YJ-T8 High-End 2D ECHO Trolley Color Doppler Ultrasound machine
* Continuous wave Doppler lmaging(CW) * Anatomic 3 M Mode lmaging * Auto IMT(intima-media thickness)Measurement * 3D/4D Imaging * Trapezoidal lmaging &Panoramic lmaging * Speckle Noise Suppression |
Micron imaging technology Micron imaging technology, rea-time tracking of specificsignals at the edges of different tissues, to achieve edgeenhancement,and monitor each pixel at the same timeoptimize the intemal signal of the organization and perfecthintegrate the edge information and the internal pixelinformation of the organization to restore the real anddelicate excellent lavel contrast Two-dimensional image |
Harmonic imaging technology ( THl ) it improwes immage darity by improwing tissue contrast resolutianspatial resolution and eliminating near-field artifacts. It ismainly used for the dagnosis of cardiavascular and abdominaldiseases. it plays an important role in evaluating the lesionarea and boundary division of patients with imaging difficultiesThe technology has been fully approved by cllinicians. Harmonic technology retains the second harmonic signal tothe greatest extent based on removing the fundamentalsignal, which lincreases the signal strength by more than 30%compared with the traditianal signal processing. reducesnoise and artifacts, and improves the contrast resolution otissue images. |
Trapezoid imaging Trapezoid imaging is a kind of expanded imaging, whichis transformed into a trapezoid based on the originarectanglle, and the left and right sides are expanded to acertain extent, achieving a wider field of view. The principle of ultrasound imaging is to scan the humanbody with ultrasonic sound beams, and obtain images ofinternal organs by receiving and processing the reflectedsignals |
Automatic spectrum tracking measurement technology Ultrasound Doppler technology is used in the ultrasound system for examining the heartand arteries and veins. It is necessary to extract relevant parameters from the Dopplerspectrogram to evaluate the hemodynamic status of the heart and blood vessels. Thedisadvantage of manual detection is that the operator's marking of the peak velocity isrelatively monotonous and time-consuming, with poor repeatability and low estimationaccuracy; and during the detection, in order to mark the peak velocity, the operator needsto interrupt the acquisition of Doppler signals, which makes it impossible to estimate inreal time. This host contains an autoratic errvelope detection module, which can automatically track thetime-related changes of the peak blood flow velocity and average velocity, and displaythem in real time on the Doppler spectrogram. |
1: | Summary of main specifications and system of cart type color Doppler ultrasound |
1.1 | Trolley type all digital color Doppler ultrasonic mainframe |
1.2 | Ultrasonic host operating system: Windows operating system |
1.3 | Applications: Abdomen, obstetrics, gynecology, heart, urinary system, small organs, superficial, blood vessels, pediatrics, newborns, musculoskeletal |
1.4 | Probes: Convex probe, Tran-vaginal probe, Linear probe, Micro-convex probe, Cardiac probe,4D Volume probe |
1.5 | Applications and report: Abdominal,OB,GYN,Cardiac,Urinary,Small Parts,Superficial, Vascular, Pediatrics, Advanced measurement software packages, report software packages, case management software packages, etc. |
☆1.6 | carotid artery intima measurement thickness(IMT) |
☆1.7 | Automatic spectral envelope measurement |
1.8 | Full digital transmission and reception of beam synthesizer |
1.9 | Color Doppler imaging(C) |
1.10 | Pulse wave Doppler Imaging(PW) |
☆1.12 | Coherent Contrast imaging(CCI) |
1.12 | Continuous wave Doppler imaging(CW) |
☆1.13 | B/C/D Real-time three synchronous imaging |
☆1.14 | Power Doppler imaging(PDI) |
☆1.15 | Direct power Doppler imaging(DPDI) |
1.16 | M mode imaging |
☆1.17 | Anatomic M mode imaging |
☆1.18 | Color Doppler M mode imaging |
☆1.19 | Elastography |
☆1.20 | Tissue Doppler imaging(TDI) |
☆1.21 | Strain rate imaging (SRI) |
1.22 | Tissue harmonic imaging(THI) |
1.23 | Fusion harmonic imaging(FHI) |
1.24 | Speckle Reduce imaging(SRI) |
☆1.25 | Panoramic imaging |
☆1.26 | Deflection imaging |
☆1.27 | Trapezoidal imaging |
1.28 | Adaptive velocity optimization |
☆1.29 | Free hand 3D |
1.30 | Real time 3D imaging(3D/4D) |
1.31 | DICOM3.0 |
1.32 | Monitor:≥21.5 inch,high definition ultrasonic display |
1.33 | ≥13.3 inch touch screen |
1.34 | Physical clipboard: save the image on the left side of the screen, which can be directly saved or deleted. |
1.35 | The system has the function of on-the-spot upgrade |
1.36 | Presupposition: for different inspection of the viscera, preset the inspection conditions for the best image, reduce the adjustment of the operation, and the commonly used external adjustment and combination regulation. |
1.37 | Probe interface: 4 |
1.38 | Chinese and English System, Chinese and English input, optional |
1.39 | Depth:≥360mm; |
1.40 | Extended imaging |
1.41 | Support 10 kinds of language: CH, EN, FR.SP,PT.RU and etc |
2: | Probes |
2.1 Convex probe | Fundamental Frequency:2.0MHz/2.5MHz/3.5MHz/4.0MHz/5.0MHz/6.0MHz/8.0MHz/9.0MHz/10MHz Harmonic Frequency: 4.0MHz/4.6MHz/5.0MHz, |
2.2 Linear probe |
Fundamental Frequency:4.0MHz/4.6MHz/5.0MHz/6.0MHz/7.0MHz/8.0MHz/9.2MHz/10.0MHz/12.0MHz/13.3 MHz, Harmonic Frequency: 8.0MHz/9.2MHz/10.0MHz, |
2.3 Trans-vaginal probe | Fundamental Frequency: 3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz/10.0MHz, Harmonic Frequency: 6.0MHz/7.0MHz/8.0MHz, |
2.4 Micro-convex probe | Fundamental Frequency: 3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz, Harmonic Frequency: 6.0MHz/7.0MHz/8.0MHz, |
2.5 Cardiac probe | Fundamental Frequency:1.7MHz/1.9MHz/2.1MHz/2.5MHz/3.0MHz/3.4MHz/3.8MHz/4.2MHz/5.0MHz, Harmonic Frequency: 3.4MHz/3.8MHz/4.2MHz, |
2.6 4D Volume probe |
Fundamental Frequency: 2.0MHz/2.5MHz/3.0MHz/3.3 MHz/3.7MHz/4.0MHz/5.0MHz/6.0MHz, Harmonic Frequency: 4.0MHz/5.0MHz/6.0MHz, |
3: | 2D imaging mode |
3.1 | Gain:0-100,Step 2 adjustable |
3.2 | TGC:8 segment adjustable |
3.3 | Maximum focus point:≥7, which can be moved throughout the whole process. |
3.4 | Speckle reduction:0-5,5 level |
3.5 | Space Synthesis:0-2,2 level(Liner probe: 3 level, cardiac probe:0) |
3.6 | Dynamic:30-300,35 level,step 5 adjustable |
3.7 | Line density:low,middle,high,3 level |
3.8 | Frame correlation:0-4,4 level |
3.9 | Noise reduction:0-5,5 level |
3.10 | Edge Enhancement:0-5,5 level |
3.11 | Sound power:2-10, 9 level |
3.12 | Grey scale:0-67, 67 level |
3.13 | False color:0-67,67 level |
3.14 | Image style:Soft-Comparison,2 level |
The screen has real-time display of voice power, probe frequency, dynamic range, pseudo color, gray scale and other 11 parameters can be adjusted | |
4: | Color Doppler imaging mode |
4.1 | Blood gain:0-100,Step 2 |
4.2 | Parameter display:Velocity,Variance |
4.3 | B-Restrain(B/W restrain):0-7, 7 level |
4.4 | Speed Through:0-8, 8 level |
4.5 | Sampling number:6-24, 7 level |
4.6 | Blood flow preferred:0-8, 8 level |
4.7 | Filtering:1-6, 6 level |
4.8 | Sound power:2-6, 4 level |
4.9 | Noise reduction:0-4, 4 level |
4.10 | Smooth treatment:0-4, 4 level |
4.11 | Frame correlation:0-6, 6 level |
4.12 | Chromatography(Blood flow graph):0-37, 37 level |
4.13 | Line density:Low-Middle-High, 3 level |
4.14 | Frequency:4 level adjustable |
4.15 | Velocity:Minimum 0.4K,Maximum 40.5K Convex probe:0.4K-4.3K-38.5K Linear probe:0.4K-14.7K-39.0K Trans-vaginal probe:0.4K-7.8K-39.7K Volume probe:0.4K-4.2K-34.8K Micro-convex probe:0.4K-10.3K-40.5K cardiac probe:0.4K-7.8K-39.7K |
PS:The frequency of the probe changes and the frequency value changes | |
PS:Frame rate changes with speed | |
5: | Pulse wave Doppler(PW) |
1 | Gain:0-100,Step 2 |
5.2 | Spectrum envelope function: real time automatic spectrum envelope, manual spectrum envelope, and other modes. The system automatically analyses and displays various data such as PSV, EDV, RI, PI, S/D, ACC, HR and so on. Can wake up or close |
5.3 | Sample volume:0.5mm~30mm |
5.4 | Blood angel:-75-75 degree,Step 5 |
5.5 | False color:0-67, 67 level |
5.6 | Dynamic range:20-40, 4 level |
5.7 | Filter:0-9, 9 level |
5.8 | Smooth treatment:1-4, 4 level |
5.9 | Sound power:2-5, 4 level |
5.10 | Volume:0-100, 10 level,Step 10 |
5.11 | Audio filtering:0-4, 4 level |
5.12 | Base line:-1.0~1.0, |
5.13 | Grey map:0-67, 67 level |
5.14 | Scan velocity:100-500, 6 level |
5.15 | PRF:Minimum 0.5K,Maximum 87.5K Convex probe:0.5K-4.3K-63.3K Linear probe:0.5K-14.5K-78.4K Trans-vaginal probe:0.5K-8.1K-78.4K Volume probe:0.5K-4.2K-53.8K Micro-convex probe:0.5K-10.3K-81.1K cardiac probe:0.5K-4.3K-87.5K |
5.16 | Frequency:4 level |
PS:The frequency of the probe changes and the PRF value changes | |
PS:The frequency of the probe changes and the frequency value changes | |
6: | Continuous Wave Doppler(CW) |
6.1 | Support probe:Cardiac probe |
6.2 | Adjustment of B mode parameters is switchable |
6.3 | Gain:0-100,Step 2 |
6.4 | Sampling line position is adjustable |
6.5 | PRF:0.9K~36.1K |
6.6 | Baseline:-1.0~1.0 |
6.7 | Blood angel:-75~75 degree |
6.8 | Grey map:0-67 |
6.9 | Scan velocity:100-300 |
6.10 | False color:0-67 |
6.11 | Dynamic range:20-40 |
6.12 | Filtering:0-9,9 level |
6.13 | Smooth treatment:1-4 |
6.14 | Frequency:2.0MHz/2.3 MHz/2.5MHz/3.0MHz,4 level adjustable |
6.15 | Sound power:2-5 |
6.16 | Volume:0-100 |
6.17 | Audio Filtering:0-4 |
☆7: | Anatomical M imaging |
7.1 | Support probe:Convex probe, Linear probe,Cardiac probe |
7.2 | Adjustment of B mode parameters is switchable |
7.3 | Gain:0-100,Step 2 |
7.4 | M Sampling line angel is adjustable |
7.5 | M Sampling line length is adjustable |
7.6 | Sampling line:3,Can be displayed or hidden separately |
☆8: | Blood flow M model(MC) |
8.1 | Adjustment of B mode parameters is switchable |
8.2 | Gain:0-100,Step2 |
8.3 | MC Sampling line angel is adjustable |
8.4 | MC Sampling line length is adjustable |
8.5 | Frequency:4 level |
8.6 | Sampling number:6-24 |
8.7 | Speed through:0-8, 8 level |
8.8 | Scan velocity:150-500 |
8.9 | Frame correlation:0-6, 6 level |
8.10 | Filtering:1-6,6 level |
8.11 | Blood flow preferred:0-8,8 level |
8.12 | Smooth treatment:0-4,4 level |
8.13 | Map:0-37, 37 level |
☆9: | Elastography |
9.1 | Adjustment of B mode parameters is switchable |
9.2 | Gain:0-100,Step 2 |
9.3 | B/E,Double real-time display on the same screen |
9.4 | Probe displacement curve display:Up/Down |
9.5 | Pressure indicator bar display |
9.6 | Frequency:8-9 level,Adjustable;According to the probe display |
9.7 | Noise reduction:0-2, 2 level |
9.8 | Frame correlation:0-3, 3 level |
9.9 | Comparison:0-13, 13 level |
9.10 | False color:0-3, 3 level |
9.11 | Don't support cardiac probe |
☆10: | Tissue Doppler imaging(TDI) |
10.1 | Support probe: Cardiac probe |
10.2 | Adjustment of B mode parameters is switchable |
10.3 | Gain:0-100,step 2 |
10.4 | ROI area adjustable |
10.5 | Sampling number:6-24 |
10.6 | Velocity:0.4K-8.0K |
10.7 | Frame correlation:0-6,6 Level |
10.8 | Tissue preferred:0-7, 7 level |
10.9 | Frequency:2.0MHz/2.3 MHz/2.5MHz/3.0MHz |
10.10 | Support color reversal |
☆11: | Strain rate imaging |
11.1 | Support probe: Cardiac probe |
11.2 | Adjustment of B mode parameters is switchable |
11.3 | ROI area adjustable |
11.4 | Gain:0-100,Step 2 |
11.5 | Sampling number:6-24,6 level |
11.6 | Axial average:1-4, 4 level |
11.7 | Velocity:0.4K-8K |
11.8 | Frame correlation:0-6, 6 level |
11.9 | Tissue optimization:0-7,7 level |
☆12: | Panoramic imaging |
12.1 | Support probe:Linear probe |
12.2 | Speckle Reduction:0-5, 5 level |
☆13: | Deflection imaging |
13.1 | Support probe:Linear probe |
13.2 | Adjustment of B mode parameters is switchable |
13.3 | Deflection angel:8 level |
13.4 | Speckle reduction:0-5, 5 level |
13.5 | Dynamic rate:30-180,Step 5 |
13.6 | Line density:low-middle-high,3 level |
13.7 | Frame Correlation:0-4, 4 level |
13.8 | False color:0-67, 67 level |
13.9 | Image style:Soft-Comparison,2 level |
13.10 | Noise reduction:0-5, 5 level |
13.11 | Edge Enhancement:0-5,5 level |
13.12 | Sound power:2-10,8 level |
13.13 | Grey map:0-67,67 level |
☆14: | Trapezoidal imaging |
14.1 | Probe support:linear probe |
14.2 | Adjustment of B mode parameters is switchable |
14.3 | Deflection angel:8 level |
14.4 | Speckle reduction:0-5, 5 level |
14.5 | Dynamic rate:30-180,Step 5 |
14.6 | Line density:low-middle-high,3 level |
14.7 | Frame Correlation:0-4, 4 level |
14.8 | False color:0-67, 67 level |
14.9 | Image style:Soft-Comparison,2 level |
14.10 | Noise reduction:0-5, 5 level |
14.11 | Edge Enhancement:0-5,5 level |
14.12 | Sound power:2-10,8 level |
14.13 | Grey map:0-67, 67 level |
14.14 | Space Synthesis:0-2, 2 level |
☆15 | Freehand 3D imaging |
15.1 | Support probe:convex probe, linear probe |
15.2 | Display model: 4 pictures |
15.3 | Image Rotation X/Y/Z Axis |
15.4 | Multi-slice Visibility |
16 | Real-time 4D imaging |
16.1 | Support probe: 4D volume probe |
16.2 | Adjustment of B mode parameters is switchable |
16.3 | Gain:0-100,Step 2 |
16.4 | Display model:one image,two images,four images |
16.5 | Image Rotation:X/Y/Z Axis |
16.6 | Multi-slice Visibility |
16.7 | Light&Shade inversion |
16.8 | Smooth:0-4, 4 level |
16.9 | Threshold level:0-129, Step 3 |
16.10 | Transparency:1-509,Step 10 |
16.11 | Render type:4 kinds,Surface,maximum,minimum,perspective |
17: | Extended Imaging |
17.1 | Gain:0-100,Step 2 |
17.2 | TGC:8 segment adjustable |
17.3 | Maximum focus point:≥7, which can be moved throughout the whole process. |
17.4 | Speckle reduction:0-5,5 level |
17.5 | Space Compound:0-2,2 level(Linear probe: 3 level,don't support cardiac probe) |
17.6 | Dynamic range:30-180,35 level,Step 5 |
17.7 | Line density:Low,Middle,High,3 level |
17.8 | Frame correlation:0-4,4 level |
17.9 | Noise reduction:0-5,5 level |
17.10 | Edge enhancement:0-5,5 level |
17.11 | Sound power:2-10, 9 level |
17.12 | Grey map:0-67, 67 level |
17.13 | False color:0-67,67 level |
17.14 | Image style:Soft-Comparison,2 level |
17.15 | Extended level: Maximum 72 level Convex probe:9 level Trans-vaginal probe:72 level Micro-convex probe:29 level Cardiac probe:40 level 4D Volume probe:17 level |
PS:The screen has real-time display of voice power, probe frequency, dynamic range, pseudo color, gray scale and other 11 parameters can be adjusted | |
PS: When the probe scan range reaches the maximum, the space synthesized is 0. | |
18: | Measurement and analysis function: |
18.1 | General measurement: Distance, area, ellipse, cross line, angle, distance ratio, volume, Volume (ellipse), area ratio, diameter, joint angle |
18.2 | Cardiac:Automatic spectrum envelope,LV,Main Pulmonary artery diameter,RVEDd,RVEDs,LVM,LAV,HR,MVF,AO,AR,LVOT,TVF,Pulmonic valve,Pulmonary vein,RV,Doppler fetal heart sound,LVET,LVM,LVMI,AV |
18.3 | Vascular: carotid intima (IMT), length stenosis ratio, area stenosis ratio, IMT (back wall), IMT (front wall) |
18.4 | OB:Fetal routine,AFI,TW,GS,CRl,OFD,HL,ulna,NT,Fibula,Nbonel,Radial,Tibia |
18.5 | GYN:uterus,cervix,corpus uteri/cervix uterus,left ovarian vein,right ovarian vein,dominant follicle,intima thickness |
18.6 | Urology: prostate,residual urine,left kidney,right kidney,left suprarenal vein,right suprarenal,left testis,right testis,left seminal vesicle,right seminal vesicle |
18.7 | Abdomen:liver,CHD,partal vein diameter,cholecyst, pancreas,spleen, Internal diameter of abdominal aorta, kidney |
18.8 | Small parts:Thyroid |
18.9 | Software package:Measurement package,Software package,Medical records management software package |
19: | Graphic and text management system |
19.1 | Host build in 2 hard disk(SSD 120+1T),Start fast and stable |
19.2 | Movie playback:≥1200 frames |
19.3 | Internal file information management system: can record patient number, name, check number, check date and so on, and can be searched and managed by numbering, checking number, name and so on. |
19.4 | Type of report is 16 |
19.5 | One key fast report graphic and text management |
20: | Interface |
20.1 | USB interface: 4 |
20.2 | HDMI interface: 1 |
20.3 | RJ-45 interface:1 |
20.4 | Grounding wire interface:1 |
20.5 | DVD RW:1 |
21: | Configuration |
21.1 | Trolley type full digital color Doppler ultrasound diagnostic system |
21.2 | Probe: convex array probe (standard), linear probe (optional), Trans-vaginal probe (optional), cardiac probe (optional), 4D volume probe (optional) |
21.3 | ≥13 quick adjusting knobs |
22: | Technology, after-sales service and other requirements |
22.1 | After acceptance, the warranty is free for two years(Provide manufacturer warranty certificate) |
22.2 | Manufacturer has ISO13485 certification and EU CE certification. |