~ 40 ºC;
- Relative humidity: ≤ 85%;
- Ambient atmospheric pressure: 80k Pa, ~ 106kpa
- Others:
- General measurements (width x height x depth): 36.5 cm x 28 cm x 58 cm
- Weight: 32 kg
NORMATIVE:
- 93 / 42EEC - Medical Device Directive
- EN13060: 2014 - Small Steam Sterilizers
- EN61326-1: 2013 - Electrical material for measurement, control and laboratory use. Electromagnetic compatibility (EMC) requirements
- EN61010-1: 2010 + A1: 2019 - Safety requirements for electrical equipment for measurement, control and laboratory use. Part 1: General requirements.
- EN61010-2-040: 2015 - Safety requirements for electrical equipment for measurement, control and laboratory use. Part 2-40: Particular requirements for sterilizers and for washing and disinfection equipment used for the treatment of medical materials.
ACCESSORIES INCLUDED:
- Instrument trays (2).
- Base for trays.
- Handle to extract the trays.
- Drain hose.