Customization: | Available |
---|---|
Classification: | Imaging Diagnostic Equipment |
Type: | X Ray Equipment |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Best Price High Frequency 630mA Sleep Table Chest Dr Digital X-ray
General Features:
Configuration | Parameter | YJ-BW50 |
Generator | Input Voltage | Three Phrases 380V±10% |
Max Power | 50kW | |
kV Range | 40-150kV | |
mA Range | 0-630mA | |
Tube | Nominal Voltage | 40~150kV |
Focal Spot | 0.6/1.2mm | |
Anode Input Power | 50kW | |
Anode Speed | 2800rpm | |
Flat Bucky Table |
Size | 2000×760mm |
Longitudinal Movement | 230mm | |
Lateral Movement | 1100mm | |
Vertical Stroke of Tube | 960mm | |
Max Loading | 250kg | |
Wall Bucky Stand |
Vertical Stroke of Cassette | 1230mm |
Flat Panel Detector |
Scintillator | Csl |
Active Area | 17x17 inch or 14x17 inch | |
Pixel Pitch | 139 μm | |
Spatial Resolution | 3.6 lp/mm |
1 High Frequency Generator
1.1 Functions: Digital x-ray radigography, x-ray filter radiography, buck stand radiography, ARP and AEC.
1.2 Nominal electric power: 50 kW
1.3 Tube volate: 40kV~150kV
1.4 Tube current: 10mA~630mA
1.5 Time: 2ms~10s
1.6 mAs: 0.1mAs~630mAs
1.7 Working frequency: ≥400kHz
1.8 Control panel: LCD touch screen
2 X-ray Tube
2.1 Max. Tube voltage: 150kV
2.2 Focus:Small focus:0.6mm; Big focus:1.2mm
2.3 Anode input power: small focus 19kW, big focus 50kW
2.4 Target angle: 12°
2.5 Anode RPM:2800rpm
2.6 Heat capacity: 150kHU
3 Flat Panel Detector
3.1 GOS & Csl
3.2 Size: 35×43cm(14×17 inch)
3.3 Pixel: 140μm
3.4 Pixel matrix: 2560×3072
3.5 A/D conversion: 16Bit
4 Radiography Table
4.1 Size: 2100mm×825mm×655mm (LxWxH)
4.2 Horizontal moving range: ≥250mm;
4.3 Lengthways moving range: ≥825mm;
4.4 Table top lock: Electromagnetic lock, braking force≥100N, with pedal switch, flexible and convenient.
4.5 With electric or manual control of mechanical movement, and there is automatic tracking alignment function with the x-ray tube and the detector.
4.6 Grid size: ≥15"×18";Grid focus distance: f0=100cm; Grid ratio: r=10 :1;Grid density: N=103Lines/Inch
4.7 Tube Column
4.7.1 Secure and solid structure
4.7.2 Column rotation: ≥±180°
4.7.3 Moving range along the table: ≥1575mm, can be locked at any point
4.7.4 Tube moving up & down: 930mm±10mm, an be locked at any point
4.7.5 Tube rotation: ≥±180°
4.7.6 Max. Distance from tube focus to film: ≥1200mm.
5 Bucky Stand
5.1 Up & Down moving range: ≥1200mm;
5.2 At max. Height, the distance between the floor and the box center is ≥1500 mm;
5.3 Grid size: 18×18";Grid focus: f0=180cm;Grid ratio: r=10 :1;Grid density: N=103Lines/Inch
6 Collimator: Flexible and convenient to operate, and any rectangle radiography field size is available.