• China Supply CE Approved 12.1 Inches Multi-Parameter Patient Monitor
  • China Supply CE Approved 12.1 Inches Multi-Parameter Patient Monitor
  • China Supply CE Approved 12.1 Inches Multi-Parameter Patient Monitor
  • China Supply CE Approved 12.1 Inches Multi-Parameter Patient Monitor
  • China Supply CE Approved 12.1 Inches Multi-Parameter Patient Monitor
  • China Supply CE Approved 12.1 Inches Multi-Parameter Patient Monitor

China Supply CE Approved 12.1 Inches Multi-Parameter Patient Monitor

Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Patient Monitor
Certification: CE, FDA, ISO13485
Group: Adult; Pediatric; Neonate
Product Name: Patient Monitor
Model: Yj-F5c
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Trading Company
  • Overview
  • Product Description
  • Technical specifications
  • Company Profile
  • Certifications
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
YJ-F5C
Application
Hospital
Certificate
CE
Display
12.1inches LED
Printer
Built-in High-Speed 50mm Thermal Printer
Alarm
Three-Level Acousto-Optic Alarm
Power Supply
AC100-240V, 50/60Hz, Power≤60W
Battery
Rechargeable Lithium Battery 14.8V/2200mAh
Dimension
298mm*272mm*122mm
Weight
2.5 Kg (Excluding Accessories)
Transport Package
Standard Carton
Specification
31cm*29cm*15cm
Trademark
FORERMED
Origin
China
HS Code
8419200000
Production Capacity
1000 Units/Month

Product Description

China Supply CE Approved 12.1 Inches Multi-Parameter Patient Monitor

Product Description

YJ-F5C Multi-parameter Patient Monitor (12.1 inches)
China Supply CE Approved 12.1 Inches Multi-Parameter Patient Monitor

     Features
Core
•Classic ARM9 main board based on embedded Linux
•Support storage of 720 hours trend table and graphreview, 2 hours waveform review, 1000 groups NIBPreview and 200 alarm events review

Body
12.1inch high resolution LCD
•Support display max. 11 waveforms
•Support 7 channel ECG waveform display simultaneously

Printer
•Built-in high-speed 50mm thermal printer

Central System
•Wired or wireless connection
•Bed view

Alarm
•Three-level acousto-optic alarm
Human voice alarm
•Sensor-off alarm
•Paper out alarm
•Support alarm review
•Support alarm pause

Linux OS
•Support data export for EMR connectivity by USB
Multi-display mode
NIBP self-test mode
•Support Data Export by USB
•13 types of Arrhythmia analysis and real-time S-T segment analysis and pacemaker detection
Drug calculation and titration table
Hemodynamic calculation
Multi-language display                                                

Technical specifications

Model Configuration

Standard Configuration 12.1-inch LED, 3/5 Lead ECG, NIBP, SpO2, Pulse Rate, Temperature, Respiration
Optional Configuration 2-Temperature, 1/2 IBP, EtCO2, Masimo SpO2, Nellcor SpO2, Bed View
Optional Accessories Touch Screen, Printer, Central Monitoring Station, Neo/Ped Accessories, Wall-mounting, Trolley

 Performance Specifications
 

Dimension and Weight
- Dimension: 298mm*272mm*122mm
- Weight: 2.5 kg (excluding accessories)

Power Supply
- Voltage: AC100~240V, 50/60HZ, Power≤60W

Display
- 12.1" color TFT LED resolution: 800*600 pixels

Battery
- Type: Rechargeable lithium battery 14.8V/2200mAh
- Charge Cycle: ≥500 times
- Working time: 3.5 hours

Recorder (Option)
- Method: Thermal printer
- Paper width: 50 mm (1.97 in)
- Printing speed: 12.5/25/ 50 mm/s
- Trace: Max. 3 tracks
- Recording way: Real-time Recording, Review Printing,
                            Periodic Recording, Alarm Recording

Alarm
- Level: Low, medium and high
- Indication: Auditory and visual
- Alarm volume adjustable
- Alarm pause time: 2min
- Parameter alarm type: Latch/ Unlatch

Input Device
- Standard: Knob /Keypress
- Option: Touch screen

System Output & Extensible Interface
- Ethernet Network: standard RJ45 socket * 1pc
- USB Port: 1pc

Operating Environment
- Temperature: 5 ~ 40 ºC
- Humidity: 15% ~ 90% (non-condensing)
- Atmosphere pressure: 86 KPa ~ 110 KPa

Transportation and Storage
- Temperature: -20~50 ºC
- Humidity: 10%~90% (non-condensing)
- Atmosphere pressure: 86 KPa ~ 110 KPa

Safety
- IEC60601-1 Approved, CE marking according to MDD93/42/EEC
- With reference to RoHS Directive 2011/65/EU recasting

Trend & Reviewing
- Trend: 720 hours
- ARR events: 128 groups of ARR events and associated waveform
- NIBP measurement reviewing: 1000 groups
- Waveform review: 2 hours
- Alarm event: 200 alarms events review

SpO2
- Measurement Range: 0 ~ 100 %
- Resolution: 1 %
- Accuracy: ±2% (70% ~ 100%)
                  Unspecified (0% ~ 69%)
- Support Pitch tone and multi-level volume
- User-selectable waveform speed: 12.5, 25 mm/s
- PI range (Option):0.075%-20%

Pulse Rate
- Measuring and Alarm Range: 20~250bpm
- Accuracy: ±3 bpm
- Resolution: 1bpm
Respiration
- Method: Impedance between RA-LL, RA-LA
- Gain: ×0.25, ×0.50, ×1, ×2, ×4
- Respiration Rate: Adult 0 ~ 120 BrPM
                               Neonatal / Pediatric 0 ~ 150 BrPM
- Sweep speed: 6.25 mm/s, 12.5 mm/s, 25mm/s
- Resolution: 1 BrPM
- Accuracy:
               ±2BrPM or ±2% whichever is greater (7~150BrPM)
               Unspecified (0%~ 6BrPM)
- Apnea Alarm: 10 ~ 40 s

Temperature
- Technique: Thermistor probe (2.25K)
- Channel: Dual-channel, provide T1; T2; ΔT
- Measuring and Alarm Range: 0.0 ºC~ 50 ºC (32ºF~ 122ºF)
- Unit: Celsius (ºC), Fahrenheit ( ºF)
- Resolution: 0.1ºCor 1ºF
- Accuracy:
               no sensor ± 0.1ºC(25ºC - 45ºC) ,± 0.2ºC(other)
               include sensor ± 0.2ºC(32ºC - 42ºC)± 0.3ºC(other)

ECG
- Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V
- Protection: Breakdown Voltage 4000VAC 50/60Hz; Defibrillator proof

- Gain: 2.5mm/mV(×0.25), 5.0mm/mV(×0.5), 10mm/mV (×1), 20mm/mV (×2)

- Sweep speed: 12.5mm/s, 25mm/s, 50mm/s
- ECG signal range: ±5 mV p-p
- Accuracy: ±1%
- Resolution: 1 bpm
- Leakage Current < 10 μA
- Baseline Recovery:
≤ 3s after defibrillation
- Bandwidth: Surgery 1 ~ 20Hz
                     Monitor 0.5 ~ 40 Hz
                     Diagnostic 0.05 ~ 130 Hz
- Indication of Electrode Separation: Every electrode (exclusive of RL)

Heart Rate
- Measure range: Adult: 15 ~ 300 bpm
                            Neo/Ped: 15 ~ 350 bpm
- Resolution: 1 bpm
- Accuracy: ± 1%

ST Measurement
- Range: -2.0 ~ +2.0 mV
- Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, whichever is greater, other range: unspecified

NIBP
- Method: Oscillometric
- Measure mode: Manual, Auto, STAT
- Measure Interval in AUTO Mode
1,2,3,4,5,10,15,30,60,90,120,180,240,480 min
- STAT mode cycle time: 5 minutes
- Measure and Alarm Range:
                                        Adult: SYS: 40 ~ 280 mmHg
                                                 DIA: 10 ~ 220 mmHg
                                                 MEAN: 20 ~ 240 mmHg
                                      Pediatric: SYS: 40 ~ 220 mmHg
                                                  DIA: 10 ~ 160 mmHg
                                                  MEAN: 20 ~ 170 mmHg
                                      Neonate: SYS: 30 ~ 135 mmHg
                                                   DIA: 10 ~ 110 mmHg
                                                   MEAN: 20 ~ 110 mmHg
- Static pressure accuracy: ±3mmHg
- Resolution: 1mmHg
- Accuracy: Maximum Mean error ±5mmHg
                   Maximum Standard deviation ≤8mmHg
- Over pressure Protection: Dual protection
EtCO2 (Mainstream/ Sidestream) (Option)
- Measure method: Non-dispersive infrared (NDIR)

- Measure Range: 0 ~19.7% (0 ~ 150 mmHg)
                              0 ~ 20 kPa

- Resolution: 0.1 mmHg

- CO2 Accuracy:
                      0 ~ 40 mmHg, ±2 mmHg
                     41 ~ 70 mmHg, ±5% of reading
                     71 ~ 100 mmHg, ±8% of reading
                     101~ 150 mmHg, ±10% of reading
at 760 mmHg, ambient temperature of 25ºC)

- Respiratory Rate: Range: 3 ~150 BrPM
                               Accuracy: ±1 bpm

EtCO2 (Micro-stream) (Option)
- Measure method: Non-dispersive infrared (NDIR)

- Measure Range: 0 ~19.7% (0 ~150 mmHg)
                              0 ~ 20 kPa

- Sample Rate: 50 mL/min ±10mL/min
- Resolution: 0.1 mmHg (0 ~ 50 mmHg)
                     0.25 mmHg (50 ~ 114 mmHg)

- CO2 Accuracy:
                      0 ~ 40 mmHg, ±2 mmHg
                     41 ~ 70 mmHg, ±5% of reading
                     71 ~ 100 mmHg, ±8% of reading
                     101~ 150 mmHg, ±10% of reading
at 760 mmHg, ambient temperature of 35ºC)

- Respiratory Rate: Range: 3 ~120 BrPM
                               Accuracy: ±1 bpm

IBP (Option)
- Max Channel: 2
- Measurement way: Thermal resistance way
- Press Sensor: Sensitivity 5 uV/V/mmHg, ±2%
                          Impedance 300 to 3000Ω

- Resolution: 1 mmHg
- Unit: mmKg, kPa, cmH2O
- Transducer sites:
                         Arterial Pressure (ART)
                         Pulmonary Arterial (PA)
                         Left Arterial (LAP)
                         Right Arterial (RAP)
                         Central Venous Pressure (CVP)
                         Intracranial Pressure (ICP)
                         P1/ P2

- Measuring and alarm range:
              ART 0 ~ +350mmHg
              PA -10 ~ +120 mmHg
              CVP/ RAP/ LAP/ ICP -10 ~ +40 mmHg
              P1/ P2 -50 ~ +350mmHg

- Accuracy:
        Static:
                   ±1mmHg or ±2%, whichever is greater (exclusive of transducer)
                   ±4mmHg or ±4%, whichever is greater (inclusive of transducer)

Dynamic: ±4mmHg or ±4%, whichever is greater

* Specifications subject to change without prior notice
Company Profile

 

China Supply CE Approved 12.1 Inches Multi-Parameter Patient MonitorChina Supply CE Approved 12.1 Inches Multi-Parameter Patient Monitor
Certifications

 

China Supply CE Approved 12.1 Inches Multi-Parameter Patient Monitor
Packaging & Shipping

China Supply CE Approved 12.1 Inches Multi-Parameter Patient Monitor

FAQ