Dry Eye Analyzer Ophthalmic Eye Exam Instrument Ophthalmoscope Ocular Surface

Product Details
Customization: Available
Classification: Imaging Diagnostic Equipment
Type: Dry Eye Analyzer

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 14001, QC 080000, ISO 13485, EICC
International Commercial Terms(Incoterms)
FOB, CIF, CFR
  • Dry Eye Analyzer Ophthalmic Eye Exam Instrument Ophthalmoscope Ocular Surface
  • Dry Eye Analyzer Ophthalmic Eye Exam Instrument Ophthalmoscope Ocular Surface
  • Dry Eye Analyzer Ophthalmic Eye Exam Instrument Ophthalmoscope Ocular Surface
  • Dry Eye Analyzer Ophthalmic Eye Exam Instrument Ophthalmoscope Ocular Surface
  • Dry Eye Analyzer Ophthalmic Eye Exam Instrument Ophthalmoscope Ocular Surface
  • Dry Eye Analyzer Ophthalmic Eye Exam Instrument Ophthalmoscope Ocular Surface
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
YJ-OS113
Certification
CE, ISO13485
Name
Infrared Dry Eye Ocular Surface Analyzer
Questionnaire
3 Type
Gland Opening
HD Eyelid Image
Weight
15.5kg
Size
492mm*280mm*476mm
Material
Metal
Transport Package
Cartons
Specification
910*760*900
Trademark
FORERMED
Origin
China
HS Code
9018129100
Production Capacity
800 Unit/Month

Product Description

Dry Eye Analyzer Ophthalmic Eye Exam Instrument Ophthalmoscope Ocular Surface

Product Description

 

Dry Eye Analyzer Ophthalmic Eye Exam Instrument Ophthalmoscope Ocular Surface
Dry Eye Analyzer Ophthalmic Eye Exam Instrument Ophthalmoscope Ocular Surface

Features:
1. Support 7 ways of dry eye detection functions to provide reliable basis for clinical diagnosis
2. A full set of dry eye examinations can be completed in 7 minutes, effectively improving clinic efficiency
3. The test report with pictures and texts, the test results shown clearly and in detail
4.Fully automated software analysis + Quantification of testing standards, easier diagnosis by doctors
5.Convenient patient management system, which can continuously record the development of patients
6.Non-invasive inspection method, safer operation, patient comfort and easy cooperation


Dry Eye Analyzer Ophthalmic Eye Exam Instrument Ophthalmoscope Ocular Surface
TMH
Comfortable and reliable
Using infrared light with a wavelength of 850um as the light source, it will not stimulate the secretion of tears, the patient is more comfortable and the result is more reliable.
Automatic identification, identification, measurement.

 
Ocular Redness Analysis

Conjunctiva, sclera, two modes
Multi-dimensional analysis of the patient's ocular surface hyperaemia
Provide more evidence for diagnosis Automatic identification, analysis, and classification
 
Dcular Redness Analysis

Conjunctiva, sclera, two modes
Multi-dimensional analysis of the patient's ocular surface hyperaemia
Provide more evidence for diagnosis Automatic identification, analysis, and classification
 
Corneal Staining

Professional yellow filter
Professionally designed yellow filter
Make comeal fluorescein sodium stained image clearer
Automatic identification, analysis, classification

Dry Eye Analyzer Ophthalmic Eye Exam Instrument Ophthalmoscope Ocular Surface
NIBUT

Comfortable and reliable
The use of infrared rays with a wavelength of 850μm will not stimulate tear secretion, and record the maintenance time of the tear film in the original state of the eye, and the result is more reliable. All-round
Provides first and average break-up time, tear film break- up diagram, and graph to display the situation of tear fim break in all round.

Lipid Layer Analysis
High precision
The white ring projection can completely present the true color and shape of the lipid layer.
Automatic identification, analysis, and classification Using professional Al algorithm, lipid layer thickness measurement can be accurate to 10nm.

 
Lipid Layer Analysis
High precision
The white ring projection can completely present the true color and shape of the lipid layer.
Automatic identification, analysis, and classification Using professional Al algorithm, lipid layer thickness measurement can be accurate to 10nm.
 
Meibomian Gland Imaging Analysis
Clear
Professional infrared imaging can clearly observe the morphology of the meibomian acini Al image enhancement

Dry eye project inspection report
Rich in content, 7 items of dry eye examination data are fully displayed on one report.
Be clear at a glance, Sufficient image and data combination , clear and detailed display of inspection results.
Multiple templates, Support single report, any combination of multiple projects.

 

Dry Eye Analyzer Ophthalmic Eye Exam Instrument Ophthalmoscope Ocular Surface
 

Detailed Photos

Dry Eye Analyzer Ophthalmic Eye Exam Instrument Ophthalmoscope Ocular SurfaceDry Eye Analyzer Ophthalmic Eye Exam Instrument Ophthalmoscope Ocular SurfaceDry Eye Analyzer Ophthalmic Eye Exam Instrument Ophthalmoscope Ocular SurfaceDry Eye Analyzer Ophthalmic Eye Exam Instrument Ophthalmoscope Ocular Surface

Company Profile

Dry Eye Analyzer Ophthalmic Eye Exam Instrument Ophthalmoscope Ocular SurfaceDry Eye Analyzer Ophthalmic Eye Exam Instrument Ophthalmoscope Ocular SurfaceDry Eye Analyzer Ophthalmic Eye Exam Instrument Ophthalmoscope Ocular SurfaceDry Eye Analyzer Ophthalmic Eye Exam Instrument Ophthalmoscope Ocular SurfaceDry Eye Analyzer Ophthalmic Eye Exam Instrument Ophthalmoscope Ocular SurfaceDry Eye Analyzer Ophthalmic Eye Exam Instrument Ophthalmoscope Ocular Surface

 

FAQ

Dry Eye Analyzer Ophthalmic Eye Exam Instrument Ophthalmoscope Ocular Surface

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More