Product Description
YJ-M32D Digital Medical X-ray Radiographic System
1. The equipment is used for digital medical X-ray radiography of all parts of the whole body bedside through electricity-assisted movement;
2. The equipment can be used in conjunction with a radiographic table and bucky stand to perform digital medical X-ray radiography on the chest, abdomen, limbs, spine and other parts, which is convenient, fast, flexible and accurate;
No. |
Product Name |
Quantity |
1 |
Flat Panel Detector 17″x17″ |
1 |
2 |
High Frequency Generator |
1 |
3 |
X-Ray Tube |
1 |
4 |
Collimator |
1 |
5 |
Mobile Stand |
1 |
6 |
Laptop Workstation |
1 |
7 |
Bucky Stand |
Optional |
8 |
Radiographic Table |
Optional |
1. Flat Panel Detector
Detector Technology: Wireless a-Si Flat Panel
Scintillator Material: CsI
Images Size: 17″x17″ inch
Static Pixel Matrix: 3072 x 3072pixels
Pixel Size: 139μm
Spatial Resolution: 3.5lp/mm
Output Grayscale: 16bit
Image Preview Time: 2s (wireless) / 1s (wire)
Battery Standby Time: 8h
Connection: Wireless / Wire
Power Supply: AC 100~240V, 50/60Hz, 20W
Resistant: IPX4
Dimensions: 460 x 460 x 15 mm
Weight: 4.3 kg
Operating Ambient Temperature: 5~35 °C
Operating Relative Humidity: 10~75 %
2. High Frequency Generator
. 32KW HF generator
. Nominal Output Power: 32kW
. Maximum Output Power: 35.2kW
. Inverter frequency: 60kHz~250kHz , max. 250khz
. kV Range: 40-125kV
. mA Range: 10-400mA
. mAs Range: 0.5-200mAs
. mS: 1mS~7.1S
. Plug in to use, input voltage 220 (110) V, input power 2KVA
3. X-ray tube
. Focus: 0.6/1.2mm
. Voltage: 150kV
. Anode Type: Rotating
. Anode Heat Capacity: 300kHU
. Anode Angle: 12°
4. Collimator
. Manual Control
. Filter: 1.2mm Al
. Collimator Rotation Range along the vertical axis: ±90°
. Tube head with 7 inch touch screen, LCD display with high voltage parameter adjustable
5. Mobile Stand
. Mobile Stand Size: 1200mm × 550mm × 1300 mm
. Weight: 220kg
. The column can lift up to 500mm distance with electric buttons
. The Vertical Movement Range of SID: 530~2050mm
. X-ray tube rotation: ±90°
. X-ray tube rotation around tube axis: -15° ~0° ~+90 °
6. Laptop Workstation
. Laptop Brand: Lenovo
. Display: 15 Inch
. CPU: 11th Generation Intel® Core™ i5 Processor
. Memory RAM: 8G
. Graphics card: 2 GB DDR3
. HDD: 500GB
. Image Acquisition: Automatic Window Adjustment, Automatic Cropping, Automatic Transmission
. Image Processing: Image correction, Image Flipping
7. Bucky Stand
Up and down movement range of the cassette along the column: 400mm-1850mm, with a deviation of not more than ±5%, and mechanical limit
Size dimensions of the cassette: 530x494x75mm
Able to clamp various models of flat panel detectors and cassette dimensions The grid can be installed on the side (498.5x449mm)
Overall height of the bucky stand column: 2060mm
Up and down movement handbrake, and hand-release automatic brake
8. Radiographic Table
. Longitudinal floating of the table surface: ±320mm
. Horizontal floating of the table surface: ±120mm
. Longitudinal floating of the under-table cassette: ±230mm
. The under-table cassette can be loaded with various specifications of cassettes and detectors
. Size dimensions: 2100mm (L) × 750mm (W) × 650mm (H)