Customization: | Available |
---|---|
Classification: | Physiological Functions of Diagnosis and Monitoring Equipment |
Type: | Patient Monitor |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Body 12.1 inch high-brightness TFT LED Support display maximum 8 waveforms Support 6 channel ECG waveform display simultaneously Optional touch screen Stroage Support storage of 168 hours trend table and graph review 100 minutes waveform review 500 groups NIBP review 100 hours of parameter alarm events review and associated parameters Printer Built-in high-speed 50mm thermal printer (Brand: SEIKO, Japan) Central System Optional Build-in wireless network module, supporting wired or wireless connection to the central monitoring station. |
Alarm Three-level acousto-optic alarm Sensor-off alarm Paper out alarm Support alarm review Support alarm pause Operating System Multi-display mode to meet different clinical requirement, including standard interface, big font, OxyCRG, trend graph, NIBP review and full leads ECG interface. NIBP self-test mode: including overpressure test, static pressure test and air leakage test. 13 types of Arrhythmia analysis and real-time S-T segment analysis and pacemaker detection Drug calculation and titration table Support multi-language display Support online software upgrading by net |
Dimension and Weight - Dimension: 310mm*290mm*150mm - Weight: 3.4kg(excluding accessories) Power Supply - Voltage: AC100~240V, 50/60HZ, Power≤60W Display - 12.1" color TFT LED - Resolution: 800*600 pixels Battery (Pluggable) - Type: Rechargeable lithium battery 14.8V/2200mAh - Charge Cycle: ≥500 times - Working time: 2 hours (optional larger battery for 4-5 hours) Recorder (Option) - Method: Thermal printer - Paper width: 50 mm (1.97 in) - Printing speed: 25/ 50 mm/s - Trace: Max. 2 tracks - Recording way: Real-time Recording, Review Printing, Alarm Recording Alarm - Level: Low, medium and high - Indication: Auditory and visual - Alarm volume adjustable - Alarm pause time: 1min, 2min - Parameter alarm type: Latch/ Unlatch Input Device - Touch screen (option) - Knob (Standard) - Keypad input (Standard) System Output & Extensible Interface - Ethernet Network: 1 standard RJ45 socket Operating Environment - Temperature: 5 ~ 40 ºC - Humidity: 15% ~ 80% (non-condensing) - Atmosphere pressure: 86 KPa ~ 110 KPa Transportation and Storage Environment - Temperature: -20~50 ºC - Humidity: 10%~90% (non-condensing) - Atmosphere pressure: 86 KPa ~ 110 KPa Safety - IEC60601-1 Approved, CE marking according to MDD93/42/EEC - With reference to RoHS Directive 2011/65/EU recasting Trend & Reviewing - Trend: 168 hours - NIBP measurement reviewing: 500 groups - Waveform review: 100 minutes - Alarm event: 100hours of parameter alarms events and associated parameter SpO2 (Analog Technic) - Measurement Range: 0 ~ 100 % - Resolution: 1 % - Accuracy: ±2% (70% ~ 100%) Unspecified (0 ~ 69%) Pulse Rate - Measuring and Alarm Range: 20~300bpm - Accuracy: ±3% - Resolution: 1bpm N ellcor-SpO2 (Option) - Measurement Range: 0 ~ 100 % - Resolution: 1 % - Accuracy: 70% ~ 100%, ±2 % (adult) 70% ~ 100%, ±3 % (Neonate) 70% ~ 100%, ±2 % (Low Perfusion) 0% ~ 69%, unspecified Pulse Rate - Measurement range: 20 ~ 300 bpm - Resolution: 1bpm - Accuracy: ±3 bpm (20 ~ 250 bpm) Unspecified (251~300 bpm) IBP (Option) - Max Channel: 2 - Measurement way: Thermal resistance way - Press Sensor: Sensitivity 5 uV/V/mmHg, ±2% Impedance 300 to 3000Ω - Resolution: 1 mmHg - Unit: mmKg, kPa, cmH2O - Transducer sites: Arterial Pressure (ART) Pulmonary Arterial (PA) Left Arterial (LAP) Right Arterial (RAP) Central Venous Pressure (CVP) Intracranial Pressure (ICP) P1/ P2 - Measuring and alarm range: ART 0 ~ +350mmHg PA -10 ~ +120 mmHg CVP/ RAP/ LAP/ ICP -10 ~ +40 mmHg P1/ P2 -50 ~ +350mmHg - Accuracy: Static: ±1mmHg or ±2%, whichever is greater (exclusive of transducer) ±4mmHg or ±4%, whichever is greater (inclusive of transducer) Dynamic: ±4mmHg or ±4%, whichever is greater * Specifications subject to change without prior notice |
ECG - Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V - Gain: 2.5mm/mV(×0.25), 5.0mm/mV(×0.5), 10mm/mV (×1), 20mm/mV (×2), - Sweep speed: 12.5 mm/s, 25 mm/s, 50 mm/s - ECG signal range: ±6 mV - Accuracy: ±1bpm/ ±1%, whichever is greater - Resolution: 1 bpm - Leakage Current < 10 μA - Input impedance: > 5.0Mohm - CMRR: Diagnostic Mode >90 dB; Monitor Mode>100dB Surgery Mode>100dB - Baseline Recovery: ≤ 5s after defibrillation (Monitor or Surgery mode) - Bandwidth: Surgery 1 ~ 20Hz Monitor 0.5 ~ 40 Hz Diagnostic 0.05 ~ 130 Hz - Against electrosurgical interference and defibrillation - Indication of Electrode Separation: Every electrode (exclusive of RL) Heart Rate - Measure range: Adult: 0bpm; 15 ~ 300 bpm Neo/Ped: 0bpm; 15 ~ 350 bpm - Resolution: 1 bpm - Accuracy: ± 1% or ± 1bpm, whichever is greater ST Measurement - Range: -2.0 ~ +2.0 mV - Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, whichever is greater - Other range: unspecified Respiration - Method: Impedance between RA-LL, RA-LA - Gain: ×0.25, ×0.50, ×1, ×2, - Respiration Rate: 0bpm, 0 ~ 150 BrPM - Sweep speed: 6.25 mm/s, 12.5 mm/s, 25mm/s - Resolution: 1 BrPM - Accuracy: ±2 bpm or ±2%, whichever is greater - Apnea Alarm: 10 ~ 40 s NIBP - Method: Oscillometric - Measure mode: Manual, Auto, STAT - Measure Interval in AUTO Mode 1~480 min - STAT mode cycle time: Keep 5 minutes, at 5 seconds interval - Measure and Alarm Range: Adult: SYS: 40 ~ 270 mmHg DIA: 10 ~ 215mmHg MEAN: 20 ~ 235 mmHg Pediatric: SYS: 40 ~ 200 mmHg DIA: 10 ~ 150mmHg MEAN: 20 ~ 165 mmHg Neonate: SYS: 40 ~ 135 mmHg DIA: 10 ~ 100mmHg MEAN: 20 ~ 110 mmHg - Static pressure accuracy: ±3mmHg - Resolution: 1mmHg - Accuracy: Maximum Mean error ±5mmHg Maximum Standard deviation ≤8mmHg - Over pressure Protection: Dual protection via software & hardware Temperature - Technique: Thermistor probe (2.25K) - Channel: Dual-channel, provide T1; T2; ΔT - Measuring and Alarm Range: 0.0 ºC~ 50 ºC (32ºF~ 122ºF) - Unit: Celsius (ºC), Fahrenheit ( ºF) - Resolution: 0.1ºCor 1ºF - Accuracy: ±0.1ºC(exclusive probe) Mas imo SpO2 (Option) - - Measurement Range: 0 ~ 100 % - - Resolution: 1 % - Accuracy: 70% ~ 100%, ±2 % (adult/ pediatric, non-motion conditions) 70% ~ 100%, ±3 % (neonate, non-motion conditions) 70% ~ 100%, ±3 % (motion conditions) 0% ~ 69% unspecified Pulse Rate - Measurement range: 25 ~ 240 bpm - Resolution: 1bpm - Accuracy: ±3 bpm (non-motion condition) EtCO2 (Mainstream/ Sidestream) (Option) - Measure method: Non-dispersive infrared (NDIR) - Measure Range: 0 ~19.7% (0 ~ 150 mmHg) 0 ~ 20 kPa - Resolution: 0.1 mmHg - CO2 Accuracy: 0 ~ 40 mmHg, ±2 mmHg 41 ~ 70 mmHg, ±5% of reading 71 ~ 100 mmHg, ±8% of reading 101~ 150 mmHg, ±10% of reading at 760 mmHg, ambient temperature of 25ºC) - Respiratory Rate: Range: 3 ~150 BrPM Accuracy: ±1 bpm EtCO2 (Micro-stream) (Option) - Measure method: Non-dispersive infrared (NDIR) - Measure Range: 0 ~19.7% (0 ~150 mmHg) 0 ~ 20 kPa - Sample Rate: 50 mL/min ±10mL/min - Resolution: 0.1 mmHg (0 ~ 50 mmHg) 0.25 mmHg (50 ~ 114 mmHg) - CO2 Accuracy: 0 ~ 40 mmHg, ±2 mmHg 41 ~ 70 mmHg, ±5% of reading 71 ~ 100 mmHg, ±8% of reading 101~ 150 mmHg, ±10% of reading at 760 mmHg, ambient temperature of 35ºC) - Respiratory Rate: Range: 3 ~120 BrPM Accuracy: ±1 bpm |