Product Description
5KW Mobile FPD Digital Surgical X-ray Machine 5KW
High Frequency C-Arm Fluoroscopy Electric Power Source
Product Introduction
This machine uses high-frequency high-voltage technology to convert the mains electricity into a constant high-voltage output. It makes the image clear and the human skin absorbs less dose. The flexible and movable body is easy to position and is more suitable for orthopedics, spinal surgery, orthopedics, trauma orthopedics and operating rooms. It can greatly improve the level of surgery and reduce the risk of surgery and the probability of complications.
Product Parameters
|
Voltage (V)
|
A0 220
|
Power (KW)
|
5
|
|
Vertical Movement
|
400mm (Electric)
|
Horizontal Movement
|
200mm
|
Horizontal Rotation
|
±180°
|
Arc Track Rotation
|
180°
|
Horizontal Swing
|
±22.5°
|
Aperture Distance
|
900mm
|
Arc Depth
|
540mm
|
Medical Combination High-Frequency X-Ray Source
|
Power Phase
|
Single Phase
|
Voltage Range
|
100VAC~240VAC
|
Frequency Range
|
50Hz/60Hz±1Hz
|
Nominal/Maximum Power
|
5kW/5kW
|
KV Range
|
40kV~125kV
|
KV Ripple Coefficient
|
≤3%@100kV
|
KV Rise Time
|
≤1ms@100kV (10%~90%)
|
KV Exposure Accuracy
|
±(5%+1kV)@<100kV;±5kV@≥100kV
|
MA Range
|
RAD:1~100mA
|
|
Continuous Fluoro:0.2~10mA
|
|
Pulsed Fluoro:0.2~100mA
|
KV Rise Time
|
≤1.5ms@63mA (10%~90%)
|
Exposure Tube Current Accuracy
|
±(5%+0.2mA)@≥10ms
|
|
±20%@<10ms
|
mAs Accuracy
|
±(5%+0.2mAs)@>5ms
|
Frames Per Second
|
± (10%+0.2mAs) @ ≤5ms
|
|
0.5/1/2/3/4/8/10/15/25/30
|
Exposure Time Range
|
RAD: 5ms~10000ms
|
|
Fluoro: Max 5 minutes
|
Exposure Time Accuracy
|
± (2%+1ms)
|
Automatic Tube Calibration
|
Yes
|
Function
|
1. kV-mA-ms
|
|
2. kV-mAs
|
Technology Selection
|
3. kV-mAs-ms
|
|
4. Continuous Fluoro
|
|
5. Pulsed Fluoro
|
Service Software
|
Yes
|
Filament Performance
|
20kHz±2kHz
|
|
Maximum Filament Current
|
|
5A
|
Communication
|
Analog
|
|
CAN2.0
|
|
RS232
|
Safety Requirements
|
Grounding Resistance
|
|
Insulation Withstand Voltage
|
|
1600VAC
|
|
Leakage Current to Ground
|
|
≤2.5mA
|
Tube Model
|
XD56-5/17
|
Nominal Focal Spot Size
|
0.3mm/0.6mm
|
Maximum Anode Heat Storage Capacity
|
150kJ
|
Anode Disk Target Angle
|
10°
|
MBK Performance
|
Maximum Anode Continuous Heat Dissipation
|
|
300W
|
|
MBK Heat Capacity
|
|
850kJ
|
|
Anode Type
|
|
Rotating
|
|
Additional Filtration
|
|
1mm Al
|
|
Corresponding Product Model
|
|
RC5B
|
Appearance
|
Size (LWH)
|
Control Box Size
|
330mm260mm129mm
|
Anode Box Size
|
260mm150mm62mm
|
MBK Size
|
350mm180mm210mm
|
Control Box Weight
|
6kg
|
MBK Weight
|
16.5±0.5kg
|
|
Model
|
CareView560RFZ
|
Flat Panel Type
|
1GZ0
|
Scintillator
|
Direct Growth Cesium Iodide
|
Imaging Area
|
227mm * 227mm
|
Pixel Size
|
148um
|
Pixel Matrix
|
1536 * 1536
|
A/D Conversion
|
16 bit (12bit optional)
|
Data Interface
|
Gigabit Ethernet
|
|
|
Detailed Photos
![5kw High Frequency Mobile Digital C-Arm X-ray Machine](//www.micstatic.com/athena/img/transparent.png)
![5kw High Frequency Mobile Digital C-Arm X-ray Machine](//www.micstatic.com/athena/img/transparent.png)
Company Profile