Overview

Basic Info.

Model NO.
YJ-C800
St Segment Range
-2.0 Mv + 2.0 Mv
Humidity
10%~90%
ECG
5 Leads: Ra, La, Ll Rl, V
Transport Package
Corton
Specification
175mm*210mm*80mm
Trademark
FORERMED
Origin
China
HS Code
8419200000
Production Capacity
3000pieces/Year

Product Description

Human Use CE Certification Touch Screen Patient Monitor
Product Description

YJ-C800 Multi-parameter Patient Monitor (12.1 inches)

Human Use CE Certification Touch Screen Patient Monitor
YJ-C800
patient monitor is designed to match the pace and unique needs of adult, pediatric, and neonatal intensive care; anesthesia and peri-operative care; OR and cardiac care environments. Pacemaker detection and Arrhythmia analysis..
Multi-parameter Patient Monitor:ECG. Sp02. NIBP. RESP. TEMP. PR.HR.
 
Display
12.1"real color TFT Screen
 
Enviroment
Operating environment:
Temperature: 0~40ºC
Humidity:15%~80%
Pressure :86.0 kPa~106.0 kPa
Transport and Storage environment:
Temperature: -20~55ºC
Humidity:10%~90%
Pressure:86.0 kPa~106.0 kPa
 
Power Requirements
AC: 100 ~240V.50Hz/60Hz
DC: Built-in rechargeable battery
Battery: 11.1V 24wh Li-ion Battery
2h operating after full charge
5min operating after low battery alarm
 
Dimension and Weight
Equipment:
340mm x 245mm x134 mm(about);
2.798kg(about)
Package:
380mm x350 mm x 300mm; 4.598 kg(about)

Application Range
• Adult/Pediatric/Neonatal/Medicines/ Surgery
• Operating Room/ICU/CCU

NIBP
Method:Oscillometry
Measure mode :Manual, Auto. STAT
Measure interval in auto mode:
1~5/10/15/30/60/90/120/180/240/480min
Measure period in STAT mode: 5min
Pulse rate range: 40- 240bpm
Measure & alam range:
Adult
SYS 40~280mmHg
DIA 10 ~220mmHg
MEAN 20 ~240mmHgl
Pediatric
SYS 40 ~220mmHg
DIA 10- 160mmHg
MEAN 20- 170mmHg
Neonatal
SYS 40~135mmHg
DIA 10 ~100mmHg
MEAN 20 ~100mmHg
Static pressure measurement
Range:0~ 300mmHg
Accuracy:±3mmHg
Resolution: 1mmHg Accuracy
Max. Mean Error ± 5mmHg
Max. Standard Deviation: 8mmHg
Overpressure protection:
Adult 300mmHg
Pediatric 240mmHg
Neonatal 150mmHg

SpO2
Measurement range: 0~100%
Resolution:1%
Accuracy.:70%- 100% ± 2%
40%~ 69% :±3%
 
Store & Reviewing
- ECG: 30 minutes one important lead's ECG waveform
- Alarm: 1800 groups Alarm events reviewing
- NIBP: 1000 groups NIBP measurement
- Arrhythmia: 128 groups data (8 seconds ECG waveforms) -Power
- off storage: 72 hours trend data & 1 ECG wave form(option)
 
IBP (option)
- Channel: 2
- Measurement Range: -50~+300mmHg
- Unit: mmHg, kPa
- Accuracy:±2mmHgor2%,whichever is greater
 
EtC02(option, Microstream)
- Range 0-19.7%(0-150 mmHg)
- Unit: %, mmHg: kP
- Respiration Rate Range 2-150 bpm
 
ECG
- Mode: 5-leads (standard); 3-leadsor 12-leads (option) -Lead selection
I,II,IH,aVR,aVL,aVF,V1-V6(option) -Gain:AUT0,0.25x,0.5x,1.0x,2.0x,4.0x
- Insulation Breakdown Voltage4000VAC 50/60Hz Sweep speed 6.25mm/ s,12.5mm/s,25mm/s,50mm/s
- HR Range: Adult: 10~300bpm Child & Neonate: 10~350bpm
- HRAccuracy ±1%or±1 bpm, whichever is greater
 
Date Storage
Trend diagram/table: 720h
NIBP review:10000 events
Wave review: 12h
Alarm review:200 alarm events
Suppert drug concentration titration analysis

 

ECG
5 Leads: RA, LA, LL RL, V
Lead mode: I,, ,m., AVR, AVL, AVF.V
Gain: x 1.25 mm/mV, 2.5 mm/mV.
5.0 mm/mV, 10 mm/mV,
20mm/mV (error 5%)
Sweep speed: 6.25mm/s.
12.5mm/s,25mm/s,50mm/s (error ≤ ± 10%)
Bandwidth: Surgery 1~25 Hz
Monitor 0.5~40 Hz
Diagnostic 0.05-130 Hz
Sensitivity: >200 μV P-P
CMRR: 112dB
Differential Input Impedance: >5M
ohm Electrode Offset Potential:±300mV
Polarization Voltage: ≥± 500mV
Input Impedance: 5 M
Calibration Voltage: 1 mV ± 5%


 
ST Segment
Application Range
ST Segment Range: -2.0 mV ~ + 2.0 mV
Accuracy:0.02 mV


 
Pulse Rate
Measure/alarm range: 20~300bpm
Resolution:1bpm
Accuracy :±3bpm


 
RESP
Method: impedance between RA-LL
Resp Impedance range: 0.3-3Ω
Base Impedance range: 200 Ω-4000 Ω
Bandwidth : 0.3 ~2.5Hz
Gain: x 0.25, x0.5, x1,x2 x4
Resp rate:
Measurement Range
Adult 0 ~ 120BrPM
Neonatal/Pediatric 0~150BrPM
Resoluition:1 BrPM
Accuray: 7~ 150BrPM ( ±2BrPM)
0 ~ 6BrPM(unspecified)
Apnea Alarm: 10- 40s


 
TEMP
Channel 2
Measure & alarm range: 0-50 ºC
Resolution: 0.1ºC
Accuracy (no sensor) : ±0.1ºC (0-50 ºC )


 
Standard accessories
NIBP cuff & tube
ECG cable & electrodes
SpO2 sensor
TEMP probe
Lithium-ion battery
Power cable
Operator's manual
 
Optional accessories
IBP
CO2
Nellcor SpO2


 
Alarm
- Three Level: Low, medium and high
- Indication: Auditory and visual
- Setup: Default and custom
- Silence: All alarms can be silenced
- Volume: 45-85 dB measured at 1 meter
Thermal Recorder (Option)
- Method: Thermal dot array
- Paper width:50 mm(1.97in)
- Paper Speed:12.5/25/50(mm/sec)
- Traces Maximum: 3 tracks

Related Products:
Human Use CE Certification Touch Screen Patient Monitor

Certifications

Human Use CE Certification Touch Screen Patient Monitor

Company Profile

Human Use CE Certification Touch Screen Patient Monitor

FAQ

Human Use CE Certification Touch Screen Patient Monitor

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now