Customization: | Available |
---|---|
Classification: | Imaging Diagnostic Equipment |
Type: | Ultrasound Scanner |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Anesthesia Machine | |
Model | YJ-A805 |
Part of Anesthesia Machine | |
Main body | High-strength engineering plastic rack, light, beautiful and corrosion resistant |
Scope of application | adult, child(4 years above) |
Gas source | O2, N2O, Air: 0.28~0.6MPa |
Flow meter | O2,N2O: 0.05-1.0L/min 1.1-10L/min Air:0. 05-10L/min |
O2,N2O linkage and N2O Stopper | When using nitrous oxide, oxygen concentration>25%. When the oxygen pressure<0.2MPa, the flow of nitrous oxide would be cut off. |
Vaporizer | Two, high-precision evaporator |
Part of Ventilator | |
Display mode | 10.4" TFT |
mode | IPPV, SIPPV, SIMV,MANUAL, VCV, PCV |
function | PEEP,SIGH, IRV, IP, standby |
TV | 20~1600 ml |
Rate | 2~99 bpm |
SIMV rate | 2~20 bpm |
I:E | 4:1~1:8 |
Inspiratory trigger pressure | -10~20cmH2O |
PEEP | 2~20cmH2O |
Pressure limitation | 5~60 cmH2O |
SIGH | IGH 1.5 times the inspiratory time (60-120 adjustable) |
Inspiratory platform | 0~50% |
Pressure control | 3~50 cmH2O |
Pressure slope | 1~10 gear |
Power | AC 220V 50Hz (UPS, Storage battery) |
Parameters for ventilation monitoring |
B1, B2, B4: tidal volume, minute ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, pressure - time waveform, flow - time waveform, PEEP, inspiratory trigger pressure B3, B5: tidal volume, minute ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure, inhale tidal volume, inspiratory platform, average pressure, autonomous inspiratory rate, oxygen concentration, battery capacity, flow-volume loop, pressure-volume loop |
Mechanical Arms | YES |
End-tidal CO2monitoring | Optional |
Part of Anesthesia | ||
Main body | High-strength engineering plastic rack, light, beautiful and corrosion resistant |
|
Scope of application | adult, child | |
Gas source | O2: 0.28~0.6MPa | N2O: 0.28~0.6MPa |
Flow meter | O2 : 0.05~10L/min | N20: 0.05~10L/min |
O2 N2O linkage and N2O Stopper | When using nitrous oxide, oxygen concentration>25%; | |
When the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off. |
||
Flow rate of rapid oxygen supply |
25~75L/min | |
Low oxygen pressure alarm | There will be sound alarm when the oxygen pressure < 0.2MPa |
|
Vaporizer | It has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0~5 vol%. Among Halothane,Enflurane, Isoflurane and Sevoflurane, one can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available. | |
Respiratory circuit | working mode: all-close, semi-close, semi-open | |
APL≤12.5 kPa | ||
Respiratory Bellows | bellows for adults, tidal volume range:0~1500 ml | |
bellows for children, tidal volume range:0~300 ml | ||
anyone can be chosen for application as required by the customer |
||
Display mode | High-definition 5.7" LCD screen display | |
Part of Ventilator | ||
Ventilation mode | IPPV, SIPPV, SIMV, MANUAL | |
Ventilation functions | PEEP,SIGH, IRV | |
Ventilation parameters | Tidal volume | 50~1500 ml |
Rate | 2~99 bpm | |
SIMV rate | 2~20 bpm | |
I:E | 2:1~1:8 | |
Inspiratory trigger pressure | -10~20 cmH2O | |
PEEP | 2~20 cmH2O | |
Pressure range | 5~60 cmH2O | |
SIGH | 1.5 times the inspiratory time (60-120 adjustable) |
|
Parameters for ventilation monitoring | Expired tidal volume, Inhale tidal volume, minute ventilation volume, IPPV rate, SIMV rate, total respiratory rate, autonomous inspiratory rate, I/E, peak pressure of airway, average pressure, PEEP, inspiratory trigger pressure |
|
Security Alarm System | ||
Airway pressure alarm | upper limit setting range 5~60 cmH2O | |
low limit setting range 0~50 cmH2O | ||
Per-minute ventilation volume alarm | upper limit setting range 1~20L/min | |
low limit setting range 0~19L/min | ||
Tidal volume | upper limit setting range 100~1500ml | |
low limit setting range 0~1400ml | ||
Sustained high-pressure alarm | it will give alarm when stress have consistently been higher than 25 cmH2O |
|
Power | AC 220V±10% 50Hz±1Hz(UPS, Storage battery) | |
Mechanical Arms | ||
(End-expiratory CO2 monitoring) | ||
(Specific interface of waste anesthesia gas) | ||
*Items within brackets are optional. |
ICU Equipment | Lab equipment | Medical image | Medical Cold Chain |
anesthesia machine | Biochemistry Analyzer | Ultrasound system | BBR |
Medical ventilator | Hematology analyzer | X-ray | Deep freezer |