Customization: | Available |
---|---|
Type: | Autoclave Steam Sterilizer |
Kind: | Autoclave Steam Sterilizer |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Equipment Type
|
vacuum steam autoclave sterilizer
|
Certificate
|
CE ISO9001 ISO13485
|
Machine size
|
1360*810*1580mm
|
Working temperature
|
121C - 134 C
|
Power supply
|
AC 380V , 50Hz
|
Working pressures
|
210kPa-230kPa (2.1-2.3Bar)
|
Space needed
|
the machine shell are removable , end wheels , 500 mm space from Autoclave are enough for maintenance
|
Safety over-pressure |
1.Over-pressure warning alarm 2. safe pressure relief valve 3. over-temperature heating shut-off device |
Safety door interlock
|
PLC set: the door can't open while vessel is under pressure; can't start up if the door is not properly closed
|
Safety emergency shut-off
|
Red Emergency button in a readily accessible location
|
Safety surfaces
|
Surfaces operator may contact NOT exceeding 50°C
|
Safety vacuum breaker
|
During a power outage or other failure the vacuum will stop ,and replace to the Atmosphere
|
Materials of construction
|
304 stainless steel
|
Pre-set operating cycles
|
Pre-set modes: naked instrument,fabric ,rubber ,high pressure
|
Pre-set leak testing
|
Pre-set BD test(Bowie Dick Type Test) for leak testing and vacuum pump diagnose.
|
Door
|
mechanical rotating locking with electronic sensor
|
Controls |
1. multiple pre-set operating cycles. 2. user setup ,possible for operator to alter pre-set cycle parameters/add new pre-set operating cycles |
|
3. system setup ,For purposes of maintenance, testing, or in cases of emergency. 4. The sterilizer protected against the effects of short circuit in inputs and outputs that are connected to the controller |
|
Display indicators |
door locked, operation in progress, major operating cycle stages, and cycle complete ,times ,temperature ,pressure ,fault condition readable by normal vision from a distance of 1.2 m |
|
Indicator for temperature
|
± 1% accuracy over the scale range 50°C to 150°C; 0.1°C resolution for digital display |
|
Indicator for pressure
|
± 1.6% over the scale range -0.6 bar to 3 bar; 0. 1kpa (0.001bar) resolution for digital display
|
|
Indicators for processing time
|
Error not to exceed 1%
|
|
Fault condition |
In the event of a failure of the automatic controls, or if a failure occurs that prevents the completion of the process, the controls screen show a visual indication of failure and an audible alarm |
|
Mini printer Recording
|
Recording of time, temperature and pressure include values during transition points throughout the operating cycle
|
|
Vacuum
|
-80Kpa ~ 90Kpa ( -0.8bar ~0.9 bar )
|
|
Decontamination of air
|
Air filter with activated carbon filtration, steam treatment to prevent release of pathogenic aerosols
|
|
Markings
|
Markings for safety and operation comply with EN 13445
|
|
Manuals |
English language. 1. Operation instructions (including process description), 2. Loading and maintenance procedures. 3. Short-form of operation and loading procedures. |
|
Spare parts(option) |
a. Heating element b. Door seal/gasket c. Replacement air filter d. Safety valve e. Pressure and temperature |